Records from 2016 to 2026. Most recent: inspection, 26 January 2026.
Inspection history · 12
26 January 2026
Internal Structural Exam · Administrative Inspection · Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8302451
24 January 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8069525
22 January 2024
Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7852718
18 January 2023
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7623028
24 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7457498
28 January 2022
Drydock Exam · Examination of Repairs · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7386211
14 January 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7123750
23 January 2020
Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6888193
11 April 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6665130
23 January 2018
COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6341212
22 February 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6090543
14 January 2016
Annual Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5800291
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 January 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel had expired contents in kit. Renew expired contents.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 25 February 2026
Resolution: O/O procured new asprin. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 January 2026
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List;
(4) Tide tables; and
(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Provide proof of missing pubs to the marine inspectors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 26 February 2026
Resolution: MI was provided proof of documents. All SAT.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 January 2026
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Place monthly inspection into vessel logs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 26 February 2026
Resolution: MI was provided vessels new logs showing change. All SAT.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 January 2026
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Place monthly inspection into vessel logs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 26 February 2026
Resolution: MI was provided new logs showing change. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel had 01 child life jacket that was not repairable. Replace life jacket with in-kind approved life jacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 25 February 2026
Resolution: O/O replaced 01 child lifejacket. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 January 2026
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Attach a clip to the line and mount light close to ring buoy. Attach line around the body of the ring buoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 25 February 2026
Resolution: O/O installed new ring buoy with clip. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2026
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Install valve on fuel line and properly label IAW regulation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 26 February 2026
Resolution: MI was provided proof labeling has been installed for system. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Store adult and child life jackets separately.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 25 February 2026
Resolution: O/O stored lifejackets seperately. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 January 2026
Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except:(1) On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: (iii) Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches).
Install line or netting under the rail courses to meet the requirement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2026
Resolved 25 February 2026
Resolution: O/O installed netting on both sides of the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 January 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. Vessels all around white light was improperly installed and has been replaced with a clip on all around white. Corrected on the spot.
46 CFR 183.420
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 31 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2021
Resolved
The number of child size life jackets must equal at least 10% of number of persons permitted. Two child lifejackets were found unsatisfactory. Replace life jackets. Vessel isrestricted to one passenger weighing less than 90lbs until life jackets replaced. Total passenger count remains 20.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 20 January 2021
Resolution: Satisfactory evidence provided. Restrictions removed for child passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2021
Resolved
Each ring life buoy must be stowed in a way that can be rapidly cast loose. Ring life buoy is secured with a bungee cord. Mount properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 20 January 2021
Resolution: Proper mount installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 January 2021
Resolved
Mounted at the operating station, emergency instructions shall be posted. Emergency instructions did not contain instructions for heavy weather. Post heavy weather instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 14 January 2021
Resolution: Heavy weather instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Replace 05 life jackets. Passenger count will be amended to 30 until life jackets replaced.
Action required: 10 - Deficiency Rectified
Due 23 January 2020
Resolved 23 January 2020
Resolution: Deficiency rectified on the spot. 05 new life jackets on board.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 23 January 2020
Resolved
Must have emergency instructions mounted at the operating station. Mount emergency instructions at operating station.
Action required: 705 - Other - as specified
Due 23 January 2020
Resolved 23 January 2020
Resolution: Deficiency rectified on the spot. Instructions mounted at operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2020
Resolved
Water light must be approved IAW with 161.010 in subchapter Q. Replace expired battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 25 January 2020
Resolution: Replaced battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2020
Resolved
Each ring life bouy on a vessel must be approved IAW with 160.050 in subchapter Q. Replace wasted retro tape on life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 25 January 2020
Resolution: Replaced retro tape on ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2020
Resolved
Connection must be made to battery terminals with permanent type connectors. Replace wing nuts with permanent type connectors.
Action required: 10 - Deficiency Rectified
Due 23 February 2020
Resolved 23 January 2020
Resolution: Deficiency rectified on the spot. Permanent connectors used for terminals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2020
Resolved
Each vessel must be equiped eith at least 02 portable battery lights. Replace broken flash light.
Action required: 10 - Deficiency Rectified
Due 23 February 2020
Resolved 23 January 2020
Resolution: Deficiency rectified on the spot. 02 portable flashlights provided for vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 April 2019
Resolved
Bilge pump and alarm switches are not permanently mounted in bilge well. A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) provided that the pump is permanently mounted. Permanently mount bilge pump and alarm switches to meet electric bilge pump installation requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 15 April 2019
Resolution: Master provided photos of bracket, hardware and permanent installation of bilge pump and float switches.
Documentation › Logs/Records › Drug Test Records
Issued 23 January 2018
Resolved
02 deck hands pre-employment testing results/exemptions not received prior to work in a safey sensitive position. Testing in progress.
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 5 February 2018
Resolution: Appropriate APCA paperwork received via e-mail.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 22 February 2017
Resolved
46CFR182.410(b) Repair renew Engine RPM Gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 27 February 2017
Resolution: Owner provided picture of RPM Gauge operational.