MAURY USCG vessel records Sign in
← All vessels

MISS TRISH

MISS TRISH is a 2002 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2002, most recently in August 2025, along with 6 deficiencies.

Records from 2002 to 2025. Most recent: inspection, 14 August 2025.

Built
2002
Last inspected
14 August 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

560176
Flag
UNITED STATES
—
Maury page id
psix-560176

Inspections, by type

Years with a record 15 calendar years (2002–2025)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

14 August 2025 Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8209785
24 February 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8083887
20 February 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7867485
16 February 2023 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7637875
3 March 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7397491
12 February 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7140026
19 February 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6903978
9 January 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6608182
21 February 2018 Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6351856
6 March 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6097826
22 February 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5817286
27 September 2011 Simplified Stability Test · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4150121
23 August 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4125016
17 February 2011 Annual Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943402
25 February 2010 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3682460
20 February 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3418857
22 February 2008 Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3149618
26 March 2002 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1597582

Deficiency record · 6

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 March 2025 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. - Records were requested by the Coast Guard and the employer was unable to provide them.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 15 April 2025
Resolution: The company sent negative drug tests for enough covered crewmembers to be in compliance with the CFR.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 March 2025 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. - The Master did not have a medical certificate when his MMC was reviewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 15 April 2025
Resolution: The captian who was with us during the inspection sent us his new medical certificate, showing he is in compliance with the CFRs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2018 Resolved
Found frayed wire in lead power line. Replace or repair to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 26 February 2018
Resolution: Operator removed section of damaged wire, reinstalled and emailed picture of repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2018 Resolved
Found multiple wires (4) connected to positive battery terminal, creating a potential fire hazard. No evidence of in-line fuses. Correct to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 7 March 2018
Resolution: Inspected new installation of MARPAC switch/fuse panel and associated wiring from battery. All SAT, required vessel rep to submit electrical system drawing and equipment specifications; All SAT.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 March 2017 Resolved
Owner or operator shall provide 03 approved, serviceable child size PFD's.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2017
Resolved 7 March 2017
Resolution: Owner provided 3 new child size type I PFD's.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 March 2017 Resolved
Owner or operator shall label emergency fuel shut off and make persons onboard aware of location and operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 7 March 2017
Resolution: Owner labeled emergency fuel shut off, and will make people on board aware.

Ownership record