Behind this panel: 11 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
14 August 2025
Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8209785
24 February 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8083887
20 February 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7867485
16 February 2023
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7637875
3 March 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7397491
12 February 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7140026
19 February 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6903978
9 January 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6608182
21 February 2018
Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6351856
6 March 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6097826
22 February 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5817286
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 March 2025
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. - Records were requested by the Coast Guard and the employer was unable to provide them.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 15 April 2025
Resolution: The company sent negative drug tests for enough covered crewmembers to be in compliance with the CFR.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 March 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. - The Master did not have a medical certificate when his MMC was reviewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 15 April 2025
Resolution: The captian who was with us during the inspection sent us his new medical certificate, showing he is in compliance with the CFRs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2018
Resolved
Found frayed wire in lead power line. Replace or repair to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 26 February 2018
Resolution: Operator removed section of damaged wire, reinstalled and emailed picture of repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2018
Resolved
Found multiple wires (4) connected to positive battery terminal, creating a potential fire hazard. No evidence of in-line fuses. Correct to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 7 March 2018
Resolution: Inspected new installation of MARPAC switch/fuse panel and associated wiring from battery. All SAT, required vessel rep to submit electrical system drawing and equipment specifications; All SAT.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 March 2017
Resolved
Owner or operator shall provide 03 approved, serviceable child size PFD's.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2017
Resolved 7 March 2017
Resolution: Owner provided 3 new child size type I PFD's.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 March 2017
Resolved
Owner or operator shall label emergency fuel shut off and make persons onboard aware of location and operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 7 March 2017
Resolution: Owner labeled emergency fuel shut off, and will make people on board aware.