Documentation record
Registered dimensions (L × B × D)42.6 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNO RECORD · YOUNGS CREEK, VA, UNITED STATES · built 1911
Hull materialWood
PropulsionSail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portREEDVILLE, VA
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Regulatory (Subpart C or D), Gross Ton
6 - Regulatory (Subpart C or D), Net Ton
15 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
11 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8283424
25 June 2025
Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8162069
31 July 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7971790
10 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7893844
20 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7719224
7 November 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7595984
20 July 2022
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7512265
3 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7466213
6 November 2020
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7094019
29 October 2020
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7084488
1 October 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7070231
17 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7059215
14 August 2019
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6780817
15 November 2018
Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6577928
29 January 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6345724
7 December 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6317404
27 July 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6216436
25 June 2017
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6186996
27 December 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6062864
20 November 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6054791
8 November 2016
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6045869
26 May 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5880325
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2025
Resolved
The OCMI may require that a vessel undergo any additional tests or inspection. Vessels Sail PMP requires an annual aloft inspection prior to vessel operation. Aloft inspection has not been completed.
46CFR176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2025
Resolution: Received photographic evidence the aloft inspection was completed.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 25 June 2025
Resolved
When in accordance with 176.210, a vessel must be provided with a stability letter. The access panel in the collision bulkhead is not installed. The access panel in the aft amidships bulkhead is not installed.
46CFR176.306
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2025
Resolution: Received photographic evidence the access panels were installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2025
Resolved
Vessel must carry either a first-aid kit that meets the requirements of 46CFR199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit is missing items, and some items are expired.
46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 15 July 2025
Resolution: Received photographic evidence the First Aid Kit was updated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 April 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was unable to complete drydock due to extensive repairs and rail availability. Credit drydock to be completed prior to carrying passengers.
46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
Resolution: Vessel completed outstanding worklist items and underway portion of the DD/ISE.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 April 2024
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel must complete annual inspection prior to carrying passengers.
46CFR176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
Resolution: Vessel completed COI Renewal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2023
Resolved
A vessel must be provided with a a satisfactory arrangement for draining any watertight compartment. Midship compartment (ballast compartment) installed bilge pump didn't pump water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2023
Resolution: Witnessed operation of midships compartment bilge pump, pumping water overboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 June 2023
Resolved
All vessels must have navigation lights in compliance with the applicable navigation rules. Vessel missing the anchor light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2023
Resolution: Witnessed operation of anchor light.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 June 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date navigation charts. Vessels charts are from 2022, and not corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 21 July 2023
Resolution: Vessel provided new (July 2023) navigation charts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2022
Resolved
Clean out and re-pack all identified areas on hull and internal planking.
Action required: 705 - Other - as specified
Due 7 November 2022
Resolved 6 February 2023
Resolution: Replaced/renewed caulking
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2022
Resolved
Repair port side rub rail.
Action required: 705 - Other - as specified
Due 7 November 2022
Resolved 6 February 2023
Resolution: Repaired rubrail
02 - Structural Conditions › N/A - No Subsystem › Triangle mark
Issued 7 November 2022
Resolved
Repair stbd side aft railing.
Action required: 705 - Other - as specified
Due 7 November 2022
Resolved 6 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2022
Resolved
An adult lifejacket must be provided for each person carried on board the vessel. Found 01 adult lifejacket unservicable. Limited to 24 persons on board.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2022
Resolved 17 June 2022
Resolution: Master provided evidence of a purchsed approved lifejacket for the vessel.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 September 2020
Resolved
46CFR182.530(a): On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel midship bilge high level alarm did not have an audio alarm and the visual indication stayed on always.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2020
Resolution: Witnessed proper operation of midship bilge high level alarm.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 December 2017
Resolved
Observed electrical cables being supported by plastic zipties. Install metal suppports for cables not mroe than 24 inches apart.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 January 2018
Resolved 29 January 2018
Resolution: Operator installed metal supports for cabling not more than 24 inches apart to replace the plastic zipties.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 December 2017
Resolved
Battery terminal connections were made using wing nuts. Remake battery terminal connections using permanent type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 January 2018
Resolved 28 December 2017
Resolution: Battery terminal connections were remade with permanent connections using a nut at each terminal.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 December 2017
Resolved
Observed the port and starboard navigation sidelights’ cabling not suitably supported and protected. Install metal coverings and secure to prevent mechanical damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2018
Resolved 28 December 2017
Resolution: The port and starboard navigation sidelights' cables were provided additional support utilizing hose clamps
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 25 June 2017
Resolved
Push boat engine will not start. Verify repairs and proper function of the engine to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2017
Resolved 27 July 2017
Resolution: Engine's electric starter solenoid was replaced. Inspected engine and electric starter; all sat. Engine started and operated as normal. Got underway for inspection; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 November 2016
Resolved
Water light battery is expired. Replace as new.
Due 8 December 2016
Resolved 20 November 2016
Engineering › Fuel Oil Service System › Gauge
Issued 8 November 2016
Resolved
RPM gauge inoperable. Repair or replace.
Due 22 December 2016
Resolved 27 December 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 November 2016
Resolved
B-II fire extinguisher is overdue. Replace or service to the satisfaction of a marine inspector.
Due 8 December 2016
Resolved 20 November 2016