Records from 2003 to 2025. Most recent: inspection, 29 August 2025.
Documentation record
Registered dimensions (L × B × D)71.5 ft × 21.1 ft × 5.3 ft
Registered tonnagegross 67 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINETTE MARINE CORP · MARINETTE, WI, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Simplified, Gross Ton
53 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
29 August 2025
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8220651
31 July 2025
Hull Examination · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8195490
28 May 2025
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8146761
10 April 2025
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8109473
29 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7903620
21 June 2023
Hull Examination · Deficiency Check · Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7719593
24 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7695174
15 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7478082
26 April 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7183467
20 May 2020
Administrative Inspection · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6956772
10 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6558295
26 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6456873
17 May 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5894077
24 April 2014
Deficiency Check · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4843091
3 May 2013
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586239
12 April 2012
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4287955
13 June 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4062252
18 April 2011
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3979722
21 March 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3975963
23 March 2010
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701467
14 March 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2602628
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978367
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 31 July 2025
Resolved
An internal structural examination required by this part may be conducted while the vessel is afloat or while it is out of the water. Forward most side voids on port and starboard sides both holed in same location - aft bulkhead inboard at base of circular structure just below void opening. Operator to provide repair proposal and affect permanent repairs.
46 CFR 137.330
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 6 August 2025
Resolution: Accepted photos of repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2024
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The vessel's fuel shutoff valve was not operable.
46 CFR 143.260(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 6 May 2024
Resolution: Verified operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. The vessel's RACOR fuel filters for vessel's generators were missing heat shields.
46 CFR 142.220
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 6 May 2024
Resolution: Verified installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2020
Resolved
The propulsion control system required by 143.225 must be designed so that, in the event of a single failure of any component of the system, propeller speed and direction of thrust are maintained or reduced to zero. Test the propulsion control in accordance with the manufacturer’s instructions in the presence of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 June 2020
Resolution: Verified engines were installed in accordance with manufacturer instructions
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 October 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 June 2020
Resolution: Verified proper AIS display
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010