NIGHT FLIGHT is a 1973 passenger vessel (uninspected). The Coast Guard has recorded 8 inspections since 2002, most recently in July 2009, along with 5 deficiencies.
Records from 2002 to 2009. Most recent: inspection, 16 July 2009.
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for NIGHT FLIGHT (ON 1125233), retrieved 18 September 2026. mauryrecords.com/v/psix-560241.html
Documentation record
Registered dimensions (L × B × D)35.9 ft × 12.9 ft × 6.7 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARVER BOAT CORPORATION · PULASKI, WI, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionNot recorded
Hull shapeShip
Hull configurationMonohull
Hailing portADELL, WI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Net Ton 20 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
16 July 2009Uninspected Passenger Vessel
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3572459
4 June 2007Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2951325
13 June 2006Uninspected Passenger Vessel
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2759413
25 May 2005Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2375896
12 July 2004Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2130472
3 May 2003Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1760791
23 July 2002Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1651024
18 May 2002Uninspected Passenger Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1623377
Electrical › Electrical Distribution System (service)
Issued 18 May 2002Resolved
PORT ENGINE HAS UNCONNECTED WIRES AT THE FRONT AND BACK OF INTAKE MANIFOLD AREAS. THEY NEED TO BE CONNECTED TO SOMETHING OR REMOVED LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Resolved 26 August 2002
Resolution: Corrected, see activity #1651024
Engineering › Fuel Oil Storage/Transfer System
Issued 18 May 2002Resolved
PORT ENGINE FUEL SHUT OFF VALVE IS INOPERABLE LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 August 2002
Resolution: Corrected, see activity #1651024
Engineering › Gasoline Engine (propulsion)
Issued 18 May 2002Resolved
STARBOARD ALTERNATOR IS BROKEN AND MISSING A PIECE. LEGACY COMPONENT DESC: Alternator (4 cycle)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 26 August 2002
Resolution: Corrected, see activity #1651024
Engineering › Steering Gear System
Issued 18 May 2002Resolved
MAIN STEERING STRUT BUSHING IS WORN ELONGATED AND ABOUT TO BREAK. THE STRUT THREADED ROD IS BENT EXCESSIVE. LEGACY COMPONENT DESC: Rudder Stock
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 26 August 2002
Resolution: Corrected, see activity #1651024
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 May 2002Resolved
5 PFD'S HAVE DAMAGED AND INOPERABLE LIGHTS. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 August 2002
Resolution: Corrected, see activity #1651024