Records from 2002 to 2026. Most recent: inspection, 30 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
30 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8418755
25 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8275806
28 October 2025
COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8251519
5 June 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8152578
6 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7975370
1 July 2024
In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7942343
14 February 2024
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7865378
31 October 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7818102
6 July 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7733926
19 April 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7433932
24 February 2022
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7392617
6 April 2021
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7169449
6 February 2020
DAPI Audit · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6904167
9 August 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6783120
6 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6705257
22 May 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6422636
27 February 2018
Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6361872
2 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6137444
4 January 2016
DAPI Audit · Drydock Exam · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5799459
3 May 2012
Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4295662
5 December 2011
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4200215
8 December 2010
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3872246
7 October 2008
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3327443
5 May 2008
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3200774
17 January 2007
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2857595
25 August 2006
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2755131
25 April 2006
Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2632808
10 November 2004
In-Service Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2246225
10 August 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2146688
29 April 2004
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2057206
23 July 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1849259
23 July 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1653473
28 June 2002
Hull Examination · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1598223
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 June 2025
Resolved
Marine employers whos vessel is involved in a marine casualty shall comply with 46CFR4.06. Vessel missing 02 alcohol swabs. Vessel restricted to operating within 02 hours of a testing facility. 46CFR185.212
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2025
Resolution: O/O procured 02 in-date alcohol test swabs and placed in service on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 11 adult lifejackets taken out of service - vessel restricted 22 adult passengers. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2022
Resolution: Bret (O/O) got six new lifejackets onboard.
Navigation › Piloting/Steering › Marine Charts
Issued 5 December 2011
Resolved
Provide an up to date chart for area navigated IAW 46 CFR 184.420.
Due 12 December 2011
Resolved 6 December 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 December 2011
Resolved
Repair/Replace anchor light IAW 46 CFR 183.420.
Due 12 December 2011
Resolved 6 December 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 December 2011
Resolved
Remark lifejacket storage to reflect current passenger count IAW 46 CFR 185.604(f).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2011
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 December 2011
Resolved
Replace deteriorated fuel hose for the port propulsion engine IAW 46 CFR 182.720.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 December 2011
Resolved
Replace the waterlight for the ring lifebuoy IAW 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2011
Lifesaving › Hand Flares › Not on Board
Issued 8 December 2010
Resolved
Provide additional flares on board to be IAW 46CFR180.68. 04 red hand flares were on board during inspection. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2010
Lifesaving › Lifebuoys › Serviceable
Issued 8 December 2010
Resolved
Repair/replace ring life buoy IAW 46CFR180.70. Line around the buoy is sun damaged. Shall be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2010
Resolved
Provide ammonia inhalants for first aid kit IAW 46CFR184.710. Shall be completed prior to 26DEC10.
Action required: 705 - Other - as specified
Due 26 December 2010
Resolved 30 December 2010
Lifesaving › Lifebuoys › Stowage
Issued 7 October 2008
Resolved
Stowage ring lifebuoy
Due 12 October 2008
Resolved 14 October 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 October 2008
Resolved
Replace items in first aid kit
Due 12 October 2008
Resolved 14 October 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 October 2008
Resolved
Repair bilge high level alarm and mark switches
Due 12 October 2008
Resolved 14 October 2008
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 25 August 2006
Resolved
Make permanent repairs to the Port side fuel tank grounding connector.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2006
Resolved
Properly repair gel coat gouge on port side forward side of hull.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2006
Resolved
Properly repair port bow FRB damage.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2006
Resolved
Properly repair starboard stern cleat improper patch.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Engineering › Bilge Water Management System › Not Installed
Issued 25 April 2006
Resolved
Renew all broken bilge access port covers.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2006
Resolved
Seal up fracture on engine mount transom.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 25 April 2006
Resolved
Dewater both hulls.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 November 2004
Resolved
Provide evidence of employee coverage as well as EAP training materials.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2004
Resolved 16 November 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 November 2004
Resolved
Provide rail courses with openings no greater than 4" IAW 46CFR177.900
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2004
Resolved 16 November 2004
Resolution: Installed netting around entire vsl.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 10 November 2004
Resolved
provide valid state commercial registration
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 6 December 2004
Resolution: RCVD
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 November 2004
Resolved
Pay user fee for vsl.
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 16 November 2004
Resolution: Rcvd copy of check
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 10 November 2004
Resolved
Relocate B-II extinguisher
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 16 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 10 November 2004
Resolved
Provide quicker access to PFD's stored in overheard canvas.
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 16 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 November 2004
Resolved
Provide one additional child size type one PFD.
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 16 November 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 10 November 2004
Resolved
Provide service on both B-II extinguishers, appears evident that one had been discharged.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2004
Resolved 16 November 2004
Resolution: serviced
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 10 November 2004
Resolved
Place holding tank valve in Holding tank position vice overboard.
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 16 November 2004
Engineering › Bilge Water Management System › Not Operational
Issued 10 August 2004
Resolved
Prove proper operation of port side high bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2004
Resolution: Visited vessel and witnessed satisfactory test of high bilge alarm. Apparent cause was that the float switch was inoperative. Float switch was replaced with a new unit.
Engineering › Bilge Water Management System › Pump
Issued 10 August 2004
Resolved
Prove proper operation of port side automatic bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2004
Resolution: Visited vessel and witnessed satisfactory test of automatic pump by pumping water into the space. Apparent cause was a broken wire. Wire was replaced.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 August 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 10 September 2004
Resolved 16 August 2004
Resolution: Received fax copy of certificate confirming enrollment of [name withheld] through calendar year 2004.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 August 2004
Resolved
Prove proper operation of deck lights.
Due 10 September 2004
Resolved 11 August 2004
Resolution: Visited vessel and observed that lights are working properly. The apparent reason for the failure was that a wire had been disconnected at the control console.