MAURY USCG vessel records
← All vessels

STRETCH DUCK 19

STRETCH DUCK 19 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in August 2019, along with 3 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 August 2019
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

560409
Flag
UNITED STATES
Maury page id
psix-560409

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

11 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788025
25 April 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6670236
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622654
9 January 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6607865
29 October 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6570477
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519696
21 March 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6388113
27 November 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6302817
13 September 2016 Administrative Inspection · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5999988
12 May 2016 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5875628
24 March 2016 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5840039

Deficiency record · 3

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new Conditions of Operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Bilge Water Management System › Piping
Issued 21 March 2018 No resolution recorded
Bilge piping and GPM rate is not in compliance with MSC Letter E1-0504811. Vessel to operate with 2 total hand bilge pumps and will require manning as appropriate. This is to be corrected by 2019 operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2018 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Pump
Issued 12 May 2016 Resolved
Primary fuel pump on the vessel failed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2016
Resolved 13 May 2016
Resolution: Received email notification that the primary fuel pump onboard the SD-19 has been replaced with a new unit. In/out of water operational test complete. Test SAT.

Ownership record