MAURY USCG vessel records Sign in
← All vessels

SUNBELT SPIRIT

SUNBELT SPIRIT is a 2002 freight ship. The Coast Guard has recorded 38 inspections since 2002, most recently in April 2023, along with 11 deficiencies and 3 operational controls.

Records from 2002 to 2023. Most recent: inspection, 14 April 2023.

Built
2002
Last inspected
14 April 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9233246 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
561210
Flag
MARSHALL ISLANDS
—
Maury page id
psix-561210

Inspections, by type

…with no type recorded7
Years with a record 15 calendar years (2002–2023)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17950 - Dead Weight, Metric Ton
60587 - Convention (Subpart B), Gross Ton
23315 - Convention (Subpart B), Net Ton
35670 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

14 April 2023 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7660372
11 March 2020 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6922239
22 January 2020 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6893854
31 January 2019 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6614634
3 January 2018 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6331077
20 December 2016 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6060321
20 February 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5860544
16 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5815906
29 December 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5788282
26 December 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4214048
5 February 2009 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3412770
28 November 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3370540
28 November 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3372715
28 October 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3353036
2 October 2008 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3334866
2 November 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3092044
28 September 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3068515
24 September 2007 PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3064891
19 September 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3061616
2 June 2007 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2943846
1 April 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2899274
20 June 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2680685
24 May 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2657664
24 May 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2658270
10 May 2006 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2645561
30 September 2005 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2504518
3 August 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2450041
21 June 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2397892
16 May 2005 PII Safety Exam · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2358926
29 September 2004 NPV Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2209153
4 August 2004 ISPS II Exam · NPV Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2142414
25 June 2004 ISPS III Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2108322
5 January 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1974687
2 July 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1834140
23 February 2003 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1748345
4 November 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1701259
20 April 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1607498
14 April 2002 Ballast Water Examination · Deficiency Check · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1601237

Deficiency record · 11

Lifesaving › Inflatable Liferafts › Float Free
Issued 20 December 2016 Resolved
3 of 4 inflatable liferafts were discovered to be improperly installed and were not float free. Deficiency was corrected on the spot. SOLAS 14 III/20.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2016
Resolved 20 December 2016
Resolution: Inflatable liferafts were properly rigged.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 December 2015 Resolved
The engine room's elevator shaft Class "A-60" bulkhead thermal insulation adjacent the evelator door was noted with several areas of wastage.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 January 2016
Resolved 9 February 2016
Resolution: Received Class Survey verifying repairs
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 November 2008 Resolved
Vessel granted Letter of Dispensation for one time voyage between Jacksonville, FL and Newark, NJ. Vessel sailing short one engineering watch officer due to marine casualty. See activity 3370540 for more details.
Action required: 15 - Rectify deficiencies by next port
Due 8 December 2008
Resolved 7 December 2008
Resolution: Received Class NK survey record no. 08NY0290 attesting to restoration of "M0" (Unmanned Machinery Space). See attachment.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 October 2008 Resolved
According to the Minimum Safe Manning Certificate. The vessel is required a third officer. Current third officer does not have a Valid Marshall Island (MI) endorsement or Receipt of Application. Vessel does not meet minimum manning.
Action required: 705 - Other - as specified
Resolved 2 October 2008
Resolution: Vessel received RoA prior to PSCO''s departure
Construction/Loadline › Hull › Bracket
Issued 29 September 2008 Resolved
While completing the hull walk of the ship, PSCO found a crack in the hull, located on the starboard side up forward. The crack is underneath the forward most cargo door/ramp. Appears to be in area designed for drainage in the cargo door.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2008
Resolved 28 October 2008
Resolution: Received class report stating that fracture has been drilled and welded to the satisfaction of class.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 24 September 2007 Resolved
The vessel is missing one 15 person life raft from the port side leaving a total of 4 on board. Records indicate the raft has been missing since before the March shipyard period and a class survey performed on 24 May 2007 indicates vessel to have a total of 5 rafts. Vessel is acquiring a new life raft in next port call of LA/LB.
Action required: 705 - Other - as specified
Resolved 26 September 2007
Resolution: Recieved class survey report from NKK dated 26 SEP 2007 stating new liferafts on board.
Operations/Management › Pollution › Control of Garbage
Issued 24 September 2007 Resolved
Vessel does not have a ship specific Garbage Management Plan. Vessel is to have a ship specific Garbage Management Plan prior to next U.S. port call after sailing foreign.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 October 2007
Resolution: Received updated Garbage Management Plan via fax.
Operations/Management › Pollution › Report of Discharge
Issued 24 September 2007 Resolved
Garbage record book has no entries for garbage or ash transfers ashore since December of 2006.
Action required: 705 - Other - as specified
Resolved 24 September 2007
Resolution: Crew was given instruction on proper record keeping requirements.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 September 2007 Resolved
Sewage treatment plant is not being maintained in accordance with the manufacturer's instructions. Pencil notations have been made in the manual to use gamazine instead of the required hypochlorite tablets. Vessel is to provide documentation attesting to proper maintenance of sewage treatment plan from manufacturer/class.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 2 November 2007
Resolution: Vessel submitted a report that certifies they are now using chlorine tablets and they had their class society sign off on it. [name withheld]
Navigation › Collision/Grounding Avoidance › Transponder
Issued 21 June 2005 Resolved
Vsl issued Letter of Deviation for inoperative AIS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2005
Resolution: Necessary repairs made, vsl cleared to sail.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 14 April 2002 Resolved
TEMPORARY BRACKET (TWISTED WIRE) INSTALLED ON LOW PRESSURE CO2 LIGUID LEVEL LINE FROM TNAK TOP PADEYE TO LIGUID LINE REGULATOR, INSTALLED TO STOP VIBRATION. MAKE PERM REPAIRS AND PROVIDE CLASS REPORT. LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 May 2002
Resolved 7 June 2002
Resolution: Cleared by fax from Agent of Class Report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.