07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2026
Resolved
Replace pull pin wire for fire boy. Failed annual inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 April 2026
Resolved
Add scupper on AFT exit of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2026
Resolved
Fix line on life ring light no longer than 6ft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2026
Resolved
Update drills and EPIRB logs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2026
Resolved
Replace 02 fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2025
Resolved
Ring buoy retro tape is faded and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2025
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2025
Resolved
04 life jackets need to have retro tape replaced its worn and faded.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2025
Resolved 5 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2025
Resolved
Life float paddles are required to contain the vessel's name on them. Label paddles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2025
Resolved 5 August 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 July 2025
Resolved
Vessel is required to have CREW ONLY / NO PASSENGERS marked on the topside ladders. Label ladders.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2025
Resolved 5 August 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 March 2024
Resolved
Raw water suction valve for MDE dose not operate freely. Clean valve so it will open and close easily.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2024
Resolved 22 March 2024
Resolution: Raw water suction valve was replaced with a new unit. Valve was inspected and tested for functionality.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 June 2023
Resolved
Vessel's COI has an anniversary date of 2/24 with expiration of 2/24/2027. Vessel is required to have an annual inspection conducted within 90 days before or 90 days after anniversary date. Last day of the 90 window was May 25th 2023 to have annual inspection completed. Vessel failed to have annual inspection completed within the 6 month window. Vessel must have inspection completed prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2022
Resolved
Vessel broke down and had to get towed in with passengers on board. Must conduct repairs and conduct satisfactory sea trials prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2022
Resolution: New transmission installed, MDE serviced, Conducted satisfactory sea trials
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2022
Resolved
Ruptured coolant hose on the MDE. Replace with new hose, and refill lost coolant.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2022
Resolved 30 March 2022
Resolution: Operator submitted video footage of newly installed coolant hose. Video contained footage of MDE temperature guage indicating normal operating temp. No leaks were observed in the video footage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2022
Resolved
2 of the 3 high water bilge alarms do not work. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2022
Resolution: 2 new high water alarms installed, tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2022
Resolved
Life ring retro tape is faded/worn and must be replaced
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 25 February 2022
Resolution: Replaced retro on life ring
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2022
Resolved
Vessel does not have a valid FCC Safety Certificate. Must have valid FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 7 June 2022
Resolution: New FCC Safety Certificate issued yesturday
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 March 2021
Resolved
Bilge system not working properly. Must have audio and visual indicators/alarms for each hight water alarm and a visual indicator for each automatic bilge pump when operating. Make repairs to all bilge pumps/alarms and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 25 February 2022
Resolution: Replaced the wiring and connections, test SAT
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 March 2021
Resolved
Rudder post mounting bracket and clamp are broken. Must make repairs and test to the satisfaction of atttending CG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 24 February 2022
Resolution: New mount was made and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 March 2021
Resolved
MDE is missing the front guard over the belts and pulleys. Must have guard to protect from rotating machinery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 February 2022
Resolution: Installed belt guard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 March 2021
Resolved
Vessel is missing the FCC safety certificate. Must have certified FCC inspector come out and re certify radio equipment.
47 CFR 13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 7 June 2022
Resolution: New FCC Safety Certificate issued yesturday.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 March 2021
Resolved
First aid kit has expired items. Must replace all expired/missing items to meet requirements in 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 10 May 2022
Resolution: New First aid kit meeting requirements onboard
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2021
Resolved
Life Float has D.O.T. retro tape instead of the SOLAS as required. Must replace all retro tape with SOLAS tape. Vessel is restricted to day light hours only until fixed and cleared by the CG.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 February 2022
Resolution: Replaced all with SOLAS reflective tape
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2021
Resolved
Life Float looked to have been spray painted with orange paint, which is an un approved repair. Must make approved repair in accordance with manufacture using international orange paint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 February 2022
Resolution: Life float was correctly repainted
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 March 2021
Resolved
Compass light is not working. Must make repairs to compass and test with CG Marine Inspector. Vessel is restricted to daylight hours only until fixed and cleared by CG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 February 2022
Resolution: fixed wiring connection, test SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2021
Resolved
Vessel does not have a crew training log and not properly logging fire drills and MOB drills. Need to make new log for crew training, and Fire and MOB drills.
46 CFR 185.420
46 CFR 185.520
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 25 February 2022
Resolution: Boat was sold, new company started new logs.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 1 March 2021
Resolved
essel had 3 expired flares onboard. Must have at least 6 red and 6 orange or 12 red flares. Must replace expired flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 1 March 2021
Resolution: Went to store and bought new flares
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 March 2021
Resolved
Life ring buoy light was found to have a broken clip used to secure light to buoy. Must replace quick release clip with CG approved clip. Vessel restricted to daylight hours only until fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 1 March 2021
Resolution: Went to store and bought new clip, re spliced and attached to ring buoy
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 March 2021
Resolved
Alcohol Swabs were missing, no proof of being able to test for Alcohol after a marine casualty. Plan is to one of the local dive shops meet at the dock if a marine casualty was to happen until they order new swabs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 February 2022
Resolution: New Alcohol swabs with experation date in 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2021
Resolved
2 Child and 1 adult life jacket was found with broken clips used to secure the life jacket to personl. Must replace all 3 life jackets. Passenger count reduced by 2 child and 1 adult until new ones onboard and labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 24 February 2022
Resolution: Inspected all life jackets. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2020
Resolved
Cutlass bearing worn down past 50%, replace cutlass bearing.
Action required: 705 - Other - as specified
Resolved 26 February 2020
Resolution: replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2020
Resolved
Remove or properly terminate dead end wires from previously removed bow thruster.
*Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 February 2020
Resolution: wires were properly terminated
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2020
Resolved
Replace flexible fuel line from port fuel tank to selector switch. Fuel lines must meet at minimum SAE 1527. Connections wasted and heavy scaling rust.
*Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 February 2020
Resolution: replaced flex fuel lines
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2020
Resolved
Replace aft flexible exhaust hose, wire reinforcement protruding out.
*Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 February 2020
Resolution: replaced aft exhaust hose
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 12 February 2020
Resolved
Cap off valve where unused cut hose goes into bilge off the Marine Sanitation Device.
*Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 February 2020
Resolution: capped of unused valve from MSD
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2020
Resolved
Replace chaffed high pressure fuel line identified by attending Marine Inspector, provide report from attending diesel engine mechanic attesting to proper location and installation of fuel rail clamps per manufacturer's requirements. Fixed fuel line clamps found loose and not supporting lines.
*Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 2 March 2020
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2018
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. Repair visual indicators for forward and middle bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2020
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2018
Resolved
A vessel must carry either a first aid kit approved under approval series 160.41 or a kit with equivalent contents and instructions. Provide a complete first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2020
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2018
Resolved
The floating water light for the life float must be attached by a lanyard that is 3/8" diameter, resistant to uv light, and at least 18 feet. Provide new lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2020
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2018
Resolved
VHF radio must have GPS input
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2020
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 February 2017
Resolved
Vessel COD is expired. Renew COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2017
Resolution: New COD was issued and verified.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 February 2017
Resolved
FWD compartment and engine room bilge high level alarm are inoperable. Renew/repair prior to any operations with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2017
Resolution: New bilge alarms were installed and tested, all sat.
Communications › Audible Communications › SPD (Other)
Issued 8 February 2017
Resolved
Vessel does not have a sound producing device onboard. Provide new SPD, or repair electric horn.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: New SPD was provided and tested, all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 February 2017
Resolved
Life float light lanyard is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: New lanyard was installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 February 2017
Resolved
All PFD have failing reflective tape, and must be repaired/replaced.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: New SOLAS approved reflective tape was installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 February 2017
Resolved
FCC safety telephony Certificate is expired, provide new cert.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: New FCC cert was provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 February 2017
Resolved
Drug testing information was not available at time of inspection, Provide proof of enrollment for all employees
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: Proof of consortium enrollemnt was provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 February 2017
Resolved
Vessel does not have a emergency broadcast placard. Provide and post near radio.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: New placard was posted.
Lifesaving › Lifefloat › Painter
Issued 8 February 2017
Resolved
Life float painter and reflective tape are wasted and must be replaced.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: Painter line was replaced, and new retro was installed.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 February 2016
Resolved
Re-new cutlass bearing.
Due 10 February 2016
Resolved 10 February 2016