ESCAPADE

ESCAPADE is a 2002 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2001, most recently in July 2025, along with 23 deficiencies, 1 operational control and 3 casualty investigations between 2002 and 2010.

Records from 2001 to 2025. Most recent: inspection, 14 July 2025.

Built
2002
Last inspected
14 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA8845
562287
Flag
UNITED STATES
366858650
Maury page id
psix-562287

Inspections, by type

…with no type recorded3
Years with a record 22 calendar years (2001–2025)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 12.3 ft × 5.5 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCANAVERAL CUSTOM BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 6 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA8845MMSI 366858650 · active · compulsorily equipped · granted 6 April 2022, expires 20 June 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 38

14 July 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8170790
5 November 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8029723
3 April 2024 Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7889622
8 November 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821771
21 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611931
29 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601613
19 April 2022 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7433523
12 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7330839
1 September 2020 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7046911
7 April 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6936169
10 December 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6872325
20 September 2019 Type not recorded
No type recorded · Station Monterey · USCG Southwest District (CGD-SW) · Activity 6817076
25 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600810
19 September 2018 Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6545659
10 April 2018 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6390439
22 February 2018 Examination of Repairs · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6360218
7 December 2017 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6323070
7 December 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6053511
22 February 2016 Plan Review "T" Boat · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5819963
2 November 2015 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5755860
16 July 2015 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5184559
12 June 2014 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4887069
1 May 2012 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4349048
1 December 2011 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4248172
5 July 2011 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4070468
16 June 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3235308
27 May 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3208404
27 June 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2973916
16 August 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2748010
23 May 2006 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2655919
10 June 2005 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2386268
28 June 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2113699
4 June 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2089039
2 September 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1888900
3 August 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1867490
30 November 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1712743
5 August 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1651964
29 April 2001 Construction Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1647824

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 July 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Observed exposed wires in forward hatch compartment. Remove or cap the exposed wires. (46 CFR 183.200)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 16 July 2025
Resolution: Uncapped wires were removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 July 2025 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces.. observed peeling foam barrier in the lazarette compartment leading to the engine room's Fire Boy. Affix new foam to cover the opening. (46 CFR 177.405(e))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 16 July 2025
Resolution: Bulkhead sealant was replaced around the Fireboy cable.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 July 2025 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or toher standard specified by the Commandant.. observed that retroreflective tape on the life ring buoy was faded and peeling. Replace tape on the life ring buoy. (46 CFR 180.70(b)(1))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 16 July 2025
Resolution: SOLAS tape was replaced on both sides of the throw ring.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fire servicing report attesting to engine room Pre-enginnered fireboy system was unavailable. Procure for review to MI satisfaction. 46 CFR 176.810(b)(1)(iv)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 November 2024
Resolution: Recieved SAT fire servicing report from operator.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 April 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI…may require…permanent repairs. Repair identified cracking on deck IVO port side engine hatch in forward starboard and port aft corners to the satisfaction of the marine inspector. 46CFR176.600(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2024
Resolved 18 April 2024
Resolution: Photographs of repair accepted as evidence of satisfactory corrective action. See attached document "7889622_DD Admin Insp_Def Check"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Replace worn starboard cutlass bearing for credit dry dock. 46CFR176.670(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2024
Resolved 18 April 2024
Resolution: MI accepted receipt for bearing repair as evidence of corrective actions. See attached document "7889622_DD Admin Insp_Def Check"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected. MIs found wet exhaust leaking IVO rubber flex connection between wet exhaust water injection ring and exhaust pipe on both propulsion engines. Operator to rectify deficiency to the satisfaction of OCMI. 46 CFR 176.830(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2022
Resolved 9 December 2022
Resolution: [name withheld] sent in video evidence which included close up video shots of engines running and no observed leak IVO deficiency.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 October 2021 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). Vessel needs to input MMSI number into VHF radio and link GPS to VHF to allow DSC feature to be operational. 47 CFR 80.905(a)(1).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 5 November 2021
Resolution: VHF/DSC has been successfully connected to display appropriate GPS data and MMSI number has been inputed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 October 2021 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. Vessel shall install appropriate rudder stops during next scheduled dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 19 April 2022
Resolution: Operator installed rudder stops.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 February 2019 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessel Fireboy does not shutdown port side engine when pin is pulled to test the shutdown functionality of the system. Operator must have technician service the system, troubleshoot, and correct the deficiency.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2019
Resolved 27 February 2019
Resolution: Vessel operator submitted 5 page tech report detailing testing and repair to malfunction of fireboy auto shutdown for portside engine. all tests satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 February 2019 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Stowed so that when the vessel sinks the survival craft floats free and, inflates automatically. Vessel IBA painter secured permanently to the vessel, bypassing the float-free link. Ensuring if the vessel sank it would cause IBA to sink as well. Vessel must secure IBA painter properly to float-free link.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 February 2019
Resolved 25 February 2019
Resolution: Vessel master submitted photos to MI showing re-arrangement of painter line properly connected to the float free link.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 February 2018 Resolved
1) Prove fuel and cooling water hose meet SAE J1942 and fuel fittings meet SAE J1475 following re-power of stbd engine.
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 23 March 2018
Resolution: Hoses meet SAE J1942.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 7 December 2017 Resolved
Pressure gauge on one B-11 extinguisher was in the red, even though the extinguisher has been serviced in Oct 17.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 December 2017
Resolved 8 December 2017
Resolution: Estinguisher was serviced by A&B Fire and placed back into service on the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2011 Resolved
Provide Iodine and Ammonia inhalants in first aid kit.
Due 20 July 2011
Resolved 18 July 2011
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2011 Resolved
Provide up to date charts and adequate charts for intended service.
Due 20 July 2011
Resolved 18 July 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 June 2008 Resolved
Repair disconnected / bare wires in forward chain locker.
Due 27 June 2008
Resolved 16 June 2008
Resolution: Corrected 5/28 after owner submitted pictures of repair via email.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 10 June 2005 Resolved
Provide an Oil Pollution Placard.
Due 19 July 2005
Resolved 19 July 2005
Documentation › Markings/Placards
Issued 5 August 2002 Resolved
Label emergency escape hatch on outside with "EMERGENCY EXIT, KEEP CLEAR".
Due 5 August 2002
Resolved 5 August 2002
Resolution: Exterior of hatch properly marked with the words "EMERGENCY EXIT, KEEP CLEAR".
Lifesaving › Hand Flares › Marking
Issued 5 August 2002 Resolved
Properly label location where distress flares are stored.
Due 5 August 2002
Resolved 5 August 2002
Resolution: Flare stowage area is properly labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 August 2002 Resolved
Replace all expired meds in first aid kit with unexpired meds.
Due 5 August 2002
Resolved 5 August 2002
Resolution: Expired medications have been replaced with unexpired medications.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 August 2002 Resolved
Properly label storage area for correct quantity of adult and child life preservers.
Due 5 August 2002
Resolved 5 August 2002
Resolution: Life jacket stowage areas are properly marked with quantities.
Lifesaving › Lifebuoys
Issued 5 August 2002 Resolved
Properly install corrosion resitant clip to float light lanyard on lifebuoy.
Due 5 August 2002
Resolved 5 August 2002
Resolution: Corrosion resitant clip has been attached to the float light lanyard on lifebuoy.
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 5 August 2002 Resolved
Update emergency instructions IAW 46 CFR 185.512
Due 5 August 2002
Resolved 5 August 2002
Resolution: Emergency instructions are updated to reflect 46 CFR 185.512.

Casualty record · 3

30 November 2002Routine · role: Subject to Marine Inspection · 1 dead · activity 1712743
3 August 2003Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1867490
18 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3719656
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.