MAURY USCG vessel records Sign in
← All vessels

ECO VANQUISH

ECO VANQUISH is a 2002 freight ship. The Coast Guard has recorded 23 inspections since 2002, most recently in September 2010, along with 6 deficiencies and 4 operational controls.

Records from 2002 to 2010. Most recent: inspection, 23 September 2010.

Built
2002
Last inspected
23 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9254745 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
562302
Flag
PANAMA
—
Maury page id
psix-562302

Inspections, by type

…with no type recorded5
Years with a record 9 calendar years (2002–2010)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it10748 - Convention (Subpart B), Net Ton
17953 - Convention (Subpart B), Gross Ton
29887 - Dead Weight, Ton
35880 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

23 September 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3855671
8 February 2010 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3676782
28 January 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3401752
29 December 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3386126
23 August 2008 ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3302442
12 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3163294
9 March 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3160957
17 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2933037
12 May 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2928472
30 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2916796
15 August 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2748673
9 August 2006 Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2740035
13 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2602909
12 November 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2533184
1 July 2005 ISPS III Exam · PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2410012
26 January 2005 PII Safety Exam · Spot Check · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2279912
15 September 2004 ISPS III Exam · NPV Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2196699
15 August 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2166570
21 May 2004 Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2076930
6 June 2003 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1806983
16 April 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1780469
16 February 2003 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1745339
29 April 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1604141

Deficiency record · 6

Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 February 2010 Resolved
Lifebuoys must be properly marked with retro reflective material. Several life buoys onboard were marked with failed retro reflective material.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2010
Resolved 19 February 2010
Resolution: Vessel replaced retro reflective material on life buoys.
Lifesaving › Lifeboat › Fender
Issued 8 February 2010 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Lifeboat on STBD side has wasted fender affecting its launching and embarking capabilities. SOLAS 74, 04 Consolidated CH 3 20.2
Action required: 705 - Other - as specified
Due 10 March 2010
Resolved 18 February 2010
Resolution: Fender for port side of STBD life boat replaced with new one.
Fire Fighting › Ventilation Systems › Ducts
Issued 8 February 2010 Resolved
Means of control shall be provided by the opening and closure of ventilation in machinery spaces. The fire damper for the emergency generator ventilation has been removed. Provide class report that this is an approved modification by the administration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2010
Resolved 18 February 2010
Resolution: Door was fabricated satisfactory to provide weather tight sealing for emergency generator ventilation.
Engineering › Steam System (auxiliary) › Piping
Issued 8 February 2010 Resolved
Steam piping system and fittings in addition to insulating material presents a danger to persons on board due to hot surfaces. Fittings in the steam heating systems are leaking and damaging insulating material. The heavy fuel oil and steam piping deteriorating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2010
Resolved 18 February 2010
Resolution: Piping replaced and fitted with adequate insulation.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 August 2006 Resolved
The saltwater outlet pipe for the Main Engine L/O cooling has a temporary soft patch. Repair pipe to the satisfaction of the attending classification society.
Action required: 705 - Other - as specified
Due 23 August 2006
Resolved 15 August 2006
Resolution: Vessel provided class report showing repairs had been made to outlet pipe.
Fire Fighting › Remote Fuel Shutoff
Issued 6 June 2003 Resolved
Fix to the satisfaction of the class society the air reservoir for the emergency shut off valves for the F.O. and L.O. tanks. There is an air leak by the pressure relief valve for this tank. SOLAS 74 amd I/11.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2003
Resolution: Received non-conformity report and report of corrective action from vessel designated person ashore. Satisfactory repairs were conducted.

Ownership record