MAURY USCG vessel records Sign in
← All vessels

ULTRAMAR I

ULTRAMAR I is a 1995 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2002, most recently in May 2007, along with 87 deficiencies — 1 with no resolution recorded — and 6 operational controls.

Records from 2002 to 2007. Most recent: inspection, 5 May 2007.

Built
1995
Last inspected
5 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9015553 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
562922
Flag
MEXICO
—
Maury page id
psix-562922

Inspections, by type

…with no type recorded6
Years with a record 4 calendar years (2002–2007)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it216 - Convention (Subpart B), Net Ton
659 - Convention (Subpart B), Gross Ton
135 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

5 May 2007 PII Safety Exam · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2903876
7 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2868566
8 September 2006 Deficiency Check · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2771805
5 September 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2770262
5 June 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1810561
2 June 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1807502
26 March 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1763140
24 March 2003 Quarterly Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1753885
3 January 2003 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1725368
28 December 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1724135
24 December 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1722706
17 December 2002 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1719876
17 December 2002 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1720051
16 December 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1719316
14 December 2002 Quarterly Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1718915
11 December 2002 Quarterly Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1717865
8 December 2002 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1715922
8 December 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1715923
29 November 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1712243
15 November 2002 Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1706108
14 November 2002 Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1705254
30 August 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1679722
21 June 2002 Passenger/Freight Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1635371
22 May 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1619784
22 May 2002 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1619789

Deficiency record · 87

Lifesaving › Inflatable Liferafts › Servicing
Issued 9 April 2007 Resolved
While inspecting the lifesaving equipment the PSCO noted that all 26 Rigid life rafts were heavily worn and in varying states of serious disrepair caused by excessive exposure to sun and weather. The vessel is to replace all life rafts to the satisfaction of the certificate issuing authority within seven days.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 28 November 2012
Resolution: Vessel examined with satisfactory life float while at Midstream Marine Shipyard.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 9 April 2007 No resolution recorded
Upon the documentation portion of the inspection the PSCO noted that the vessel does not have Oil Transfer Procedures on board. Vessel is prohibited to conduct bunkering operations in U.S. waters until an approved Oil Transfer Procedures is on board the vessel.
Action required: 705 - Other - as specified
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 8 September 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2006
Resolved 9 November 2006
Resolution: Received proper documentation from the master of the vessel satisfying requirement.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 8 September 2006 Resolved
Batteries have expired for both SARTs on bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2006
Resolved 9 November 2006
Resolution: Received proper documentation from the master of the vessel satisfying requirement.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 June 2003 Resolved
Provide the crew list with mariners credentials for the anchor watch. (Vessel shifted from the C'sted pier to anchorage on or about 31 May 2003) See MSO San Juan COTP 1790017 for details.
Due 3 June 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the ships records and found to be in order.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 June 2003 Resolved
Provide updated hurricane plan to include individuals listed by name with copies of their mariner credentials.
Due 3 June 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class ships records and found to be in order.
Construction/Loadline › Hull › Side Shell
Issued 28 December 2002 Resolved
Make proper repairs to fractured weld joining the transom and side shell approximately 18 inches above the waterline.
Due 28 January 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Construction/Loadline
Issued 28 December 2002 Resolved
Provide documentary evidence of class acceptance of the 2 mm gouges in the hull.
Due 28 January 2003
Resolved 29 December 2002
Construction/Loadline › Hull › Side Shell
Issued 28 December 2002 Resolved
Update Safety Management system records to reflect 24 Dec 2002 allision.
Due 28 January 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed ships records and found to be in order.
Fire Fighting
Issued 28 December 2002 Resolved
Make proper repairs to the fire detection system.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2003
Resolved 28 December 2002
Construction/Loadline
Issued 24 December 2002 Resolved
Make repairs the holed hull and proximate welds.
Action required: 705 - Other - as specified
Resolved 29 December 2002
Construction/Loadline
Issued 24 December 2002 Resolved
Make proper repairs to the deep gouges in the hull.
Action required: 705 - Other - as specified
Resolved 29 December 2002
Navigation › Piloting/Steering › Marine Charts
Issued 14 December 2002 Resolved
Provide current corrected navigation charts.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the navigation charts and found to be in order.
Navigation
Issued 14 December 2002 Resolved
Make proper repairs to door between main deck bar and storage area.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2003
Resolved 14 December 2002
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 11 December 2002 Resolved
Make proper repairs to the satisfaction of the classification society representative to the starboard main engine.
Due 11 January 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 29 November 2002 Resolved
Make proper repairs to the ARPA. Repairs to be made to the satisfaction of the classification society representative. Provide qualified technicians report to Resident Inspection Office St. Croix. (Requirement duplicated by COTP 1712185)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2002
Resolved 8 September 2006
Resolution: No ARPA on board.
Fire Fighting › Fire Patrol › Call Points
Issued 29 November 2002 Resolved
Make repairs to the fire detection system. Repairs to be made to the satisfaction of the classification society representative and technicians service report provided to Resident Inspection Office St. Croix. (Duplicates COTP)
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 November 2002 Resolved
Make repairs to the vessels radars. Repairs to be made to the satisfaction of the classification society representative and technicians report to be provided to Resident Inspection Office St. Croix. (Duplicated by COTP)
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Pollution Prevention/Response
Issued 29 November 2002 Resolved
Provide invoice for bilge pumping.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Engineering
Issued 29 November 2002 Resolved
Renew starboard generator oil pressure gage.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Fire Fighting
Issued 29 November 2002 Resolved
Provide evidence of service of Halon System.
Action required: 705 - Other - as specified
Due 29 December 2002
Resolved 8 December 2002
Resolution: corrected
Pollution Prevention/Response
Issued 29 November 2002 Resolved
Remove oily/water mixture from Port MDS actuator space.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Pollution Prevention/Response
Issued 29 November 2002 Resolved
Remove oily/water mixture from starboard MDS actuator space.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Construction/Loadline › Structures › End Bulkhead
Issued 29 November 2002 Resolved
Make repairs to the hole in the collision bulkhead, portside.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Lifesaving
Issued 29 November 2002 Resolved
Properly secure PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Fire Fighting
Issued 29 November 2002 Resolved
Renew aft upper deck fire suit SCBA bottle. Corrected on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 29 November 2002
Resolution: Corrected on the spot.
Navigation
Issued 29 November 2002 Resolved
Prove operation of the day light signaling lamp. (Corrected on the spot)
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2002
Resolved 29 November 2002
Navigation
Issued 29 November 2002 Resolved
Make repairs and prove operation of the spotlight prior to operating at night.
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Engineering
Issued 29 November 2002 Resolved
Make repairs to the leak on the port main diesel engine, inboard.
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 8 December 2002
Resolution: corrected
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 29 November 2002 Resolved
Provide evidence of satisfactory issuing classification society review of vessel safety management system.
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Construction/Loadline › Hull › Side Shell
Issued 29 November 2002 Resolved
Complete permanent repairs to shell damage in void space 2 st BD at MDS to the satisfaction of Coast Guard Marine Inspector and classification society representative.
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 November 2002 Resolved
Submit for classification society approval, repair proposal for fractures in the forward space in the vicinity of the anchor winch support.
Due 19 November 2002
Resolved 8 September 2006
Resolution: The Marine Inspector reviewed the Class survey and found to be in order.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 November 2002 Resolved
Complete repairs in accordance with the class approved plan.
Due 22 November 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 November 2002 Resolved
Monitor the internal structural condition of the vessel. Exams to be completed after the first morning round trip and in St. Thomas prior to returning to St. Croix on the last trip of the day.
Due 15 January 2003
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Engineering
Issued 15 November 2002 Resolved
Make repairs to starboard generator oil pressure gage. Repairs to be made to the satisfaction of class.
Due 22 November 2002
Resolved 8 December 2002
Resolution: corrected
Pollution Prevention/Response
Issued 15 November 2002 Resolved
Investigate, determine source of sewage odor in the steering spaces. Repairs to be to the satisfaction of classification society representative.
Due 22 November 2002
Resolved 15 November 2002
Engineering
Issued 15 November 2002 Resolved
Make repairs to the satisfaction of classification society representative to the lube oil leak in the port side Main Engine.
Due 22 November 2002
Resolved 8 December 2002
Resolution: corrected
Construction/Loadline
Issued 14 November 2002 Resolved
Provide evidence of class acceptance of temporary repair to hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2002
Construction/Loadline
Issued 14 November 2002 Resolved
Make permanent repairs to hull as detailed in DNV ltr dated 13 Nov 2002, ref:NYK-1280-02 prior to carrying passengers for hire after 18 November 2002 drydock.
Due 19 November 2002
Resolved 8 December 2002
Resolution: corrected
Construction/Loadline › Hull › Side Shell
Issued 14 November 2002 Resolved
Submit CG-2692 for casualty detailed in DNV letter dated 2002-11-13 ref: NYK-1280-02
Due 14 November 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed ships records and found to be in order.
Construction/Loadline
Issued 31 August 2002 Resolved
Renew fasteners in the lifting hole covers.
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 31 August 2002
Electrical
Issued 29 August 2002 Resolved
Make port main eng acc start battery vapor tight.
Due 29 September 2002
Resolved 31 August 2002
Personnel
Issued 29 August 2002 Resolved
Provide crews work/rest cycle to the satisfaction of class. Classification society representative to document work/rest cycle is adequate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2002
Resolved 31 August 2002
Fire Fighting
Issued 29 August 2002 Resolved
Properly label engine room exterior fire dampers.
Due 29 September 2002
Resolved 31 August 2002
Fire Fighting
Issued 29 August 2002 Resolved
test
Due 29 September 2002
Resolved 29 August 2002
Pollution Prevention/Response
Issued 29 August 2002 Resolved
Provide evidence of COFR.
Due 29 August 2002
Resolved 29 August 2002
Electrical
Issued 29 August 2002 Resolved
Provide documentary evidence of Administration approval of failure mode and effect analysis iaw DSC 9.1.7.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2002
Resolved 31 August 2002
Engineering
Issued 29 August 2002 Resolved
Provide classification society representative documentation of satisfactory test of the auxiliary generators
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Personnel
Issued 28 August 2002 Resolved
Man the vessel iaw the manning certificate providing evidence of administration acceptance of crews license.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2002
Resolved 8 December 2002
Resolution: corrected
Documentation
Issued 28 August 2002 Resolved
Provide documentation of class approval of technical manual
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Documentation
Issued 28 August 2002 Resolved
Provide documentary evidence of class and flag acceptance or exemption of base port iaw DSC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Construction/Loadline
Issued 28 August 2002 Resolved
Update buoyancy compartment checks in operating manual. Document class acceptance of the operating manual.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Fire Fighting
Issued 28 August 2002 Resolved
Update operating manual for fire prevention iaw DSC and provide documentary evidence of class acceptance of the update.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Lifesaving
Issued 28 August 2002 Resolved
Provide updated and approved evacuation plan to include emergency exits, emergency shutoffs, locations of the fire control plan, and international shore connection. Evacuation plan to be approved by classification or administration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Engineering
Issued 28 August 2002 Resolved
Update the maintenance manual iaw DSC 1.8.1 and provide documentary evidence of classification society rep approval of the update.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Lifesaving
Issued 28 August 2002 Resolved
Properly label emergency door method of operation (handle direction to open and close.)
Due 28 September 2002
Resolved 28 August 2002
Navigation
Issued 28 August 2002 Resolved
Provide towing bridle. Classification society rep to document approval of the towing bridle arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Communications
Issued 28 August 2002 Resolved
Remove expired line throwing cartridges.
Due 28 September 2002
Resolved 29 August 2002
Communications
Issued 28 August 2002 Resolved
Provide instructions for the line-throwing gun.
Due 28 September 2002
Resolved 31 August 2002
Documentation
Issued 28 August 2002 Resolved
Renew vessel name on the stern.
Due 28 September 2002
Resolved 31 August 2002
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 August 2002 Resolved
Provide documentary evidence from classification society rep that the electrical cables are properly terminated in junction boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 August 2002 Resolved
Properly support electrical cables. Satisfactory support to be documented by classification society rep.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.
Electrical
Issued 28 August 2002 Resolved
Make battery boxes vapor tight as required by DSC.
Due 28 September 2002
Resolved 31 August 2002
Engineering
Issued 28 August 2002 Resolved
Properly mark emergency fuel shutoffs remotes. Classification society rep to document that the markings are satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 31 August 2002
Fire Fighting
Issued 28 August 2002 Resolved
Provide international shore connection.
Due 28 September 2002
Resolved 8 December 2002
Resolution: corrected
Lifesaving
Issued 28 August 2002 Resolved
Properly label location of storage of child PFD's and provide classification society documentation that the stowage and markings of the PFD stowage are satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2002
Resolved 8 December 2002
Resolution: corrected
Engineering
Issued 28 August 2002 Resolved
Make proper repairs to the starboard generator gages.
Due 28 September 2002
Resolved 8 December 2002
Resolution: corrected
Pollution Prevention/Response
Issued 28 August 2002 Resolved
Remove oily water mixture from the bilge and properly clean the bilges. Cleaning to be to the satisfaction of and documented by the classification society representative.
Action required: 705 - Other - as specified
Due 28 September 2002
Resolved 8 December 2002
Resolution: corrected
Construction/Loadline
Issued 23 August 2002 Resolved
Make permanent repairs to the hull cracks in the forepeak. Repairs to be documented by the classification society representative.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2002
Resolved 31 August 2002
Engineering
Issued 23 August 2002 Resolved
Make permanent repairs to the starboard forward bilge pumps. Repairs to be documented by the classification society rep.
Due 23 September 2002
Resolved 31 August 2002
Engineering
Issued 23 August 2002 Resolved
Complete satisfactory test of all bilge pumps. Test to be documented satisfactory by the classification society representative.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2002
Resolved 31 August 2002
Engineering
Issued 23 August 2002 Resolved
Make permanent repairs to the motion dampening system. Repairs to be documented by the classification society rep.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2002
Resolved 31 August 2002
Engineering
Issued 23 August 2002 Resolved
Make repairs to the port generator gages. Repairs to be documented by classification society rep.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2002
Resolved 8 December 2002
Resolution: corrected
Engineering
Issued 23 August 2002 Resolved
Make repairs to the port generator jacket water cooler leaks.
Due 23 September 2002
Resolved 28 August 2002
Engineering
Issued 23 August 2002 Resolved
Make repairs to the port generator fractured shut down panel.
Due 23 September 2002
Resolved 31 August 2002
Engineering
Issued 23 August 2002 Resolved
Make repairs to the port main engine lube oil leaks
Due 23 September 2002
Resolved 29 August 2002
Engineering
Issued 23 August 2002 Resolved
Properly label emergency exits.
Due 23 September 2002
Resolved 23 August 2002
Fire Fighting
Issued 21 June 2002 Resolved
Service fixed fire-fighting systems to include ventilation and machinery shutdowns. Service to be completed and documented to the satisfaction of the classification society and the attending CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2002
Resolved 31 August 2002
Engineering
Issued 21 June 2002 Resolved
Make proper repairs and prove operation of the load management system to include the synchro switch. Repairs to be made to the satisfaction of classification society and attending CG Inspector. Classification society rep to document the repairs are satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2002
Resolved 31 August 2002
Engineering
Issued 21 June 2002 Resolved
Provide generator coolers suitable for tropical waters.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2002
Resolved 23 August 2002
Engineering
Issued 21 June 2002 Resolved
Renew as original to the satisfaction of the classification society the water regulating valve in the vicinity of the air conditioning compressors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2002
Resolved 23 August 2002
Communications
Issued 21 June 2002 Resolved
Make repairs and prove operations of the talk back system. Repairs to be completed to the satisfaction of the classification society and the attending CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2002
Resolved 28 August 2002
Navigation
Issued 21 June 2002 Resolved
Install navigation lights iaw COLREGS. Installation to be to the satisfaction of the classifaction society.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2002
Resolved 23 August 2002
Construction/Loadline
Issued 21 June 2002 Resolved
Submit for approval hull-monitoring program.
Due 23 September 2002
Resolved 28 August 2002
Fire Fighting
Issued 21 June 2002 Resolved
Update the fire control plan to include the upper bar portable extinguisher. Update to be documented by classification society rep.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2002
Resolved 31 August 2002
Engineering
Issued 21 June 2002 Resolved
Provide documentary evidence of classification society representative satisfactory test of the equipment described in the power management manual.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2002
Resolved 31 August 2002
Electrical › Lighting (emergency) › Conductor
Issued 21 June 2002 Resolved
Demonstrate to the satisfaction of the classification society representative the operation of the machinery space emergency lighting. Provide documentary evidence from the class society of the satisfactory performance of the below deck emergency lighting.
Due 29 August 2002
Resolved 8 September 2006
Resolution: Marine Inspector reviewed the Class survey and found to be in order.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.