EXPLORIS ONE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2002, most recently in July 2019, along with 53 deficiencies and 1 operational control.

Records from 2002 to 2019. Most recent: inspection, 10 July 2019.

Built
1989
Last inspected
10 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8806747 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
563093
Flag
BAHAMAS, THE
—
Maury page id
psix-563093

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2002–2019)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it750 - Dead Weight, Ton
1905 - Displacement, Ton
6130 - Convention (Subpart B), Gross Ton
6072 - Regulatory (Subpart C or D), Gross Ton
1839 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

10 July 2019 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6751013
21 June 2019 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6724426
29 April 2019 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6668928
29 April 2019 COE-Dockside
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6672242
7 August 2018 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6504142
4 June 2018 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6434315
2 May 2018 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · Deficiency Check · MARPOL Annex VI Survey · COC-CVE Quarterly
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6397804
24 September 2017 MARPOL Annex V Examination · ISPS II Exam · COC-CVE Annual · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6264986
4 October 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6015481
26 September 2016 COC-CVE Initial · COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6009965
12 September 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3323114
6 September 2008 COC-CVE Initial
Administrative · Activities Europe · Activity 3318847
25 August 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3308472
19 August 2008 ILO-147 Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · COC-CVE Annual · Administrative Inspection · MARPOL Annex V Examination · STCW 95 Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3302787
20 May 2004 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2090523
16 September 2003 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1905869
23 May 2003 Certificate of Compliance · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1798673
22 May 2003 Type not recorded
No type recorded · USCGC SASSAFRAS (WLB 401) · USCG Oceania District (CGD-O) · Activity 1802358
19 September 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1675922
19 June 2002 Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1633457
17 June 2002 MARPOL Annex V Examination · MARPOL Annex I Examination · Deficiency Check · Security Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1635668
29 May 2002 Control Verification · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1620696
18 April 2002 MARPOL Annex V Examination · Control Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1606061

Deficiency record · 53

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2019 Resolved
07105 Fire Doors in main vertical zone bulkheads and stairway enclosures shall be self closing and capable of closing at an angle of inclination of up to 35 degrees opposing closure and a rate of closure of no more than 40 seconds and no less than 10 seconds with the ship in the upright position. FSD 3079 and 3072 did not close properly. SOLAS (81 Amendments) CH. II-2, Reg. 30.4
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Ship personnel proved proper operation of Fire Doors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2019 Resolved
07199 In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of th oil fuel shall be such as to ensure the safety of the ship and persons on board. Hoses on the Zodiac oil fill tanks were found degraded increasing the likelihood of leakage and ignition. SOLAS (1997) CH. II-2, Reg. 15.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 29 April 2019
Resolution: Ship personnel removed degraded hoses from tanks and placed tanks in original approved condition.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 29 April 2019 Resolved
15106 The company and the ship shall comply with the requirements of the ISM Code, in regards to the functional requirements set forth in the safety management system. Ship personnel are not storing gas cylinders as per the vessel's SMS. SOLAS (2014) CH. IX, Reg. 3.1
Action required: 10 - Deficiency Rectified
Due 10 July 2019
Resolved 10 July 2019
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 2 May 2018 Resolved
Did not have annual hydrostatic test records of transfer pipes.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 2 May 2018
Resolution: [name withheld] carried out tests during course of examination.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 2 May 2018 Resolved
Modification to structural fire protection shall not be made without prior plan approval from the U.S. Coast Guard Marine Safety Center. A modification was discovered to the structural fire protection in several berthing areas without any documentation attesting to prior approval from the U.S. Coast Guard Marine Safety Center.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 30 August 2018
Resolution: Received correspondance from MSC that the "structural fire protection plan" and "Fire Control Plan" submitted by SILVER EXPLORER are REVIEWED.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 September 2016 Resolved
Cite: SOLAS 74 (1997 EDITION) II-2 REG 30.4.5 Action Taken: 50a (See form B)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2016
Resolved 24 September 2017
Resolution: All double leaf fire screen doors are equipped with automically activated latches.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 August 2008 Resolved
Conduct inflatable liferaft drill to the satisfaction of attending Coast Guard Marine Inspector. SOLAS 74 (2004ed) III/18.3
Action required: 705 - Other - as specified
Resolved 25 August 2008
Resolution: Conducted a satisfactory inflatable liferaft drill.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 August 2008 Resolved
Provide Coast Guard approved Nontank Vessel Response Plan prior to next US port after sailing Foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2008
Resolution: Sector Boston received the notarized interim letter for the NTVRP and scanned it into the documents section.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 May 2004 Resolved
Adjust fire safety doors to close flush against framing (doors 4053, 3081, 3079). LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 May 2004 Resolved
Install access panels throughout exhaust ducting in galley to allow for proper cleaning and inspection.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 May 2004 Resolved
Clean exhaust ducting throughout galley. Remove all oil and grease residue.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 May 2004 Resolved
Label circuit breakers for hot galley control area.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 May 2004 Resolved
Provide blanks for empty circuit breakers in galley.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 20 May 2004 Resolved
Provide documentation from class society reviewing/approving lack of escape diagrams in crew passenger accomodations.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 20 May 2004 Resolved
Replace food (provisions) on lifeboats as required. Replace all provisions that the vacuum seal has broken.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 20 May 2004 Resolved
Seal stuffing tube located port side on bridge in area of radio room.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 20 May 2004 Resolved
Repair/replace air conditioning handling unit in engine control room.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 20 May 2004 Resolved
Repair fuel oil leak on filter housing on #1 SSDE.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 May 2004 Resolved
Repair the installed battery charger in Emergency Diesel Generator room.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 August 2008
Resolution: Deficiency corrected during annual CVE inspection.
Pollution Prevention/Response › Prevention Equipment
Issued 23 May 2003 Resolved
MSD missing approval placard. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 15 - Rectify deficiencies by next port
Resolved 13 September 2003
Resolution: Inspected Type II Marine Sanitation Device. All found satisfactory and in compliance with the requirements of 33 CFR 159.16 and 33 CFR 159.
Documentation › Logs/Records
Issued 23 May 2003 Resolved
Pre-arrival tests not recorded in Bridge Log. LEGACY COMPONENT DESC: Logbook (official)
Action required: 15 - Rectify deficiencies by next port
Resolved 13 September 2003
Documentation › Manuals/Policy Documentation
Issued 23 May 2003 Resolved
Vessel name missing from manuvering fact sheet on the bridge. LEGACY COMPONENT DESC: Maneuvering Information
Action required: 15 - Rectify deficiencies by next port
Resolved 13 September 2003
Resolution: Provided vessel name on manuvering fact sheet.
Fire Fighting › Ventilation Systems
Issued 23 May 2003 Resolved
Laundry room vents have excessive amount of lint. LEGACY COMPONENT DESC: Ducts
Action required: 15 - Rectify deficiencies by next port
Resolved 24 September 2017
Resolution: Cleaned excessive lint from laundry room vents and vents are all operable.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 May 2003 Resolved
Fire screen door #6003 fails to automatically close completely.
Action required: 705 - Other - as specified
Resolved 23 May 2003
Resolution: Corrected prior to vessel''s departure.
Lifesaving › Lifeboat Equipment
Issued 23 May 2003 Resolved
Lifeboat provisions expire May 2003. LEGACY COMPONENT DESC: Food Ration
Due 1 June 2003
Resolved 13 September 2003
Resolution: Replaced expired lifeboat provisions.
Operations/Management › Mandatory Ship Reporting Systems
Issued 20 June 2002 Resolved
96 HR. ADVANCED NOTICE OF ARRIVAL WAS NOT SUBMITTED BY OWNER, AGENT OR CHARTERER PRIOR TO VESSEL ARRIVAL IN ST. PAUL, ALASKA ON 18 JUNE 02 AND NOME, ALASKA ON 20 JUNE 02. LEGACY COMPONENT DESC: Entry Report
Action required: 705 - Other - as specified
Due 20 June 2002
Resolved 20 June 2002
Resolution: AGENT SUBMITTED LATE COPY ON 19JUN02 TO NVMC FOR SUBSEQUENT US PORTS UNTIL NEXT FOREIGN VOYAGE.
Fire Fighting › Fixed Fire Detection System
Issued 17 June 2002 Resolved
BROKEN FIRE CALL POINT # 1513. TEMP REPAIRS ACCEPTED UNTIL PERMANENT PART REPLACED. LEGACY COMPONENT DESC: Manually Operated Call Points
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 19 September 2002
Resolution: USCG MARINE INSPECTOR INSPECTED FIRE CALL POINT #1513 AND FOUND IT BE OPERABLE.
Operations/Management › Navigation Safety
Issued 29 May 2002 Resolved
No Inland Navigation Rules on board LEGACY COMPONENT DESC: Carriage of Charts and Publications
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: SIGHTED COPY OF INLAND NAV RULES. NOT REQUIRED FOR OPERATING IN ALASKA WATERS IAW 33 CFR 80.1705
Personnel › Manning/Qualifications
Issued 29 May 2002 Resolved
No PIC designation. LEGACY COMPONENT DESC: Person in Charge (PIC) of Transfer
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: SIGHTED GENERIC PIC LETTER FOR C/E
Accommodation/Occupational Safety › Ventilation
Issued 29 May 2002 Resolved
The sewage space was not properly ventilated. LEGACY COMPONENT DESC: Sewage space
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: EXHAUST FAN WORKING PROPERLY
Engineering › Compressed Air System (control)
Issued 29 May 2002 Resolved
The compressors on top of the sewage tank leak oil. LEGACY COMPONENT DESC: Compressor
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: ALL LEAKS REPAIRED
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 29 May 2002 Resolved
Freon bottles in engineering spaces not secured. LEGACY COMPONENT DESC: freon bottles
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: FREON RELOCATED AND SECURED W/ METAL STRAP
Accommodation/Occupational Safety › Occupational Safety
Issued 29 May 2002 Resolved
Storage cabinet by sewage tank not properly secured.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: CABINET RELOCATED AND SECURED
Accommodation/Occupational Safety › Occupational Safety
Issued 29 May 2002 Resolved
Remove all flammable liquids from lifeboat and rescue boat deck. (gasoline and oil drums)
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: ALL FLAMMABLES REMOVED FROM VESSEL
Fire Fighting › Structural - A Class Divisions
Issued 29 May 2002 Resolved
Fire screen doors No. 5030 and 2096 do not latch closed. LEGACY COMPONENT DESC: Openings - Doors
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: TEST SAT
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 29 May 2002 Resolved
Forward escape from laundry blocked and or obstructed. LEGACY COMPONENT DESC: Laundry
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: ALL ROUTES CLEAR OF OBSTRUCTIONS
Documentation › Safety/Response Plans/Programs
Issued 29 May 2002 Resolved
Provide class approved fire control plan. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: FCP APPROVED BY NKK
Lifesaving › Immersion Suits
Issued 29 May 2002 Resolved
Provide SOLAS Certs. for all immersion suits ,install lights, retro reflective tape, and add vsl name.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: ALL SAT
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 29 May 2002 Resolved
Clear laundry room of all un-needed gear. Remove laundry from escape routes in laundry room. LEGACY COMPONENT DESC: Laundry
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: ALL CLEAR AT TIME OF INSPECTION
Accommodation/Occupational Safety › Cooking Systems
Issued 29 May 2002 Resolved
Prove proper operation of dampers in galley.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: WITNESSED PROPER OPERATION
Accommodation/Occupational Safety › Occupational Safety
Issued 29 May 2002 Resolved
Install low-level lighting (identification) placards for emergency equipment and exit signs at same level as photo-luminescense strips.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 23 May 2003
Resolution: Low level ID placards and exit signs installed.
Fire Fighting › Automatic Sprinkler System
Issued 29 May 2002 Resolved
Install proper insulation in overhead in way of sprinkler control station, adjacent to engine control room
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: INSULATED AS REQUIRED
Lifesaving › Lifebuoys
Issued 29 May 2002 Resolved
Lifering buoys need rescue lines to be spliced or whipped to girth of buoy.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: SAT
Electrical › Lighting (service)
Issued 29 May 2002 Resolved
Embarkation lights should all be operable.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 September 2017
Resolution: Eembarkation lights are all operable.
Electrical › Lighting (emergency)
Issued 29 May 2002 Resolved
Properly mark all emergency lights.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: MARKED AS REQUIRED
Fire Fighting › Structural - A Class Divisions
Issued 29 May 2002 Resolved
Prove proper operation of FSD for discover lounge. Closes out of sequence. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 19 September 2002
Resolution: VESSEL WILL POST PLACARDS AT SITE OF FSD FOR WORLD DISCOVER LOUNGE STATING BOTH BUTTONS WILL BE PRESSED MANUALLY TO RELEASE DOORS. IN ADDITION, VESSEL HAS DESIGNATED ONE CREW MEMBER TO SHUT FSD OF DISCOVER LOUNGE, NOTED IN FIRE DRILL PLAN.
Electrical › Lighting (emergency)
Issued 29 May 2002 Resolved
Place additional emergency lighting in alleyway outside boutique.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: LIGHT ADDED FOR EACH END OF ALLEYWAY
Fire Fighting › Structural - A Class Divisions
Issued 29 May 2002 Resolved
Fire screen door No. 3057 does not latch. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: TEST SAT
Fire Fighting › Structural - A Class Divisions
Issued 29 May 2002 Resolved
Fire doors 164 corridor, 205 AFT STBD galley need adjusting. LEGACY COMPONENT DESC: Openings - Doors
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: TEST SAT
Communications › Internal Communications System
Issued 29 May 2002 Resolved
Public address system does not work in UPS mode.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 19 September 2002
Resolution: PUBLIC ADDRESS SYSTEM IN GOOD OPERATING CONDITION WHEN IN UPS MODE. HAD VESSEL''S MASTER TEST PUBLIC ADDRESS SYSTEM UNDER VESSEL POWER AND IN BACK UP POWER. BOTH WERE SATISFACTORY.
Fire Fighting › Fixed Fire Detection System
Issued 29 May 2002 Resolved
Prove operation of smoke detectors #0705 and #0704 in UPS mode. LEGACY COMPONENT DESC: Smoke Detectors
Action required: 15 - Rectify deficiencies by next port
Resolved 17 September 2002
Resolution: TEST SAT
Fire Fighting › Fixed Fire Detection System
Issued 29 May 2002 Resolved
Prove operation of push button alarms (fire alarms) in UPS mode. LEGACY COMPONENT DESC: Manually Operated Call Points
Action required: 15 - Rectify deficiencies by next port
Resolved 17 September 2002
Resolution: TEST SAT
Electrical › Electric Generation Source (emergency)
Issued 29 May 2002 Resolved
UPS failed after 30 minutes.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: TESTED UPS. BATTERIES RENEWED, VOLTAGE DROP AFTER 30 MINUTES WITHIN ALLOWABLE 12% STANDARD.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.