← All vessels
WEST STAR
WEST STAR is a 2002 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in April 2026, along with 26 deficiencies.
Records from 2016 to 2026. Most recent: inspection, 1 April 2026.
- Built
- 2002
- Last inspected
- 1 April 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1126648
WDK5171
563998
Flag
UNITED STATES
Maury page id
psix-563998
Inspections, by type
Years with a record
11 calendar years (2016–2026)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 18.0 ft × 5.4 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)70.0 ft × 18.0 ft × 5.4 ft
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES INC · LA CROSSE, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
1 April 2026
COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8316725
20 February 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8082256
17 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8065154
26 April 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7905684
10 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7665565
25 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7506165
10 May 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7183822
29 January 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6892942
30 October 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6845928
23 September 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6818734
10 October 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6545670
29 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552806
2 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6265769
26 September 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6010152
26 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5894509
30 March 2016
Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844042
Deficiency record · 26
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2026
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: “Discharge of Oil Prohibited. The Federal Water Pollution Control Act prohibits the discharge of oil or oily waste into or upon the navigable waters of the United States, or the waters of the contiguous zone, or which may affect natural resources belonging to, appertaining to, or under the exclusive management authority of the United States, if such discharge causes a film or discoloration of the surface of the water or causes a sludge or emulsion beneath the surface of the water. Violators are subject to substantial civil penalties and/or criminal sanctions including fines and imprisonment.” MI observed that the vessel did not have an oil pollution placard. Recommend obtaining and posting USCG approved oil pollution placard to the satisfaction of the OCMI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2026
Resolved
Each rescue boat and ring life buoy must be marked with approved Type II retroreflective material. MI observed that 02 ring life buoys had deteriorated retroreflective tape. Recommend replacing retroreflective tape on ring life buoys to the satisfaction of the OCMI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 May 2021
Resolved
Vsl does not have a valid Stability Letter
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 May 2021
Resolved
O2 Deck emergency lighting failed to activate. Does not activate automatically or manually.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021
Resolved
All three of the vsl's life buoys were in a non serviceable degraded condition. The required floating water light failed to operate. The required line was missing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2020
Resolved
Both water lubricated shaft bearing are worn with <10% of the lower channels remaining. Renew both bearings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 January 2020
Resolved
All deck hatches are not weather/water tight. Renew gaskets on deck hatches and make tight.
See also Stability Letter Serial: H1-1602487
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 January 2020
Resolved
Numerous leaks in the house in way of electrical and electronic equipment are creating both basic occupational hazards and threaten vital equipment. Make house weather tight.
See also Stability Letter Serial: H1-1602487
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 January 2020
Resolved
Frame 2 in forward peak tank wasted through. Gauge as discussed to find good material. Crop and renew to good metal.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 January 2020
Resolved
Collision bulkhead wasted through and actively leaking water from the forward peak tank to the comparment aft. Area affected runs approx. 6" up to the bulkehad and approximately three feet port and stbd of the CVK. Gauge area as discussed to find good material. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2020
Resolved
Deck wasted through in way of door to weather deck forward. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2020
Resolved
Deck wasted through in way of passenger head piping penetration. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020
Resolved
Hull wasted through in way of the aft port corner of the engine room. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020
Resolved
Hull penetration closed with a non-metallic piece hose clamped in place. Properly close hull penetration.
See also Stability Letter Serial: H1-1602487
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020
Resolved
During this inspection the attending Marine Inspector found evidence to question the general condition of the hull and require addition ultrasonic thickness (U/T) testing overall and in specific areas of concern, 46CFR176.840. The general shots to be carried out as follows:
-10 shots per plate in way of the wind water strake (waterline).
-15 shots per sheet for bottom plate in an evenly spaced pattern.
Areas of specific concern, 5 shots per square foot:
-Several areas of pitting on stern
-Within 6 inches of hull along bottom of collision bulkhead (between compartments 1 and 2)
-Bottom shell from bulkhead at frame seven forward 1' and extending port and stbd of CVK at least two longitudinal bays.
-Near all docking plugs.
-Longitudinal bays in way of sea suction for A/C system in compartment 3.
-Near and under bilge suction in compartment 3
-Under port sewage tank in compartment 5
-In way of sea chest in compartment 5
-In way of 4 sea chests in compartment 6 (engine room)
-Under all machinery in compartment 6 (engine room)
-In way of aft bilge suction compartment 6 (engine
room)
Additionally 5 shots evenly spaced around each sea chest.
A special note is attached to the vessel file that states:
2002: "Vessel hull scantlings do not meet ABS minimum rule thickness. Vessel structure approved by MSC based upon first engineering principals. This hull should be given a zero (0) % corrosion allowance."
Additional research is required, however, at this time any gauging under 3/16” will need to be renewed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2019
Resolved
A Pre-engineered fixed gas fire extinguishing system must have a means to reset devices used to automatically shut down ventilation systems and engines as required by this section. Override to the starboard engine inoperable.
46CFR181.420(b)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2019
Resolved
Each ring buoy on a vessel must be readily accessible. The bow ring life buoy's bracket is missing and is loosely stowed on the bow.
46CFR180.70(b)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2019
Resolved
A bilge suction must be fitted with a suitable strainer. The bilge strainer in the #3 hold is waswted and requires replacement.
46CFR182.510(b)
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 September 2016
Resolved
INSTALL MISSING CORROSION RESISTANT CLIP TO 01
ADULT LIFE JACKET. 46 CFR 160.055-3
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 26 September 2016
Resolved
LABEL 06 LIFE JACKETS WITH VESSEL NAME. 46 CFR 185.604(b)
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 September 2016
Resolved
REPLACE INOPERABLE ANCHOR LIGHT. 46 CFR 183.420
Documentation › Certificates/Documents › Stability Letter
Issued 26 September 2016
Resolved
POST ACCURATE MAXIMUM NUMBER OF PASSENGERS ON UPPER DECK, IN LADDER-WELL TO UPPER DECK. 46 CFR 178.230(b)(1)
Engineering › Fuel Oil Service System › Filter
Issued 26 September 2016
Resolved
REPLACE BROKEN FUEL FILTER PRESSURE GAUGE ON PORT MAIN DIESEL ENGINE. 46 CFR 176.800
Electrical › Electric Supply System (service) › Cable
Issued 26 September 2016
Resolved
INSTALL CHAFFING GEAR ON CABLES PENETRATING OVERHEAD IN HOLD #2. 46 CFR 176.800
Deck/Cargo › Cargo Stowage › General
Issued 26 September 2016
Resolved
SECURE COMPRESSED AIR BOTTLES AND SODA MACHINE COMPRESSOR TO DECK/BULKHEAD IN HOLD #2. 46 CFR 147.60(b)
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 September 2016
Resolved
REMOVE OR SECURE EXTRA BATTERY IN ENGINE ROOM. 46 CFR 183.350
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.