MAURY USCG vessel records
← All vessels

WEST STAR

WEST STAR is a 2002 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in April 2026, along with 26 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 April 2026.

Built
2002
Last inspected
1 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDK5171
563998
Flag
UNITED STATES
Maury page id
psix-563998

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)70.0 ft × 18.0 ft × 5.4 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)70.0 ft × 18.0 ft × 5.4 ft
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES INC · LA CROSSE, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

1 April 2026 COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8316725
20 February 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8082256
17 January 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8065154
26 April 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7905684
10 April 2023 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7665565
25 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7506165
10 May 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7183822
29 January 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6892942
30 October 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6845928
23 September 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6818734
10 October 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6545670
29 September 2018 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552806
2 October 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6265769
26 September 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6010152
26 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5894509
30 March 2016 Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844042

Deficiency record · 26

14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2026 Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: “Discharge of Oil Prohibited. The Federal Water Pollution Control Act prohibits the discharge of oil or oily waste into or upon the navigable waters of the United States, or the waters of the contiguous zone, or which may affect natural resources belonging to, appertaining to, or under the exclusive management authority of the United States, if such discharge causes a film or discoloration of the surface of the water or causes a sludge or emulsion beneath the surface of the water. Violators are subject to substantial civil penalties and/or criminal sanctions including fines and imprisonment.” MI observed that the vessel did not have an oil pollution placard. Recommend obtaining and posting USCG approved oil pollution placard to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 10 April 2026
Resolution: Vessel provided proof of correcting this deficiency. Placard posted on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2026 Resolved
Each rescue boat and ring life buoy must be marked with approved Type II retroreflective material. MI observed that 02 ring life buoys had deteriorated retroreflective tape. Recommend replacing retroreflective tape on ring life buoys to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 10 April 2026
Resolution: Vessel provided proof of correcting this deficiency via photos.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 May 2021 Resolved
Vsl does not have a valid Stability Letter
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 24 May 2021
Resolution: Stability Letter issued by MSC.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 May 2021 Resolved
O2 Deck emergency lighting failed to activate. Does not activate automatically or manually.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 24 May 2021
Resolution: Emergency lighting repaired and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021 Resolved
All three of the vsl's life buoys were in a non serviceable degraded condition. The required floating water light failed to operate. The required line was missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 24 May 2021
Resolution: New life bouys, float light, and line installed on vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2020 Resolved
Both water lubricated shaft bearing are worn with <10% of the lower channels remaining. Renew both bearings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Bearings replaced as part of repower.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 January 2020 Resolved
All deck hatches are not weather/water tight. Renew gaskets on deck hatches and make tight. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Repairs completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 January 2020 Resolved
Numerous leaks in the house in way of electrical and electronic equipment are creating both basic occupational hazards and threaten vital equipment. Make house weather tight. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: House made weathertight during major refit.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 January 2020 Resolved
Frame 2 in forward peak tank wasted through. Gauge as discussed to find good material. Crop and renew to good metal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Structures renewed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 January 2020 Resolved
Collision bulkhead wasted through and actively leaking water from the forward peak tank to the comparment aft. Area affected runs approx. 6" up to the bulkehad and approximately three feet port and stbd of the CVK. Gauge area as discussed to find good material. Crop and renew to good material. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Bulkhead inserted,
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2020 Resolved
Deck wasted through in way of door to weather deck forward. Crop and renew to good material. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Deck inserts completed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2020 Resolved
Deck wasted through in way of passenger head piping penetration. Crop and renew to good material. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Deck inserts completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020 Resolved
Hull wasted through in way of the aft port corner of the engine room. Crop and renew to good material. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Repairs complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020 Resolved
Hull penetration closed with a non-metallic piece hose clamped in place. Properly close hull penetration. See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020 Resolved
During this inspection the attending Marine Inspector found evidence to question the general condition of the hull and require addition ultrasonic thickness (U/T) testing overall and in specific areas of concern, 46CFR176.840. The general shots to be carried out as follows: -10 shots per plate in way of the wind water strake (waterline). -15 shots per sheet for bottom plate in an evenly spaced pattern. Areas of specific concern, 5 shots per square foot: -Several areas of pitting on stern -Within 6 inches of hull along bottom of collision bulkhead (between compartments 1 and 2) -Bottom shell from bulkhead at frame seven forward 1' and extending port and stbd of CVK at least two longitudinal bays. -Near all docking plugs. -Longitudinal bays in way of sea suction for A/C system in compartment 3. -Near and under bilge suction in compartment 3 -Under port sewage tank in compartment 5 -In way of sea chest in compartment 5 -In way of 4 sea chests in compartment 6 (engine room) -Under all machinery in compartment 6 (engine room) -In way of aft bilge suction compartment 6 (engine room) Additionally 5 shots evenly spaced around each sea chest. A special note is attached to the vessel file that states: 2002: "Vessel hull scantlings do not meet ABS minimum rule thickness. Vessel structure approved by MSC based upon first engineering principals. This hull should be given a zero (0) % corrosion allowance." Additional research is required, however, at this time any gauging under 3/16” will need to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Gauging completed and wasted plate replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2019 Resolved
A Pre-engineered fixed gas fire extinguishing system must have a means to reset devices used to automatically shut down ventilation systems and engines as required by this section. Override to the starboard engine inoperable. 46CFR181.420(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Pre-engineered fixed gas fire extignuishing system override was satisfactorily witnessed by attending inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2019 Resolved
Each ring buoy on a vessel must be readily accessible. The bow ring life buoy's bracket is missing and is loosely stowed on the bow. 46CFR180.70(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Ring bouy bracket was installed to vessel. Ring bouy now in compliance with applicable regs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2019 Resolved
A bilge suction must be fitted with a suitable strainer. The bilge strainer in the #3 hold is waswted and requires replacement. 46CFR182.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Worn bilge strainer was replaced by new strainer and was properly installed to bilge piping system.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 September 2016 Resolved
INSTALL MISSING CORROSION RESISTANT CLIP TO 01 ADULT LIFE JACKET. 46 CFR 160.055-3
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl attached new clip to lifejacket on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 26 September 2016 Resolved
LABEL 06 LIFE JACKETS WITH VESSEL NAME. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl labeled life jackets on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 September 2016 Resolved
REPLACE INOPERABLE ANCHOR LIGHT. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl installed new anchor light on the spot.
Documentation › Certificates/Documents › Stability Letter
Issued 26 September 2016 Resolved
POST ACCURATE MAXIMUM NUMBER OF PASSENGERS ON UPPER DECK, IN LADDER-WELL TO UPPER DECK. 46 CFR 178.230(b)(1)
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 25 October 2016
Resolution: Removed inaccurate placards. Posted new one with correct numbers and font size.
Engineering › Fuel Oil Service System › Filter
Issued 26 September 2016 Resolved
REPLACE BROKEN FUEL FILTER PRESSURE GAUGE ON PORT MAIN DIESEL ENGINE. 46 CFR 176.800
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 13 October 2016
Resolution: Removed broken gauge and capped off.
Electrical › Electric Supply System (service) › Cable
Issued 26 September 2016 Resolved
INSTALL CHAFFING GEAR ON CABLES PENETRATING OVERHEAD IN HOLD #2. 46 CFR 176.800
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl installed chaffing gear to protect cables.
Deck/Cargo › Cargo Stowage › General
Issued 26 September 2016 Resolved
SECURE COMPRESSED AIR BOTTLES AND SODA MACHINE COMPRESSOR TO DECK/BULKHEAD IN HOLD #2. 46 CFR 147.60(b)
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 25 October 2016
Resolution: Secured compressed air bottles with ratchet straps.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 September 2016 Resolved
REMOVE OR SECURE EXTRA BATTERY IN ENGINE ROOM. 46 CFR 183.350
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 13 October 2016
Resolution: Removed extra battery from engine room.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.