Records from 2002 to 2026. Most recent: inspection, 1 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
1 April 2026
COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8316725
20 February 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8082256
17 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8065154
26 April 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7905684
10 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7665565
25 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7506165
10 May 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7183822
29 January 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6892942
30 October 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6845928
23 September 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6818734
10 October 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6545670
29 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552806
2 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6265769
26 September 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6010152
26 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5894509
30 March 2016
Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844042
16 July 2015
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5194423
2 December 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4200175
9 September 2010
Drydock Exam · Internal Structural Exam · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3849826
19 January 2010
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3665975
19 January 2010
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3666148
24 February 2009
Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3422438
20 November 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3327438
22 September 2008
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3327419
20 May 2008
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3212096
29 April 2008
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3189845
15 April 2008
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3184609
27 September 2007
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3067215
4 April 2007
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2900494
6 July 2006
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2702545
17 October 2005
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2515369
21 September 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2496078
14 October 2004
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2220482
13 October 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1924034
24 September 2003
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1911204
28 November 2002
Deficiency Check · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1697360
9 January 2002
Initial Construction-Excluding Oversight · Hull Examination · Deadweight Survey · Initial Certification
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1648919
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2026
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: “Discharge of Oil Prohibited. The Federal Water Pollution Control Act prohibits the discharge of oil or oily waste into or upon the navigable waters of the United States, or the waters of the contiguous zone, or which may affect natural resources belonging to, appertaining to, or under the exclusive management authority of the United States, if such discharge causes a film or discoloration of the surface of the water or causes a sludge or emulsion beneath the surface of the water. Violators are subject to substantial civil penalties and/or criminal sanctions including fines and imprisonment.” MI observed that the vessel did not have an oil pollution placard. Recommend obtaining and posting USCG approved oil pollution placard to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 10 April 2026
Resolution: Vessel provided proof of correcting this deficiency. Placard posted on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2026
Resolved
Each rescue boat and ring life buoy must be marked with approved Type II retroreflective material. MI observed that 02 ring life buoys had deteriorated retroreflective tape. Recommend replacing retroreflective tape on ring life buoys to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 10 April 2026
Resolution: Vessel provided proof of correcting this deficiency via photos.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 May 2021
Resolved
Vsl does not have a valid Stability Letter
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 24 May 2021
Resolution: Stability Letter issued by MSC.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 May 2021
Resolved
O2 Deck emergency lighting failed to activate. Does not activate automatically or manually.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 24 May 2021
Resolution: Emergency lighting repaired and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021
Resolved
All three of the vsl's life buoys were in a non serviceable degraded condition. The required floating water light failed to operate. The required line was missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 24 May 2021
Resolution: New life bouys, float light, and line installed on vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2020
Resolved
Both water lubricated shaft bearing are worn with <10% of the lower channels remaining. Renew both bearings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Bearings replaced as part of repower.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 January 2020
Resolved
All deck hatches are not weather/water tight. Renew gaskets on deck hatches and make tight.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Repairs completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 January 2020
Resolved
Numerous leaks in the house in way of electrical and electronic equipment are creating both basic occupational hazards and threaten vital equipment. Make house weather tight.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: House made weathertight during major refit.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 January 2020
Resolved
Frame 2 in forward peak tank wasted through. Gauge as discussed to find good material. Crop and renew to good metal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Structures renewed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 January 2020
Resolved
Collision bulkhead wasted through and actively leaking water from the forward peak tank to the comparment aft. Area affected runs approx. 6" up to the bulkehad and approximately three feet port and stbd of the CVK. Gauge area as discussed to find good material. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Bulkhead inserted,
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2020
Resolved
Deck wasted through in way of door to weather deck forward. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Deck inserts completed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 January 2020
Resolved
Deck wasted through in way of passenger head piping penetration. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Deck inserts completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020
Resolved
Hull wasted through in way of the aft port corner of the engine room. Crop and renew to good material.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Repairs complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020
Resolved
Hull penetration closed with a non-metallic piece hose clamped in place. Properly close hull penetration.
See also Stability Letter Serial: H1-1602487
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2020
Resolved
During this inspection the attending Marine Inspector found evidence to question the general condition of the hull and require addition ultrasonic thickness (U/T) testing overall and in specific areas of concern, 46CFR176.840. The general shots to be carried out as follows:
-10 shots per plate in way of the wind water strake (waterline).
-15 shots per sheet for bottom plate in an evenly spaced pattern.
Areas of specific concern, 5 shots per square foot:
-Several areas of pitting on stern
-Within 6 inches of hull along bottom of collision bulkhead (between compartments 1 and 2)
-Bottom shell from bulkhead at frame seven forward 1' and extending port and stbd of CVK at least two longitudinal bays.
-Near all docking plugs.
-Longitudinal bays in way of sea suction for A/C system in compartment 3.
-Near and under bilge suction in compartment 3
-Under port sewage tank in compartment 5
-In way of sea chest in compartment 5
-In way of 4 sea chests in compartment 6 (engine room)
-Under all machinery in compartment 6 (engine room)
-In way of aft bilge suction compartment 6 (engine
room)
Additionally 5 shots evenly spaced around each sea chest.
A special note is attached to the vessel file that states:
2002: "Vessel hull scantlings do not meet ABS minimum rule thickness. Vessel structure approved by MSC based upon first engineering principals. This hull should be given a zero (0) % corrosion allowance."
Additional research is required, however, at this time any gauging under 3/16” will need to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2020
Resolved 8 April 2021
Resolution: Gauging completed and wasted plate replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2019
Resolved
A Pre-engineered fixed gas fire extinguishing system must have a means to reset devices used to automatically shut down ventilation systems and engines as required by this section. Override to the starboard engine inoperable.
46CFR181.420(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Pre-engineered fixed gas fire extignuishing system override was satisfactorily witnessed by attending inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2019
Resolved
Each ring buoy on a vessel must be readily accessible. The bow ring life buoy's bracket is missing and is loosely stowed on the bow.
46CFR180.70(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Ring bouy bracket was installed to vessel. Ring bouy now in compliance with applicable regs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2019
Resolved
A bilge suction must be fitted with a suitable strainer. The bilge strainer in the #3 hold is waswted and requires replacement.
46CFR182.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 30 October 2019
Resolution: Worn bilge strainer was replaced by new strainer and was properly installed to bilge piping system.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 September 2016
Resolved
INSTALL MISSING CORROSION RESISTANT CLIP TO 01
ADULT LIFE JACKET. 46 CFR 160.055-3
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl attached new clip to lifejacket on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 26 September 2016
Resolved
LABEL 06 LIFE JACKETS WITH VESSEL NAME. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl labeled life jackets on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 September 2016
Resolved
REPLACE INOPERABLE ANCHOR LIGHT. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl installed new anchor light on the spot.
Documentation › Certificates/Documents › Stability Letter
Issued 26 September 2016
Resolved
POST ACCURATE MAXIMUM NUMBER OF PASSENGERS ON UPPER DECK, IN LADDER-WELL TO UPPER DECK. 46 CFR 178.230(b)(1)
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 25 October 2016
Resolution: Removed inaccurate placards. Posted new one with correct numbers and font size.
Engineering › Fuel Oil Service System › Filter
Issued 26 September 2016
Resolved
REPLACE BROKEN FUEL FILTER PRESSURE GAUGE ON PORT MAIN DIESEL ENGINE. 46 CFR 176.800
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 13 October 2016
Resolution: Removed broken gauge and capped off.
Electrical › Electric Supply System (service) › Cable
Issued 26 September 2016
Resolved
INSTALL CHAFFING GEAR ON CABLES PENETRATING OVERHEAD IN HOLD #2. 46 CFR 176.800
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 September 2016
Resolution: Vsl installed chaffing gear to protect cables.
Deck/Cargo › Cargo Stowage › General
Issued 26 September 2016
Resolved
SECURE COMPRESSED AIR BOTTLES AND SODA MACHINE COMPRESSOR TO DECK/BULKHEAD IN HOLD #2. 46 CFR 147.60(b)
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 25 October 2016
Resolution: Secured compressed air bottles with ratchet straps.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 September 2016
Resolved
REMOVE OR SECURE EXTRA BATTERY IN ENGINE ROOM. 46 CFR 183.350
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 13 October 2016
Resolution: Removed extra battery from engine room.
Communications › Radio Communications › EPIRB
Issued 29 April 2008
Resolved
Vessel is restricted to Lakes, Bays, and Sounds route until expired battry in the EPIRB is replaced.
Action required: 705 - Other - as specified
Resolved 5 May 2008
Resolution: CLEARED
Engineering › Bilge Water Management System › Piping
Issued 29 April 2008
Resolved
Properly lable bilge system/valves to include operating procedures.
Action required: 705 - Other - as specified
Due 5 May 2008
Resolved 5 May 2008
Resolution: CLEARED
Fire Fighting › Fire Pumps › Capacity
Issued 4 April 2007
Resolved
Prove proper operation of Fire Pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2007
Resolved 11 April 2007
Resolution: Email
Communications › Radio Communications › EPIRB
Issued 4 April 2007
Resolved
Replace EPIRB hydrostatic release and register EPIRB/show proof of current registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2007
Resolved 6 April 2007
Resolution: e-mail/phone
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 4 April 2007
Resolved
Provide complete first aid kit onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2007
Resolved 6 April 2007
Resolution: Email/phone
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 4 April 2007
Resolved
Prove proper operation of Ship service diesel F/O lift pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2007
Resolved 6 April 2007
Resolution: e-mail/phone
Lifesaving › Lifejacket/PFD (General) › Size
Issued 4 April 2007
Resolved
Disable/replace and make lifejacket stowage lockers incapable of being locked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2007
Resolved 6 April 2007
Resolution: e-mail/phone
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 4 April 2007
Resolved
Permanently affix and paint in contrasting color, vessel's draft marks. Complete at next dry-dock.
Action required: 705 - Other - as specified
Due 1 September 2007
Resolved 22 October 2008
Resolution: Verified draft marks were permanently affixed to vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 July 2006
Resolved
Provide alcohol test kit onboard the vessel for post SMI testing.
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 11 July 2006
Resolution: Cleared
Lifesaving › Hand Flares › Quantity
Issued 6 July 2006
Resolved
Provide required flares for LCW route.
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 6 July 2006
Resolution: Cleared
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 October 2005
Resolved
Provide requirements outlined in 46CFR16.401 for Employee Assistance Program. When the master was asked about the program, he stated that he wasn't aware of it. They had ASAP's information onboard, but didn't know about the program. Instructed master and crew on the EAP and required them to get material from ASAP and conduct training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 3 November 2005
Resolution: REVIEWED EAP, ALL SAT. CREW HAS BEEN TRAINED AND POSTERS HAVE BEEN POSTED.
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 17 October 2005
Resolved
Provide information for after-hour testing in case of a SMI. Master didn't know where to go for testing if they had a SMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 3 November 2005
Resolution: REVIEWED APPROPRIATE INFORMATION FOR AFTER HOUR CARE. ALL SAT.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 October 2005
Resolved
Repair broken lanyards for all watertight deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 3 November 2005
Resolution: REPAIRED.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 October 2005
Resolved
Replace tag lines on all 3 ring life buoys onboard. Every line was fraying to a point of parting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 3 November 2005
Resolution: INSTALLED NEW RING BUOYS.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 October 2005
Resolved
Properly place retro-reflective tape at 90* angles on ring buoys as discussed. All the retro had been moved to one side next to each other.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 3 November 2005
Resolution: INSTALLED NEW RING BUOYS.
Accommodation/Occupational Safety › Ventilation › General
Issued 17 October 2005
Resolved
Work PORT AFT engine room vent so it will close 100%. Salt build up on hinges prevented the vent from closing 100%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 3 November 2005
Resolution: CORRECTED.
Communications › Radio Communications › EPIRB
Issued 17 October 2005
Resolved
Prior to the carriage of passengers on a Limited Coastwise Route, repair EPIRB antenna. Found the antenna insulation jacket broke and missing a 2 inch section. Repair shop said it would take a week to repair, so reduced rout to L, B, & S until EPIRB is back onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2005
Resolved 3 November 2005
Resolution: NEW EPIRB ONBOARD. ANTENNA REPAIRED.
Construction/Loadline › Hull › Hull Plating
Issued 21 September 2005
Resolved
De-rust/remove scale in way of forepeak keel.
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 17 October 2005
Resolution: ENTIRE AREA HAS BEEN CLEANED AND PAINTED.
Construction/Loadline › Hull › Hull Plating
Issued 21 September 2005
Resolved
Properly prepare and coat areas of bilge where coating system is failing.
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 17 October 2005
Resolution: BILGE AREA HAVE BEEN CLEANED AND PAINTED.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 October 2004
Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Due 14 November 2004
Resolved 27 October 2004
Resolution: FAX DOCUMENT.
Communications › Radio Communications › EPIRB
Issued 14 October 2004
Resolved
REPLACE 406 MHZ EPIRB HYDROSTATIC RELEASE.
Due 1 November 2004
Resolved 9 November 2004
Resolution: NEW EXP. 11/06. PHONECON WITH EARL OUTLAND.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 October 2004
Resolved
PROVIDE PROOF OF ANNUAL SERVICE OF FIXED FIREFIGHTING SYSTEM PRIOR TO CARRIAGE OF PASSENGERS.
Due 15 October 2004
Resolved 14 October 2004
Resolution: FAX DOCUMENTATION.
Engineering › Steering Gear System
Issued 23 September 2003
Resolved
REPAIR SEVERLY BENT PORT RUDDER. LEGACY COMPONENT DESC: Rudder
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2003
Resolved 24 September 2003
Operations/Management
Issued 15 November 2002
Resolved
DESIGNATE SENIOR DECKHAND IN WRITING.
Action required: 705 - Other - as specified
Due 29 November 2002
Resolved 28 November 2002
Resolution: OPERATOR DESIGNATED SENIOR DECKHAND IN WRITING.
Operations/Management › Drills/Instruction
Issued 15 November 2002
Resolved
REVISE EMERGENCY INSTRUCTIONS IAW CG REGULATIONS
Action required: 705 - Other - as specified
Due 29 November 2002
Resolved 28 November 2002
Resolution: OPERATOR PROVIDED REVISED EMERGENCY PROCEDURES.
Documentation › Manuals/Policy Documentation
Issued 15 November 2002
Resolved
PROVIDE A COPY OF 46CFR SUBCHAPTER T.
Action required: 705 - Other - as specified
Due 29 November 2002
Resolved 28 November 2002
Resolution: OPERATOR PROVIDED COPY OF 46CFR "T"
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 15 November 2002
Resolved
SECURE "OASIS DRINK MACHINE" TO COUNTERTOP OR PLACE IN A LOWER LOCATION. LEGACY COMPONENT DESC: Recreation Space
Action required: 705 - Other - as specified
Due 29 November 2002
Resolved 28 November 2002
Resolution: OPERATOR SECURED OASIS DRINK MACHINE USING METAL STRAPS.
Documentation › Certificates/Documents
Issued 29 October 2002
Resolved
PROVIDE FCC STATION AND SAFETY LICENSE. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Lifesaving › Lifebuoys
Issued 29 October 2002
Resolved
PROVIDE 60FT OF POLYPROPELYNE LINE AND RETROFLECTIVE TAPE. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Documentation › Certificates/Documents
Issued 29 October 2002
Resolved
PROVIDE DOCUMENTATION TO REFLECT NAME CHANGE OF VSL. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: WITNESED PAPERWORK SENT TO NVDC
Communications › Radio Communications
Issued 29 October 2002
Resolved
REGISTER EPIRB WITH NOAA LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 29 October 2002
Resolved
SECURE BOTTOM OF LADDER TO DECK IN ENGINE ROOM.
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Operations/Management › Drills/Instruction
Issued 29 October 2002
Resolved
CONDUCT DRILL IN PRESENCE OF MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Action required: 705 - Other - as specified
Resolved 15 November 2002
Resolution: ATTENDED VSL ON 15NOV TO CONDUCT DRILLS ALL SAT.