Records from 2002 to 2018. Most recent: inspection, 6 October 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
6 October 2018
Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 6556747
28 September 2018
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6550677
20 January 2010
Hull Examination · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3665908
9 July 2009
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 3529335
12 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3432404
20 May 2008
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3211953
24 March 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3170326
28 January 2008
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3138412
19 March 2007
Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2890731
18 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2892245
6 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2597097
21 February 2006
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2589194
13 October 2005
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2513897
19 January 2005
Initial Certification · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2277848
19 January 2005
Plan Review "T" Boat
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2349352
27 May 2004
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2079629
15 May 2003
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2156727
24 April 2002
Hull Examination · Construction Oversight · Simplified Stability Test · Initial Certification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1608959
Lifesaving › Hand Flares › Expired
Issued 20 January 2010
No resolution recorded
Provide (1) additional orange smoke signal prior to operating.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 January 2010
No resolution recorded
Complete required drills and properly log in presence of CG Marine Inspector prior to operating.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 January 2010
No resolution recorded
Renew expired medications in 1st aid kit prior to operating.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 January 2010
No resolution recorded
Renew battery for waterlight prior to operating.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Construction/Loadline › Hull › Weld
Issued 20 January 2010
No resolution recorded
Grind and reweld sections of port and starboard pontoons as marked prior to completing credit dry dock exam.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 20 January 2010
No resolution recorded
Renew wasted plywood decking from the stem to the 3rd transverse stiffener prior to completing credit dry dock exam.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Weld
Issued 20 January 2010
No resolution recorded
Renew pontoon inspection port securing devices as needed prior to completing credit dry dock exam.
Action required: 705 - Other - as specified
Due 20 January 2010 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 20 January 2010
Resolved
Properly clean both pontoon hulls and make available for inspection prior to completing credit dry dock.
Action required: 705 - Other - as specified
Due 20 January 2010
Resolved 27 January 2010
Resolution: cleaned
Construction/Loadline › Penetrations › Gasket
Issued 20 May 2008
Resolved
Make plug for each pontoon compartment serviceable and capable of being removed for visual inspection of pontoon internal.
Action required: 705 - Other - as specified
Due 20 June 2008
Resolved 25 June 2008
Lifesaving › Lifebuoys › Serviceable
Issued 24 March 2008
Resolved
Replace un-servicable life ring buoy.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2008
Resolution: Master of vessel faxed a receipt of purchase for life ring.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 March 2008
Resolved
re-stencil stowage location for all life jackets
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 12 March 2009
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 22 February 2006
Resolved
Emergency check-off list is unreadable and must be renewed.
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 6 March 2006
Resolution: Cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 February 2006
Resolved
Vessels portable fire extinguishers are past due for annual servicing.
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 6 March 2006
Resolution: Cleared.
Operations/Management › Drills/Instruction › Fire
Issued 19 January 2005
Resolved
POST EMERGENCY INSTRUCTION (46 CFR 185.510)
Due 26 January 2005
Resolved 1 February 2005
Resolution: RCV FAX FROM O/O INSTRUCTION HAD BEEN POSTED
Lifesaving › Hand Flares › Quantity
Issued 19 January 2005
Resolved
PROVIDE THREE ORANGE DAY FLARES (46 CFR 180.68)
Due 26 January 2005
Resolved 1 February 2005
Resolution: RCVD FAX FROM O/O THAT FLARES WERE PLACED ON VSL
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 January 2005
Resolved
POST LIFE JACKETS DONNING PLACARDS. (46 CFR 188.516)
Due 26 January 2005
Resolved 1 February 2005
Resolution: RCVD FAX FROM O/O THAT PLACARD WAS POSTED ON VSL
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 January 2005
Resolved
REPLACE PORTABLE FIRE EXTINGUISHERS
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2005
Resolved 19 January 2005
Resolution: BOTH PORTABLE FIRE EXTINGUISHERS WERE REPLACED
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 January 2005
Resolved
PROVIDE ONE PORTABLE BATTERY LIGHT (46 CFR 183.430)
Due 26 January 2005
Resolved 19 January 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 January 2005
Resolved
PROVIDE ONE PORTABLE BATTERY LIGHT (46 CFR 183.430)
Due 26 January 2005
Resolved 2 February 2005
Resolution: RCVD FAX FROM O/O THAT PORTABLE LIGHT HAD BEEN ADDED TO VSL
Construction/Loadline › Penetrations › Pipe Flange
Issued 19 January 2005
Resolved
Open and provide access to all pontoon inspection ports. (46 CFR 176)
Due 26 January 2005
Resolved 10 February 2005
Resolution: All pontoon inspection ports open and inspected