Inspection history · 20
23 July 2026
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8449266
23 April 2026
In-Service Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8355023
8 May 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8130743
24 July 2024
In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7965582
1 July 2024
Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7947777
5 May 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7809653
4 May 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679787
21 March 2023
Type not recorded
No type recorded · USCGC OLIVER BERRY (WPC 1124) · USCG Oceania District (CGD-O) · Activity 7658074
4 October 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571770
25 May 2022
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7459429
3 May 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7444094
7 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7300812
1 April 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170117
11 August 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7030528
13 March 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6926259
9 September 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6808819
24 April 2018
DAPI Audit · Administrative Inspection · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398740
20 August 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6255752
30 May 2017
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6160550
2 May 2016
DAPI Audit · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867646
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 23 July 2026
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The engine room are not vapor tight due to unsealed cable penetrations, door gaskets in need of repair, and inadequate ventilation closure devices.
46 CFR 177.405
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2026
Resolved 12 August 2026
Resolution: Cable penetrations were filled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 July 2026
Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspection and in accordance with manufacturer's instructions. Two fire extinguishers are stored under the operating station console without being secured.
46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2026
Resolved 12 August 2026
Resolution: Extinguishers were mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2026
Resolved
Electric cables must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart.
46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2026
Resolved 12 August 2026
Resolution: Cables have been properly supported with metal bands.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2025
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] engine motor oil hose section in way of fuel filter/fwd engine bulkhead worn and wasted. Hose section requires renewal. 46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 3 July 2025
Resolution: Port engine oil drain hose renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2024
Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel requires amended COI after New to Zone In-Service Inspection. 46 CFR 176.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: COI amended to reflect all changes required to operate in Maui waters.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 24 July 2024
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel requires updated COD due to change of ownership. 46 CFR 67.313(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: New COD received.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 July 2024
Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel could not produce current FCC station license during NTZ/annual inspection on 24JUL24. Provide correct FCC license prior to carriage of passengers. 47 CFR 80.405
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2024
Resolution: FCC Station authorization and safety radio license received
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 July 2024
Resolved
Each vessel that operates on the high seas, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel requires presence of EPIRB with valid registration and battery expiration date. 46 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2024
Resolution: New EPIRB installed onto vessel with valid registration.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 July 2024
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: a light to indicate discharge, and and audible alarm that sounds upon discharge. Starboard visual/audible and port audible alarms at operating station not operational. Provide both visual and audible alarms for port and starboard pre-engineered fixed gas extinguisher at operating station. 46 CF 181.420(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Visual and audible alarms confirmed for port and starboard pre-engineered fixed gas extinguisher at operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a) and other provisions of this section. Operating station missing (01) 10 B:C portable extinguisher. 46 CFR 181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
Resolution: New 10 B:C portable fire extinguisher installed at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. Port "head" visual/audible alarm and Stbd engine compartment visual light, for high water bilge alarms not operational. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Port "head" and starboard engine compartment bilge high water floats replaced and functioning with visual/audio alarms at the operating station.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 24 July 2024
Resolved
The employer shall provide an Employee Assistance Program for all crew members. Vessel's O/O has an Employee Assistance Program(EAP)as part of the company's
chemical testing program, but needs to provide paperwork
for satisfactory evidence of drug and alcohol program. 46 CFR 16.401
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Vessel rep provided EAP and Drug/alcohol policy documents for vessel and all employees, with up to date drug and alcohol awareness re-certification.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 July 2024
Resolved
All fiber reinforced plastic vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type installed in accordance with 76.27 in subchapter H of this chapter in accommodation spaces and service spaces. Vessel does not a have smoke activated fire detection system for required spaces. Provide smoke activated fire detection system and install to the satisfaction of the attending marine inspector. 46 CFR 177.410(c)(3)(ii)
Action required: 705 - Other - as specified
Resolved 9 May 2025
Resolution: Special consideration for interconnected smoke activated fire detection system approved. Document attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 August 2024
Resolution: Written report received and placed on board
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2024
Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, copies of the following plans,that are applicable to the vessel as determined by the OCMI: On sailing vessels:
(i) Masts, including integration into the ship's structure; and
(ii) Rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and connections of the standing rigging.
Provide updated PMP and rigging plan for vessel. 46 CFR 177.202(b)(12)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2024
Resolution: Updated Sail rigging PMP provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and scenario and training topics. Vessel unable to provide drill/training logs. 46 CFR 185.520(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2024
Resolution: Crew conducted drills and training and properly logged on board vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 July 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2024
Resolution: Updated charts received and placed on vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 July 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Provide two portable lights. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 August 2024
Resolution: Portable lights installed at operating station and in port and starboard machinery space.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 September 2021
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present.
MI found vapor seal no serviceable to Engine compartment doors. In addition, port engine compartment securing latch is broken door is not fully secured. Vessel needs to provide serviceable latch and prove vapor seal.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 21 September 2021
Resolution: Vessel installed new vapor seals along engine compartment doors and repaired door latches so they are capable of fully securing the door.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 7 September 2021
Resolved
Marine Sanitation Devices shall be secure to prevent overboard discharge until in designated areas.
MI found both sewage holding tank overboard valves to have no have securing capabilities. Vessel shall prove valves can be locked and the master is fully aware when the valves are shifted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 21 September 2021
Resolution: Vessel removed handles from overboard discharge valves and placed them with in the operation station under the Master's supervision.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 September 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separation from adult life jackets. MI found no separation between adult and child life jackets. Prove Life jackets have some type of separation
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 21 September 2021
Resolution: Vessel seperated life jacket sizes by installing a divider.
04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 7 September 2021
Resolved
Remote F/O shut off valves and life jacket stowage location must be marked. Provide labeling for shut off valves and life jacket location.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 21 September 2021
Resolution: Vessel has clearing labeled locations of fuel shut off valves and life jacket stowage.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 April 2018
Resolved
Each portable fire extinguisher is required to be inspected annually by a certified technician. The portable dry chem had not been inspected/serviced with in one year. Provide a inspected/serviced extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2018
Resolved 25 April 2018
Resolution: A new extinguisher with proper documentation was provided immediately after deficiency was identified.