Records from 2010 to 2026. Most recent: inspection, 24 July 2026.
Inspection history · 26
24 July 2026
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8445797
14 June 2026
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8406942
28 May 2026
Administrative Inspection · Vessel Attendance · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8382581
13 May 2026
Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8361756
19 March 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8096271
4 February 2025
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8074381
10 April 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7893103
15 February 2024
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7866258
19 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7692465
22 March 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7642770
18 April 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7433104
21 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7202586
13 May 2021
Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7196822
6 May 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7190577
16 June 2020
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6977780
18 March 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6929085
18 March 2020
Deficiency Check · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6929151
6 June 2019
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6705872
25 February 2019
Deficiency Check · In-Service Inspection · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6631962
3 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6404595
1 June 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6162182
31 May 2017
Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6161346
1 May 2017
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6139133
8 August 2016
Damage Survey · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5966728
8 August 2016
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5969442
14 March 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5833225
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2026
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge or other spaces subject to flooding from sea water piping within the space. Vessel's bilge high level alarms were inoperable. Crew is to monitor the bilges every 30 minutes while underway.
46 CFR 182.530(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 28 May 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 13 May 2026
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 May 2026
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessel's VHF-DSC radiotelephone does not have the GPS connected to it.
47 CFR 80.905(a)(1)
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 28 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel could not prove their charts were up-to-date.
46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 28 May 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2026
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate the recovery of persons who have fallen overboard. Vessel failed MOB drill because they took too long to recover Oscar from the water. Tried a 2nd time and was successful.
46 CFR 185.520(a)
Action required: 10 - Deficiency Rectified
Resolved 13 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2026
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Waterlight was not secured around the body of the ring life buoy.
46 CFR 180.70(d)(2)
Action required: 10 - Deficiency Rectified
Resolved 13 May 2026
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 April 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
The vessel only had two fire buckets with the words "FIRE BUCKET" unreadable due to corrosion. Replace to the satisfaction of the attending marine inspector.
-46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 17 April 2025
Resolution: All fire buckets on board were replaced with three new fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard was not attached to the body of the life buoy and no more than 2 feet long. Replace to the satisfaction of the attending marine inspector.
-46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 17 April 2025
Resolution: Lanyard replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 April 2025
Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The vessel's electronic charts have not been updated in 12 months. Rectify to the satisfaction of the attending marine inspector.
- 46CFR184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 17 April 2025
Resolution: New charting system with updated charts installed.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 April 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. There was excessive accumulation of oily water in the engine room bilge. The operator will clean out the bilge to allow the attending marine inspector to reinspect the space.
-46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 17 April 2025
Resolution: Bilge cleaned out. Technician found water ingress points at engine room drain valve and rudder thru-hull fitting. All repaired satisfactorily. No further water ingress noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2025
Resolved
Individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. The bilge pump in the engine room is not fitted with a check valve. Repair to the satisfaction of the attending marine inspector.
-46 CFR 182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2025
Resolved 17 April 2025
Resolution: New bilge pump with check valve installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 March 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The vessels main propulsion engine was missing a guard on the engine pulley. 46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 20 March 2024
Resolution: Received objective evidence from vessel rep [name withheld] attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 March 2024
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a
serial number. The vessel was missing an expiration date for the battery. 46 CFR 185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 20 March 2024
Resolution: Received objective evidence from vessel rep [name withheld] attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery bilge. Bilge alarm for the engine room machinery space did not activiate visual and audible alarm at the operating station. Must be rectifiedf Prior to the Carriage of Passengers.
46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2022
Resolved 29 April 2022
Resolution: Vessel was able to produce audible and visual high bilge alarm at the operating station.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 June 2021
Resolved
For each marine casualty required to be reported by 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involced in the casualty. Alcohol test strips are espired. Replace with new strips.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2021
Resolved 8 June 2021
Resolution: Company procedures state crew will immediately report for testing after incident. Max time from furthest point of route to facility is 30 minutes.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 June 2021
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required. Operator could not produce radio license. Demonstrate proper certification of an operator. 47 CFR 80.155
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2021
Resolved 10 June 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 June 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Only one light provided onboard. Demonstrate provision of 2 lights onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 9 June 2021
Resolution: One additional flashlight provided onboard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 May 2021
Resolved
A hatch cover must have securing devices. Starboard engine room hatch did not have securing device. Provide securing device for starboard engine room hatch.
46 CFR 179.360(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 7 June 2021
Resolution: Received photos (included) proving the installation of a securing device/handle for the starboard engine room hatch. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2021
Resolved
Structural Other- A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry-dock examination and an internal structural at least once every two years. Vessels owner failed to schedule a dry-dock by the due date of 31 March 2021, notification was not made to the OCMI until 5 May 2021. Vessel is to immediately schedule a dry-dock and is to not be operated until completion of the examination to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 May 2021
Resolution: Vessel completed credit drydock exam to the satisfaction of attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2020
Resolved
On a vessel of at least 7.9meters (26feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Bilge pump tested satisfactory, high level alarm inoperable.Prior to getting underway, continuos bilge is checked for water, vessel operates for an hour, bilges checked upon return.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 19 June 2020
Resolution: Visual and audible indicators operable on bilge system.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 June 2020
Resolved
All cable and wire must be protected from the weather. Dead end wires on conning station and missing coverings on conning station. Loose and dead end wires in engine compartment.
46CFR183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 19 June 2020
Resolution: Dead end wires removed and holes covered up on conning station.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 16 June 2020
Resolved
Vessels operated solely within 20NM of land must be equipped with a VHF-DSC radiotelephone installation. VHF inoperable. Vessel restricted to <1000ft from shore.
47CFR80.905
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 19 June 2020
Resolution: Vessel replaced VHF Radio. Tested Sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. Navigation lights are not protected from weather, have open electrical. Nav lights are operational.
46CFR183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 19 June 2020
Resolution: Both nav lights replaced with new LED lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 June 2020
Resolved
Provide Safety Radio Certificate
47CFR80.401
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 30 June 2020
Resolution: Vessel rep provided valid Safety Radio Certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2019
Resolved
Must provide satisfactory evidence of the required servicing to the Marine Inspector. If any of the equipment has not been properly maintained a qualified servicing facility must preform the required inspections.
The fire extinguishers and Fire Boy were past due for inspection. Inspection needs to be completed prior to issuance of COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2019
Resolved 28 June 2019
Resolution: Conducted an operation test and a visual inspection of the system. Passed all required inspections.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2019
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separate from adult life jackets.
Child life jackets were stowed with no markings indicating what they were and how many.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2019
Resolved 18 June 2019
Resolution: Lifejackets were properly stored
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 June 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 18 June 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 June 2019
Resolved
Alcohol testing required to be conducted within 2 hours of a serious marine incident.
No alcohol strips were produced on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 18 June 2019
Resolution: Alcohol strips are onboard
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 June 2019
Resolved
Each vessel must be marked with official number marked in block-type Arabic not less than 3 inches in height and clearly visible on some interior structural part of the hull. Must be permanently affixed. Name of the vessel must be clearly marked on port and starboard bow and stern of the vessel. The Hailing port must be marked on some clearly visible exterior part of the stern.
Vessel was painted and no markings were visible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 18 June 2019
Resolution: All required marking were properly placed as required
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 June 2019
Resolved
Each hatch must have a securing device.
Hatch cover starboard side above the engine room had no securing device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 18 June 2019
Resolution: Hatch was able to properly secure.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 May 2018
Resolved
A VESSEL CARRYING NOT MORE THAN 49 PASSENGERS 26 FEET UP TO 65 FEET IN LENGTH MUST HAVE 1 FIXED POWER PUMP AND 1 PORTABLE HAND PUMP OR, 1 FIXED HAND PUMP AND 1 PORTABLE HAND PUMP. VESSEL DOES NOT HAVE A PORTABLE HAND PUMP ONBOARD. A SECOND POWER PUMP MAY BE ACCEPTABLE ALTERNATIVE TO A HAND PUMP IF IT IS SUPPLIED BY A SOURCE OF POWER INDEPENDENT OF THE FIRST POWER BILGE PUMP.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2018
Resolved 5 June 2018
Resolution: Vessel obtained portable hand pump
Engineering › Bilge Water Management System › Interface Detector
Issued 22 May 2018
Resolved
A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE A HIGH WATER LEVEL IN NORMALLY UNMANNED SPACES. VESSELS VISUAL INDICATOR IS INOPERATIVE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2018
Resolved 5 June 2018
Resolution: Satisfactory operation of bilge visual alarm demonstrated to Marine Inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2018
Resolved
EACH RING LIFE BOUY WITH A FLOATING WATERLIGHT MUST HAVE A LANYARD SECURING THE WATERLIGHT AROUND THE BODY OF THE RING LIFE BOUY. VESSEL WATERLIGHT ONLY SECURED TO THE STRAP OF THE RING LIFE BOUY AND NOT WRAPPED AROUND THE BODY OF THE RING LIFE BOUY.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2018
Resolved 5 June 2018
Resolution: New waterlight installed and correctly attached to ring buoy.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 May 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2018
Resolved 5 June 2018
Resolution: EAP information posted behind plexiglass.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 June 2017
Resolved
Alcohol test strips expired. Alcohol testing of each individual must be conducted within 2 hours of when the serious marine incident occured. Vessel operators must provide alcohol test strips. Vessel restricted to be within 2 hours of alcohol testing facility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2017
Resolved 7 June 2017
Resolution: Vessel rep provided unexpired alcohol test strips for the vessel.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 June 2017
Resolved
Vessel without applicable U.S. Coast Pilot onboard. A vessel must carry adequate and up to date U.S. Coast Pilot or similar publication. Vessel operator must provide Coast Pilot or extracts to attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 7 June 2017
Resolution: Vessel rep provided applicable, up-to-date Coast Pilot extracts.
Engineering › Steering Gear System › Valve, Control
Issued 8 August 2016
Resolved
While underway vessel steering became sluggish and intermittent, operator was able to safely dock vessel and disembark passenger. Hydraulic leaks in the steering gear compartment and at the helm were discovered. System is to be repaired/replaced in kind prior to vessel operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 18 August 2016
Resolution: Vessel steering gear has been replaced in kind. Inspected repairs and conducted operational tests while pier side and underway. All inspected items and tests were considered satisfactory.
Engineering › Steering Gear System › Piping
Issued 8 August 2016
Resolved
Vessel rep stated the entire steering system may be replaced, as noted on CG-835 any changes to piping must be IAW 46 CFR 182.710 (c).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 18 August 2016
Resolution: No piping components were changed during repairs.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 March 2016
Resolved
The number of lifejackets is not clearly marked for each stowage container. Make correctionsl to sign to reflect numbers in each container.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Corrected on the spot
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 March 2016
Resolved
Placards do not reflect donning instructions for multiple styles of life jackets carried onboard. Provide donning instructions for each style.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Corrected on the spot
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 March 2016
Resolved
Alcohol testing strips expired. 46 cfr 4.06-3 (a)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 23 March 2016
Resolution: Vessel provided proof of purchase for alcohol testing strips