The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for OREGON, retrieved 18 September 2026. mauryrecords.com/v/psix-564697.html
Documentation record
Tonnage as PSIX records it38727 - Simplified, Gross Ton 26124 - Simplified, Net Ton 74204 - Dead Weight, Metric Ton 84292 - Displacement, Metric Ton 38727 - Convention (Subpart B), Gross Ton 26124 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
28 June 2017Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6188033
20 December 2009Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3653127
29 December 2008Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3383673
4 May 2006PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2640189
7 July 2005Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2418942
14 December 2004PII Safety Exam · Ballast Water Examination
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 June 2017Resolved
0750: The fire integrity of fire divisions shall be maintained at openings and penetrations. A 6 inch crack was found at the top left corner of the forward door to the ECR and 4 inch crack was found on the top left corner aft door to the ECR, compromising the integrity of the ECR fire boundary, 74 SOLAS (14 cons) II-2/9.3., 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 June 2017Resolved
1430: The condition of the ship and its equipment shall be maintain to conform with the provision of he present regulations, whenever a defect is discovered the Master shall report at the earliest opportunity to the administration. A soft patch and pinhole leak were found on the S/W cooling line for the generator #1, 74 SOLAS (14 cons) , I/II, 40AC.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 28 June 2017Resolved
2520: The company should ensure that any non-conformity is reported, appropriate action is taken and records of these activities is maintained. The SMS should ensure hazardous situations re reports to the company. The crew is using unsafe procedures to test the smoke detector over the main engine. The heat detector in the E/R workshop has an incorrect smoke detector label near it. See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
2550: Whenever a defect is discovered which affects the safety of the ship the Master shall report to the administration. A 4cm crack and a 6 cm crack were found on the steel plating of the door of the incinerator, 74 SOLAS (14 cons), I/11, 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National