Records in 2017. Most recent: inspection, 28 June 2017.
Documentation record
Tonnage as PSIX records it38727 - Simplified, Gross Ton
26124 - Simplified, Net Ton
74204 - Dead Weight, Metric Ton
84292 - Displacement, Metric Ton
38727 - Convention (Subpart B), Gross Ton
26124 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 June 2017
Resolved
0750: The fire integrity of fire divisions shall be maintained at openings and penetrations. A 6 inch crack was found at the top left corner of the forward door to the ECR and 4 inch crack was found on the top left corner aft door to the ECR, compromising the integrity of the ECR fire boundary, 74 SOLAS (14 cons) II-2/9.3., 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 June 2017
Resolved
1430: The condition of the ship and its equipment shall be maintain to conform with the provision of he present regulations, whenever a defect is discovered the Master shall report at the earliest opportunity to the administration. A soft patch and pinhole leak were found on the S/W cooling line for the generator #1, 74 SOLAS (14 cons) , I/II, 40AC.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 28 June 2017
Resolved
2520: The company should ensure that any non-conformity is reported, appropriate action is taken and records of these activities is maintained. The SMS should ensure hazardous situations re reports to the company. The crew is using unsafe procedures to test the smoke detector over the main engine. The heat detector in the E/R workshop has an incorrect smoke detector label near it. See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 28 June 2017
Resolved
2550: Whenever a defect is discovered which affects the safety of the ship the Master shall report to the administration. A 4cm crack and a 6 cm crack were found on the steel plating of the door of the incinerator, 74 SOLAS (14 cons), I/11, 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2017
Resolved 29 June 2017
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.