MAURY USCG vessel records Sign in
← All vessels

PATRIOT

PATRIOT is a 2002 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2002, most recently in April 2026, along with 45 deficiencies and 2 operational controls.

Records from 2002 to 2026. Most recent: inspection, 24 April 2026.

Built
2002
Last inspected
24 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG7628
565351
Flag
UNITED STATES
367569180, 368463890
Maury page id
psix-565351

Inspections, by type

…with no type recorded1
Years with a record 19 calendar years (2002–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOAT BUILDING INC · ALBANY, NY, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ8629MMSI 368463890 · active · compulsorily equipped · granted 26 March 2026, expires 26 March 2036
WDG7628MMSI 367569180 · active · compulsorily equipped · granted 12 January 2023, expires 5 April 2033
WDF8222MMSI 367492650 · expired · compulsorily equipped · granted 28 May 2011, cancelled 31 July 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDB3451MMSI 366887250 · expired · compulsorily equipped · granted 2 April 2003, cancelled 18 May 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 28

24 April 2026 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8353056
17 June 2025 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8160070
5 September 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7996917
6 September 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7781216
31 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7660503
31 August 2022 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7548263
18 May 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7199877
16 June 2020 DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6978364
11 June 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6973785
16 July 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6752120
11 July 2018 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6473995
21 March 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373164
10 July 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6190947
20 April 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5858263
9 April 2009 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3853486
22 July 2008 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3271947
28 February 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3155577
10 July 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3023386
14 June 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2679512
13 February 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2584159
24 May 2005 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2366660
22 July 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2145374
28 June 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2112803
14 May 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2064063
25 June 2003 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1752917
28 May 2002 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1625407
19 May 2002 Initial Certification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1618335
14 May 2002 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1616542

Deficiency record · 45

05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 September 2023 Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. The technician conducting the inspection and providing the certification must not be the vessel's owner, operator, master, or employee or their affiliates. Radiotelephony certificate on board expired 01AUG2023.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 14 September 2023
Resolution: O/O provided photo copy of new radiotelelphony cert following technician's exam on 11SEP2023.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Aspirin in the first aid kit was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 14 September 2023
Resolution: O/O provided photo evidence of newly purchased aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2023 Resolved
At least one ring life buoy must be fitted with a lifeline. Ring buoy lifeline was fully parted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 September 2023
Resolved 6 September 2023
Resolution: O/O replaced and re-attached a new lifeline during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placard was posted in the bathroom, not adjacent to life jacket stowage locations; O/O relocated donning placard during inspection to an appropriate bulkhead near forward life jacket stowage location.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 September 2023
Resolved 6 September 2023
Resolution: O/O relocated life jacket donning placard to STBD side outboard bulkhead of the wheelhouse (near the life jackets stowed above).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020 Resolved
Vessel's waterlight on the life ring buoy had an expired battery (02/2020). Vessel restricted to daytime operations until corrected. 46CFR180.70(d).
Action required: 705 - Other - as specified
Resolved 29 June 2020
Resolution: Battery replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 June 2020 Resolved
Vessel COI expired 02JUN20. Make vessel available for and undergo a COI inspection prior to the carriage of passengers. 46 CFR 176.404
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2020
Resolution: Completed COI Renewal exam.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 July 2018 Resolved
Identified VHF DSC not receiving GPS position information. Conntect GPS to DSC. 47 CFR 80.905(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 8 August 2018
Resolution: Attended vessel and verified GPS position information in VHF-DSC
Engineering › Thrusters › Piping
Issued 10 July 2017 Resolved
Provide supports for bow thruster cables in forward compartment. 46CFR183.340(b)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 July 2017
Resolution: Supports installed.
Electrical › Lighting (service) › Conductor
Issued 10 July 2017 Resolved
Place wiring for engineroom lights conductor connections in junction box. 46CFR183.340(g)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 July 2017
Resolution: Two junction boxes installed.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 July 2017 Resolved
Close hole in starboard side engineroom compartment bulkhead. 46CFR176.800(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 July 2017
Resolution: Hole closed on engineroom exterior with wood/ interior with foam.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 April 2016 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 2 June 2016
Resolution: Instructions are posted.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 April 2016 Resolved
Light is inoperable.
Due 27 April 2016
Resolved 2 June 2016
Resolution: Light has been repaired, loose wiring.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2016 Resolved
Anchor light is inoperable.
Due 27 April 2016
Resolved 2 June 2016
Resolution: Light has been replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 April 2016 Resolved
Life ring buoyant line is worn around the ring.
Due 27 April 2016
Resolved 2 June 2016
Resolution: 2 ft of line has been cut back and ring now has 80+ feet of good line.
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 April 2016 Resolved
Post lifejacket donning placard.
Due 27 April 2016
Resolved 2 June 2016
Resolution: Placard has been placed in view of passengers.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 April 2016 Resolved
Properly lable lifejacket stowage.
Due 27 April 2016
Resolved 2 June 2016
Resolution: Stowage has been properly labled.
Engineering › Bilge Water Management System › Pump
Issued 20 April 2016 Resolved
Electrical bilge pump indicator light is inoperable.
Due 27 April 2016
Resolved 2 June 2016
Resolution: Replaced faulty wiring.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 20 April 2016 Resolved
Vent shows signs of leakage due to over fill.
Due 27 April 2016
Resolved 2 June 2016
Resolution: Vent has been disassymbled and resealed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 April 2009 Resolved
Owner notified unit that vessel was no longer being used as an inspected passenger vessel. The issued/effective COI, and CG-5256 were removed from the vessel this date. Vessel will be required to undergo a Hull/ISE, and a Renewal of COI exam prior to carrying passengers. De-activated COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2011
Resolution: COD issued on FEB 03, 2011 New name, Owner, to expire on FEB 29, 2012
Construction/Loadline › Penetrations › Valve Flange
Issued 28 February 2008 Resolved
Shut off valve for the submersible electric bilge pump was located in line 4' from thru hull. Relocate valve to hull fitting.
Due 14 March 2008
Resolved 13 March 2008
Lifesaving › Hand Flares › Quantity
Issued 10 July 2007 Resolved
Provide required number of flares for LBS route (3/3). 46CFR180.68
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 9 August 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 July 2007 Resolved
Service all fire appliances, which expired on (5-22-07). 46CFR176
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 9 August 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 July 2007 Resolved
Provide a fuel shutoff at or as near the engine as possible. 46CFR182
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 9 August 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 June 2004 Resolved
Provide an electric floating light approved under 46 CFR 161.010 for life ring buoy as required by 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2004
Resolved 28 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 June 2004 Resolved
Provide 1 Adult Type I PFDs approved under 46 CFR 160.055.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2004
Resolved 28 June 2004
Engineering › Fuel Oil Service System › Valve
Issued 27 June 2004 Resolved
Mark propulsion engine fuel oil shut off valve in accordance with 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 22 July 2004
Engineering › Bilge Water Management System › Valve
Issued 27 June 2004 Resolved
Install positive shut off device in electrical submersible bilge pump overboard discharge as close to hull penetration as practicable in accordance with 46 CFR 182.520(e)(7).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 27 June 2004 Resolved
Terminate bus bar connections for electric submersible pump to suitable enclosure in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 22 July 2004
Operations/Management › Drills/Instruction
Issued 19 May 2002 Resolved
Conduct fire and abandon ship drills to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Crew conducted satisfactory drills.
Operations/Management › Drug and Alcohol Testing
Issued 19 May 2002 Resolved
Provide proof of drug and alcohol testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Owner provided proof of enrollment into ASAP consortium.
Operations/Management › Vessel Safety Management
Issued 19 May 2002 Resolved
Provide emergency instruction list.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Owner provided emergency instruction list.
Personnel › Certificates/Documents/Licenses
Issued 19 May 2002 Resolved
Provide valid operators license for route and service. LEGACY COMPONENT DESC: License, Master
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Owner provided valid operators license.
Communications › Internal Communications System
Issued 19 May 2002 Resolved
Provide fixed means of communication between Pilothouse and engineroom. Portable radio would be sufficient for this use. LEGACY COMPONENT DESC: Portable Radios
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 25 June 2003
Resolution: Owner provided fixed means of communication.
Documentation › Certificates/Documents
Issued 19 May 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 1 July 2002
Resolved 28 May 2002
Resolution: Owner provided FCC Station license and Safety certificate.
Communications › Radio Communications
Issued 19 May 2002 Resolved
Provide emergency broadcast placard.
Action required: 705 - Other - as specified
Due 1 July 2002
Resolved 28 May 2002
Resolution: Owner provided emergency broadcast placard.
Navigation › Piloting/Steering
Issued 19 May 2002 Resolved
Provide up to date charts, tide & current tables, light list and coast pilot for area of operations. LEGACY COMPONENT DESC: Marine Charts
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Owner provided current charts, tides and current tables, light list and coast pilot for area of operation.
Stability › Watertight Integrity
Issued 19 May 2002 Resolved
Properly mark forward watertright hatch, "watertight hatch keep closed"
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Owner properly marked fwd watertight hatch.
Operations/Management › Navigation Safety
Issued 19 May 2002 Resolved
Complete satisfactory new to zone inspection with local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2002
Resolved 28 May 2002
Resolution: Owner completed new to zone inspection with local OCMI.
Electrical › Electrical Distribution System (service)
Issued 14 May 2002 Resolved
Ensure the Main Battery Switches are rated according to the amperage of the system. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: MBS are rated to amperage of system
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 14 May 2002 Resolved
Conduct As Built Verification of the Fixed Fire Fighting system
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: Conducted satisfactory as built verification of FFE
Engineering › Bilge Water Management System
Issued 14 May 2002 Resolved
Bilge pump and piping must meet the requirements of 46 CFR 182.520(e)(f). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: Bilge pump and piping meet 46 CFR 182.520
Engineering › Fuel Oil Storage/Transfer System
Issued 14 May 2002 Resolved
Fuel Tank fill, sounding, and ventilation piping shall be properly grounded to the hull in accordance with 46 CFR 182.445(g) LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: Found satisfactorily grounded
Engineering › Fuel Oil Service System
Issued 14 May 2002 Resolved
Fuel line remote shut-off valves shall be installed and located in accordance with 46 CFR 182.720. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: Found satisfactory
Engineering
Issued 14 May 2002 Resolved
All nonmetallic piping materials for vital systems shall be in accordance with 46 CFR 182.720. LEGACY COMPONENT DESC: Nonmetallic Piping
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: Nonmetaqllic piping standards found satisfactory
Accommodation/Occupational Safety › Ventilation
Issued 14 May 2002 Resolved
Ventilation of the Diesel Tank space is subject to the approval of the attending USCG marine Inspector. LEGACY COMPONENT DESC: Diesel Tank Space
Action required: 705 - Other - as specified
Due 6 June 2002
Resolved 19 May 2002
Resolution: Ventilation of fuel tank space found satisfactory

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.