MAURY USCG vessel records
← All vessels

MATTERHORN TLP

Built
2003
Last inspected
28 February 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 February 2025
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

565761
Flag
UNITED STATES
Maury page id
psix-565761

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

28 February 2025 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8088518
14 June 2024 COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7941788
8 February 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7878480
7 December 2022 Administrative Inspection · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7629097
21 June 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482843
2 February 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7389434
6 January 2022 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7376872
17 May 2021 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7199989
22 September 2020 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7062898
6 March 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6923194
30 July 2019 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6784585
22 April 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6669181
25 October 2018 COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6568256
13 November 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6306633
17 November 2016 Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6081838
1 September 2016 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6054234

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 December 2022 No resolution recorded
Each space protected by a fixed gaseous fire supression system must have doors for each opening. All doors at e-gen enclosure not fitting tightly or closing with large gaps. 46CFR108.455(c)(1)
Due 1 June 2023 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2022 Resolved
All Auxiliary engines installations shall be suitable for intended service. Emergency generator found with a substantial exhaust leak at the turbo and stack.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 2 February 2022
Resolution: Received confirmation exhaust leak was reparied.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 May 2021 Resolved
IAW 33CFR146.15 all emergency equipment must be maintained in good condition. During a review of the third-party service records, the facility's annual service report (dated May 2020) for lifesaving appliances noted deficiencies listed in annual narrative summary. CG/BSEE Inspectors observed defs had not been corrected and lifeboats remained in service. As a result, the CG cannot verify that the lifeboats have been maintained in good condition and are readily available for emergency evacuation as noted in the EEP. Therefore, the fac must reduce the crew compliment to (1) OIM, (2) BCO, (2) AB, and (1) OS, and no additional POB. 33 CFR 146.15 / 46 CFR 108.515 / 46 CFR 108.525 66 c
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Due 17 May 2021
Resolved 29 May 2021
Resolution: CG observed third-party completed annual servicing and annual reviewed report of lifeboats . The lifeboats noted deficiencies from annual service dated May 2020, were rectified. The lifeboats observed operational for means of evacuation.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 May 2021 Resolved
Within 48 hours the Operator must provide an amendment to their EEP for CG approval that addresses how the facility will meet the primary lifesaving requirements of 46 CFR 108.515 and 46 CFR 108.525 for those crew members remaining on board. No additional personnel are permitted on board without approval of the Coast Guard. In order to rectify this deficiency the Operator must provide documentation that all deficiencies noted in the May 2020 servicing report for lifesaving appliances have been corrected. 33 CFR 146.140 66 c
Action required: 66 - Prior to drilling or production operations
Due 17 May 2021
Resolved 27 May 2021
Resolution: Amendments to EEP were received and approved.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 May 2021 Resolved
IAW 33 CFR 146.125(c)(1) as further clarified by D8 OCS PL 01-20, all lifeboats on board a Manned Facility must be launched annually. In the course of the inspection the CG observed that no lifeboats had been launched within the previous 12 months. Prior to returning the lifeboats to service the Operator must ensure that an emergency evacuation drill has been successfully completed for each lifeboat. 33CFR 146.125(c)(1) 66 c
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Due 17 May 2021
Resolved 27 May 2021
Resolution: Witness satisifactory fire and abandon ship drill.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 17 May 2021 Resolved
IAW 33CFR143.120 each Floating OCS Facility must meet the requirements of 46CFR108.301 and act IAW their approved Stability Letter. During an evaluation of compliance with stability protocols in the MOM and on board operations, CG and BSEE Inspectors observed anomalies and warning alerts displayed on the Weight Report and TTMS Diagnostic portion of the facility's IMMS. As noted in the approved MOM, the system assists the Operator with maintaining stability of the facility. An open Condition of Class dated 31Oct2019 (see MISLE narrative). Currently, only 3 out of 36 load cells are active, but those 3 are unreliable due to phasing in and out of service. Currently the facility's COI requires 02 BCOs, which can be reduced to 01 BCO if ballast control operations do not exceed 12 hrs in a 24 hr period. Due to the current state of the TTMS, 02 dedicated BCOs are required to maintain the stability of the facility. Prior to reducing the required BCO compliment, the Operator must provide documentation demonstrating compliance with the stability letter. 33CFR143.120 / 46 CFR 107.305(ii) / 46 CFR 109.121 66 a/c
Action required: 66 - Prior to drilling or production operations
Resolved 29 August 2023
Resolution: Uploaded ABS survey and installer report attesting system is 100%
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2021 Resolved
IAW 33 CFR 146.15 all emergency equipment must be maintained in good condition. While performing a review of the third party service records, the facility's service report (dated July 2020) for firefighting appliances notes that the foam concentrate stored at fire station #32 and #34 failed its sample analysis. CG and BSEE inspector observed that this deficiency has not been rectified and the foam concentrate remains in service. Replace foam concentrate at stations #32 and #34 prior to resuming production operations. 33 CFR 146.15 66 c
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Due 17 May 2021
Resolved 27 May 2021
Resolution: Verified documentation and installation of new AFFF at fire station #32 and 34.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 6 March 2020 Resolved
The emergency equipment provided, regardless of whether or not required by this sub-chapter, shall be maintained in good condition at all times. Found saturation in canopy of lifeboat #1. Provide "A" weight. May be approved by third party report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2020
Resolved 28 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 March 2020 Resolved
The emergency equipment provided, regardless of whether or not required by this subchapter, shall be maintained in good condition at all times. Found maintenance schedule for releasing gear not IAW manufacturer's manual. Require proof maintenance is being completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2020
Resolved 28 April 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 March 2020 Resolved
Found two members did not have medical certificates onboard. Provide proof of certificates and provide BCO due to TTMS unreliability.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2020
Resolved 28 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2019 Resolved
Turbine "A" generator out of service due to low PCD and High T5 alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 23 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2019 Resolved
Tendon Tension Monitoring System (TTMS) is currently operating with tendons T1, T5 and T6 being manually calculated due to failed readings from the tendon load cells. Additionally, tendon 5 is completely failed with bridge 2 failure and no acceptable values on T5,B1. Estimated health of the TTMS is approximately 40% and is not operating within acceptable limits to provide validation of weight maintenance and monitoring per the approved Marine Operations Manual (MOM) and unit stability letter. Until TTMS is restored, unit is prohibited from skidding on a drilling unit.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 17 May 2019
Resolution: Provide a written submittal of mitigation plan along with time line to restore TTMS redundancy within 1 month.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 October 2018 Resolved
Multiple nozzles on deluge system were inoperable in area protecting equipment in well bay.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 12 November 2018
Resolution: Equipment replaced and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 October 2018 Resolved
Prove LB #1 also meets the requirement of a rescue boat. Provide Certificate of Approval for the boat stating it was also prototype tested as a RB and update the data plate to include 46CFR 160.156 if it meets the requirements. 46CFR 160.560 and 46CFR 160.156-17. 50 c.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 12 November 2018
Resolution: Paperwork and data plate provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 October 2018 Resolved
Prove LB #1 also meets the requirement of a rescue boat. Provide Certificate of Approval for the boat stating it was also prototype tested as a RB and update the data plate to include 46CFR 160.156 if it meets the requirements. 46CFR 160.560 and 46CFR 160.156-17. 50 c.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2018
Resolved 12 November 2018
Resolution: Palfinger came out and did maintenance on brake.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 October 2018 Resolved
All davits were missing CG approval on data plates. Obtain data plates from manufacturer with CG approval numbers onboard. 46CFR 160.132-17. 50 c.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 20 November 2018
Lifesaving › Launching Appliances › Winch
Issued 1 September 2016 Resolved
Lifeboat winch on Lifeboat #1 does not meet required recovery rate as tested by inspector, winch must meet recovery rate for rescue boat
Due 1 October 2016
Resolved 30 September 2016
Resolution: Barge Supervisor provided e-mail and notes from 3rd party attesting to winch repairs to meet recovery speed
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 September 2016 Resolved
Several A-class fire doors (noted on separate list recorded by crew) did not properly close and latch.
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 30 September 2016
Resolution: Barge Supervisor submitted e-mail attesting to repaired fire doors on list from inspectors.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.