Records from 2016 to 2026. Most recent: inspection, 22 May 2026.
Inspection history · 25
22 May 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8378596
19 February 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8312812
27 October 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8260936
24 April 2025
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8120199
6 March 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8089513
24 April 2024
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7901384
31 July 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7758007
30 August 2022
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7547959
21 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482824
17 November 2020
In-Service Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7097663
22 January 2020
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6907862
1 November 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6870529
10 October 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6832047
4 January 2019
Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6604232
30 April 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6558598
14 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6325085
20 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6310339
16 October 2017
Construction Oversight
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6349541
24 July 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6227275
13 October 2016
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6024304
28 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6011711
19 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5977466
20 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913042
16 April 2016
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5855476
28 January 2016
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5807339
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 January 2019
Resolved
Sound signal device located on the facility's NW corner could not be heard within the required 2 mile radius, as noted on site by M/V Polaris (1244998). M/V Polaris at the request of CG Inspector moved 2 miles away from the platform's SE corner and were unable to hear proper operation of a sound signal device being projected from the facility. Device should audible in 360-degree Arc. Provide documentation attesting to proper operation of sound signal device.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2019
Resolved 10 October 2019
Resolution: Received email clearing outstanding deficiency.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 14 December 2017
Resolved
Each lifeboat must be a fire protected lifeboat protected under 46 CFR 160.135 with a self contained air system capable of providing air at a constant pressure for 10 mnutes. Air regulators appear to be malfunctioning or improperly set.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 15 December 2017
Resolution: OIM provided statement that the regulator was replaced and tested satisfactorly.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 28 January 2016
Resolved
There must be a means to close each vent. Two dampers failed to close. Repair ventilation closures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 29 January 2016
Resolution: Received email verification of repair. ABS was on scene to observe proper operation.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 28 January 2016
Resolved
Emergency equipment shall be maintained in good condition at all times. Air hose leaked in #2 lifeboat. Replace air hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 21 July 2016
Resolution: Spoke w/ Anadarko reg compliance manager, [name withheld], and got confirmation on replacement of air hose. No note or info left by departed previous lead MI.