A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 64
6 April 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8347072
11 August 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8207647
24 July 2025
Plan Review (Other than "T")
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8193488
26 February 2025
MTSA Verification · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8085508
25 February 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8084513
18 April 2024
MTSA Verification · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7903177
5 May 2023
Annual Inspection · MTSA Verification
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7685947
28 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7683683
4 March 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7674528
12 July 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7504658
11 March 2022
Administrative Inspection · Examination of Repairs
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7550536
7 February 2022
Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7569393
30 December 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7376599
12 October 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7386323
7 May 2021
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7193399
22 February 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7144444
19 February 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7142867
20 January 2021
Administrative Inspection · Plan Review (Other than "T")
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7128797
25 November 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7102001
21 October 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7081618
10 August 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7047341
3 August 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7023311
28 February 2020
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6920403
6 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6883194
16 October 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6835793
23 September 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6839574
12 August 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6780914
31 May 2019
Security Plan Review - VSP
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6993456
1 April 2019
Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6653914
28 January 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6616565
17 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6611834
17 January 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7120591
6 December 2018
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6593726
6 August 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6592155
22 July 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6487292
14 May 2018
USCG Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6414159
20 December 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6326973
26 October 2017
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6299197
6 July 2017
Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6219957
29 May 2017
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6159282
26 May 2017
Construction Oversight
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6156184
28 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6099385
17 October 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6023833
3 October 2016
MTSA Verification · Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6012931
25 August 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5982944
8 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5934081
15 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5776994
21 September 2015
Hull Examination · Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5214143
28 August 2015
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5228514
20 October 2014
MTSA Verification · Deficiency Check · Annual Inspection · In-Service Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5012670
16 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4118288
28 January 2010
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3716740
6 April 2009
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3480987
7 February 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3415586
7 April 2008
Hull Examination · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3335561
3 April 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3177043
11 March 2008
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3162244
12 January 2007
MTSA Verification · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2732807
24 July 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2723393
10 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2423986
15 April 2005
Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2429422
19 January 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2278561
20 September 2004
Construction Oversight
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2207068
28 January 2003
Construction Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2185858
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 January 2020
Resolved
During the five year required crane recertification inspection on the port and stbd forward cranes severe wasteage beyond the allowable acceptable limits was identified on multiple areas of both crane booms. The five year recertification testing was not able to be completed due to safety concerns.
Port and stbd cranes shall receive a satisfactory five year recertification (Load Test) in the presence of an attending marine inspector, ICGB or an authorized classification society prior to use.
OCMI will accept mitigation proposals with documentation to operate beyond the five year recertification (Load Test) with a satisfactory analysis reviewed and approved by a Professional Engineer for use until approved repairs are completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2020
Resolved 7 January 2020
Resolution: Rescinded and replaced with new item.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 January 2020
Resolved
During the five year testing on port fwd and stbd fwd cranes, significant corrosion was discovered along both booms. The depth, area, and location were documented and given to engineering for evaluation. The five year certification could not be completed due to safety concerns. The port fwd crane shall remain out of service until repairs are made and 5 year certification can be completed. Stbd fwd crane can only be used in emergencies when neither aft crane can reach, or for repair work on the fwd port crane. Upon completion and testing of port fwd crane, stbd fwd crane shall be tagged out until repairs are completed in accordance w/SEATRAX 5 year inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2020
Resolved 21 September 2020
Resolution: Satisfactorily tested and placed crane back into service after repairs.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 August 2006
Resolved
Repair replace bad A-bulkhead doors / frames as necessary.
Due 30 November 2006
Resolved 12 January 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 6 April 2005
Resolved
Demonstrate compliance with 46 CFR 111.105-33 for all electrical installations in hazardous locations to the satisfaction of attending USCG Marine Inspector prior to COI.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 January 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 April 2005
Resolved
Complete installation of platforms to reach controls on elevated motor controllers, switchboards, and other unreachable control panels throughout hull to the satisfaction of attending Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Stability › Intact Righting Energy › General
Issued 6 April 2005
Resolved
Demonstrate proper operation of all valve position indicators for all manual remote valve controls (hand pumps) to the satisfaction of USCG MI prior to COI. Until that time, maintain strict compliance with BP Proposal of April 1, 2005 WRT operation and replacement of all position indicators.
Action required: 705 - Other - as specified
Resolved 27 July 2006
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 April 2005
Resolved
Remove all machinery not associated with, or equipment not in support of the normal operation of the emergency power source and emergency switchboard from egen and EMCC spaces per 46 CFR 112.05-5(d) to the satisfaction of [name withheld] prior to COI.
Action required: 705 - Other - as specified
Resolved 29 June 2006
Fire Fighting › Fire Pumps › Pressure
Issued 6 April 2005
Resolved
Demonstrate that fire protection system for helicopter landing deck is capable of discharging from each hose at 100 psi prior to helicopter fueling operations.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Fire Fighting › Fire Pumps › Capacity
Issued 6 April 2005
Resolved
Demonstrate proper operation of all diesel driven fire pumps prior to operation and COI - to the satisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 16 May 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 6 April 2005
Resolved
Remove dead-ended piping and properly terminate cooler inlet and outlet seawater lines to fire pumps (presently crimped and welded). Requirement to be completed to the satisfaction of attending USCG Marine Inspector prior to fire pump operation and COI.
Action required: 705 - Other - as specified
Resolved 12 June 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 April 2005
Resolved
Provide safe egress routes over rails for traveling riser gantry crane. Temporary arrangements for "scaffold" stairs are acceptable for tow-out. Permanent arrangements (stairs) to be installed to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 6 April 2005
Resolved
Install stainless steel piping on INERGEN activation systems manifold or provide acceptable solution for interior pipe rust (corrosion) to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 18 May 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 September 2004
Resolved
Install A-0 doors in accordance with structural fire protection standards. Door catching mechanisms create a 3-square inch hole in door jam. Item to be completed to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 18 May 2006
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 20 September 2004
Resolved
Demonstrate proper operation of drill floor foam system to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 18 May 2006
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 20 September 2004
Resolved
Demonstrate proper operation of shale shaker space and mud pit foam system(s) to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 18 May 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 September 2004
Resolved
Demonstrate proper operation of column elevators, derrick elevators, and helideck luggage dumbwaiter as prescribed under 46 CFR 111.91. Requirement must be completed to the satisfaction of the American Bureau of Shipping (ABS) in accordance with NVIC 10-82 Change 2 prior to operation of these systems.
Action required: 705 - Other - as specified
Resolved 27 July 2006
Resolution: helideck dumb water to handled as a work list item.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 20 September 2004
Resolved
Provide toilet seats for all toilets with "open front" IAW 46 CFR 108.205(m) to the satisfaction of attending Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 September 2004
Resolved
Demonstrate man-overboard drill with fast rescue craft to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 1 June 2006
Engineering › Pressure Vessel › Marking and Stamping
Issued 20 September 2004
Resolved
Make all drilling system bulk tanks available for inspection and provide all information & access required by attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 28 June 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 September 2004
Resolved
Demonstrate compliance with 46 CFR 58.60 and 46 CFR 111.107 for all industrial systems to the satisfaction of attending USCG Marine Inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 12 January 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 20 September 2004
Resolved
Demonstrate proper operation of potable water system for modular accommodations - including reverse osmosis water maker - to the satisfaction of attending USCG Marine Inspector prior to habitation of these quarters.
Action required: 705 - Other - as specified
Resolved 20 September 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 September 2004
Resolved
Demonstrate proper operation of sewage system(s) for modular accommodations prior to habitation of these quarters.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 20 September 2004
Resolved
Obtain USCG approval of operating manual and construction portfolio prior to COI.
Action required: 705 - Other - as specified
Resolved 27 July 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 September 2004
Resolved
Obtain USCG approval of Emergency Evacuation Plan (EEP) IAW 33 CFR 146.140 prior to COI.
Action required: 705 - Other - as specified
Resolved 22 June 2006
Communications › Alarms/Indicators › General Alarm
Issued 20 September 2004
Resolved
Once offshore and operating all machinery/equipment, demonstrate that general emergency alarm signal produces minimum sound pressure levels above ambient noise levels required by 46 CFR 113.25-12 and 46 CFR 113.50-15 for public address system prior to COI.
Action required: 705 - Other - as specified
Resolved 12 January 2007
Resolution: see Act # 2732807