A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2026
Resolved
Provide 8 additional Type I adult life jackets so there is a total of at least 32 on board. Vessel is limited to carrying 22 total passengers and 24 total people.
Action required: 705 - Other - as specified
Resolved 5 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2026
Resolved
Place Type I retroreflective material (SOLAS tape) on 5 life jackets as identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2026
Resolved 5 August 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2026
Resolved
Provide a visual indicator for the aft automatic bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2026
Resolved 5 August 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2026
Resolved
The lens for the combination side navigation light is becoming opaque. Clean lens or install new so the light is visible up to 1 nm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2026
Resolved 5 August 2026
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 July 2026
Resolved
Provide an up to date copy of the U.S. Coast Pilot [name withheld] List, and Tide Tables for the vessel's operating area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2026
Resolved 5 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2025
Resolved
Provide and mark 3 additional adult Type I life jackets so there are a total of 32 on board. Vessel limited to carrying 27 passengers.
Action required: 705 - Other - as specified
Resolved 10 July 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 June 2025
Resolved
Drill logs have not been maintained. Drills were conducted during the inspection on 24 Jun 2025. Log drills with who was involved, date of drill, and a general description.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 10 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2025
Resolved
Provide current extracts of the U.S Coast Pilot [name withheld] List, and Tide Tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 10 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 June 2025
Resolved
Label life jacket storage locations with the type (adult or child) and quantity stored inside in letters and numbers at least 2" high.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 10 July 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 August 2024
Resolved
Identified 3 inch long crack in port bow approx. 3 feet above the waterline. Damage most likely caused by anchor impact. Grind back and renew.
Action required: 705 - Other - as specified
Resolved 29 August 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Install metal support hangers with chafing material on all wire runs in the engine compartment.
Action required: 705 - Other - as specified
Resolved 29 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 June 2024
Resolved
Mark each life jacket stowage location with the type (adult or child) and number of life jackets stowed inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 April 2023
Resolved
Conduct emergency fire, man overboard, and steering drills with a Captain and Deckhand normally filling those positions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2023
Resolved
Provide 05 additional adult life jackets so there are a total of 32 adult life jackets on board. Vessel restricted to carrying a maximum of 25 passengers.
Action required: 705 - Other - as specified
Resolved 7 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2023
Resolved
Provide a valid FCC Safety Radio Certificate prior to operating beyond 1,000 feet from shore.
Action required: 705 - Other - as specified
Resolved 7 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2023
Resolved
Attach a 3'-6'lanyard with a corrosion resistant clip to the ring life buoy's waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 April 2023
Resolved
Provide a visual indicator for the aft automatic submersible bilge pump or make pump manually operation only.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 April 2023
Resolved
Label all life jacket stowage locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2023
Resolved
Label fuel shutoff valve and direction of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023
Resolved
The stern light cable splice must be made within a proper enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023
Resolved
Remove the dead end wiring running underneath the port side benches.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2023
Resolved
Provide proof of random chemical testing (Consortium roster) for all crewmembers.
Action required: 10 - Deficiency Rectified
Resolved 4 April 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 June 2022
Resolved
The pre-engineered fixed gas fire extinguishing system does not automatically automatically shut down the engine. Prove that the system will automatically shut down the engine upon simulated activation and the systems reset device will allow the engine to start in override prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2022
Resolved
03 of 32 adult life jackets were not in serviceable condition. Vessel's passenger count reduced to 27 until 03 additional adult life jackets are purchased and placed on board.
Action required: 705 - Other - as specified
Resolved 12 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2022
Resolved
Properly mount fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2022
Resolved
Install a light to indicate when the aft electronic submersible bilge pump is running or make it capable of manual activation only.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 June 2022
Resolved
Log or otherwise document abandon ship, man overboard, and fire fighting training and drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 August 2021
Resolved
Address exhaust leak in engine compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 August 2021
Resolved
Make anchor light operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2021
Resolved
Connect discharge end of fixed hand bilge pump to through hull fitting.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2021
Resolved
02 adult life jackets were not in serviceable condition. Replace 02 adult life jackets to make a total of 32 adult life jackets prior to carrying more than 28 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 August 2021
Resolved
Replace expired medications in the first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 August 2021
Resolved
Log or otherwise document training for each crewmember at least once every three months as to the duties that crew member is expected to perform in the following emergencies: rough weather at sea, crossing hazardous bars, or flooding; man overboard; and fire fighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 August 2021
Resolved
Provide educational information as part of the company's required Employee Assistance Program. The educational information shall include the display and distribution of a community service hot-line telephone number for crewmembers seeking assistance with drug and alcohol abuse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 August 2021
Resolved
Provide and document training for all crewmembers as part of the company's required Employee Assistance Program. The training information shall include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment as well as the manifestations and behavioral cues that may indicate drug and alcohol use and abuse. Training for personnel in supervisory positions (Captains) must receive at least 60 minutes of training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 31 October 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2021
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for annual inspection. Anniversary date is 02APR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 11 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 October 2020
Resolved
Vessel failed to undergo an Annual Inspection within the 3 months before or after the COI anniversary date. 46 CFR 176.500 (b)(1) -Deficiency rectified
Action required: 10 - Deficiency Rectified
Resolved 23 October 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 October 2020
Resolved
Provide valid operator’s license prior to carrying passengers. 46 CFR 185.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 October 2020
Resolved
Provide valid Florida state registration. 33 CFR 173.15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2020
Resolved
Provide an adult life jacket for each person carried on board. The vessel’s COI states it can carry a maximum of 32 total people (30 passengers and 2 crew). There are only 23 total adult life jackets on board. Vessel may only carry 21 passengers until an additional 9 adult life jackets are provided. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 24 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 October 2020
Resolved
Provide a total of 6 hand red flare distress signals and 6 hand orange smoke distress signals as required for a limited coastwise route (or a total of 12 hand red flare distress signals approved in accordance with 46 CFR 160.021). 46 CFR 180.68 -Deficiency rectified
Action required: 10 - Deficiency Rectified
Resolved 23 October 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 October 2020
Resolved
Provide up to date (2020) versions of the U.S. Coast Pilot [name withheld] List and Tide Tables. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2020
Resolved
Replace hose in the closed fresh water cooling system. 46 CFR 182.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2020
Resolved
Make unused port fuel tank vapor tight. 46 CFR 182.440
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2020
Resolved
Replace the positive battery cable that has signs of previous heat damage. 46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 October 2020
Resolved
Provide 2 operable portable battery lights. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
Provide 2 portable lights, flashlights.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: 2 new flashlights
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2019
Resolved
Provide covers for terminals on batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: both batteries have covers straped down.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2019
Resolved
Provide current Certificate of Documentation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: COD on board vessel
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 May 2019
Resolved
Provide State registration for vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: State registration on board
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 May 2019
Resolved
Replace SOLAS tape on 01 life jacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: new life jacket purchased
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 May 2019
Resolved
Replace 100 aspirin in first aid kit, aspirin currently expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: aspirin replaced
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 May 2019
Resolved
Vessel log must be on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: Vessel log on board vessel.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 2 April 2019
Resolved
Submit plans for fuel tank replacement to local [name withheld] construction is complete conduct pressure test in the presence of Marine Inspector. Gas free port tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2019
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 April 2018
Resolved
Post sign for passengers that COI and Stability Letter is available upon request.
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 23 April 2018
Resolution: Posted sign.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 April 2018
Resolved
Provide proof of required drills in logbook.
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 23 April 2018
Resolution: Provided log of required drills and EPIRB tests.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 June 2017
Resolved
Provide SOLAS tape (retroreflective) on both sides of ring buoy.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 28 July 2017
Resolution: ring buoy corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2017
Resolved
Provide first aid kit IAW 160.041 (aspirin)
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 28 July 2017
Resolution: Aspirin was replaced, kit complete.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 June 2017
Resolved
Provide current FCC safety Certificate.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 28 July 2017
Resolution: Valid certificate provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 February 2017
Resolved
Fire extinguishers shall be serviced annually
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 February 2017
Resolved
At least one life ring must be fitted with a lifeline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 6 February 2017
Resolved
Provide a VHF radio with GPS input
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 10 March 2017
Resolution: Installed new radio with integrated GPS
Documentation › Certificates/Documents › Stability Letter
Issued 3 August 2016
Resolved
Post Stability Letter on vessel on vessel with all pages visible at the operating station
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 3 August 2016
Resolved
Post Emergency instruction at op station
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Engineering › Bilge Water Management System › Pump
Issued 3 August 2016
Resolved
Bilge Pumps need to be listed by Underwriters Laboratories Inc(UL 1113)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Documentation › Certificates/Documents › FCC SSL
Issued 3 August 2016
Resolved
Provide on board vessel the FCC Station License
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 August 2016
Resolved
Connections must be made to battery terminal with permanent type connections
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2016
Resolved
Renew battery in Ring Lifebuoy floating water-light
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 August 2016
Resolved
Provide all required items for First Aid Kit as listed within
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 15 February 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 August 2016
Resolved
Provide Indicating Light for required voids indicating Bilge Pump ops & high water alarms
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 3 August 2016
Resolved
Provide on board all Navigation Publications & charts for intended area of operation
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 August 2016
Resolved
Provides metal supports and protection for Engine Space Wiring every 24"
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 August 2016
Resolved
Provide valid Certificate of Documentation
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 August 2016
Resolved
Complete emergency drills to the satisfaction of the attending C. G. Marine Inspector
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Stability › Water on Deck › General
Issued 3 August 2016
Resolved
Provide 40 square inches of deck drainage to effectively clear water to bilges
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 3 August 2016
Resolved
Provided a means to close ventilation for engine room (space protected by fixed ff)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Lifesaving › Hand Flares › Quantity
Issued 3 August 2016
Resolved
Provide on board appropriate quantity of flares for intended area of operation
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 August 2016
Resolved
board portable bilge pump with sufficient length of hose to dewater spaces
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 3 August 2016
Resolved
Provide on board sufficient ground tackle satisfactory for size of vessel & area of ops
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 August 2016
Resolved
Cap/plug holes for old controls on front surface of operating station
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 August 2016
Resolved
Consult with the cognizant Officer in Charge Maine Inspections zone in which you intend to operate
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 August 2016
Resolved
Annual inspection of vessel completed to maintain vessel's COI. Vessel shall not operate in this or other zones until all requirements have been corrected to the satisfaction of the attending C. G. Marine Inspector
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 10 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 August 2016
Resolved
Child size PFD's must be stowed separate from adult PFDs with location appropriately marked
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Lifesaving › Lifebuoys › Not on Board
Issued 2 August 2016
Resolved
Provide on board 1 Orange Ring Lifebuoy 24" required for anticipated operation
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Engineering › Freshwater System (jacketwater cooling) › Filling Line
Issued 2 August 2016
Resolved
Properly install approved hose for water intake with two clamps on fitting
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 15 February 2017
Stability › Watertight Integrity › General
Issued 2 August 2016
Resolved
Replace wasted decking & make side voids watertight
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 6 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 May 2012
Resolved
Prior to carrying passengers, conduct U/W drills. Provide documentation of drills to MSD Peoria.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2012
Communications › Public Address System › Amplifier
Issued 30 May 2012
Resolved
Prove proper operation of the vessel P/A system.
Due 30 June 2012
Resolved 26 June 2012
Engineering › Bilge Water Management System › Pump
Issued 30 May 2012
Resolved
Prove proper operation of the forward void hand bilge pump.
Due 30 June 2012
Resolved 26 June 2012
Electrical › Electrical Distribution System (service) › Switch
Issued 30 May 2012
Resolved
Prove proper operation of the operator console starter switch.
Due 15 July 2012
Resolved 9 July 2012
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 May 2012
Resolved
Prove proof of Drug and Alcohol Program supervisory training.
Due 30 June 2012
Resolved 18 June 2012
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 30 July 2009
Resolved
USCG Documented vessel marked with State number.
Action required: 705 - Other - as specified
Due 1 June 2010
Resolved 5 June 2010
Engineering › Bilge Water Management System › Piping
Issued 12 May 2009
Resolved
Tighten the engineroom bilge piping discharge valve and connection.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: Connection tightened
Engineering › Bilge Water Management System › Not Operational
Issued 12 May 2009
Resolved
Ensure the aft auto bilge pump switch shuts off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2009
Resolved 22 September 2009
Resolution: Tested switch sat
Engineering › Bilge Water Management System › Piping
Issued 12 May 2009
Resolved
Properly secure the aft bilge pump and discharge hose.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: Pump and hose secured
Engineering › Bilge Water Management System › Vent
Issued 12 May 2009
Resolved
Clean all limber holes to ensure water can drain to the bilge pump.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: Bilges cleaned
Electrical › Electrical Distribution System (service) › Switch
Issued 12 May 2009
Resolved
Prove proper operation of the MDE starter switch.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: Stater switch tested and working properly
Electrical › Electrical Distribution System (service) › Busway
Issued 12 May 2009
Resolved
Determine source of the electrical ring.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Documentation › Markings/Placards › Warning Signs
Issued 12 May 2009
Resolved
Label all operation station console alarms and indicators.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2009
Resolved 22 September 2009
Resolution: Verified all alarms and indicators properly labeled
Engineering › Bilge Water Management System › Pump
Issued 12 May 2009
Resolved
Ensure the engineroom auto bilge pump operates properly and properly mount.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: bilge pump operational and securely mounted
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 12 May 2009
Resolved
Remove oil from the engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2009
Resolved 22 September 2009
Resolution: Bilges free of oil
Engineering › Bilge Water Management System › Piping
Issued 12 May 2009
Resolved
Properly install the high level bilge alarm and the bilge pump in aft void.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: Pump and alarm installed
Fire Fighting › Ventilation Systems › Ducts
Issued 12 May 2009
Resolved
Ensure the vent closures are fire retardant.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 12 May 2009
Resolved
Replace the high water temperature sensor on the MDE.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Resolution: renewed
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 12 May 2009
Resolved
Seal (make vapor tight) around the exhaust pipe bulkhead penetration.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Resolution: Fire stop material added to seal bulkhead.
Fire Fighting › Ventilation Systems › Ducts
Issued 12 May 2009
Resolved
Properly mount the engineroom natural supply vent duct pipe.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Engineering › Bilge Water Management System › Pump
Issued 12 May 2009
Resolved
Ensure the aft void auto bilge pump has an indicator light at the operating station.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Resolution: Indicator light added to console
Engineering › Bilge Water Management System › Pump
Issued 12 May 2009
Resolved
Properly mount the aft high level bilge alarms.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Engineering › Bilge Water Management System › Not Operational
Issued 12 May 2009
Resolved
Ensure the aft bilge pump operates in the manual mode.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 22 September 2009
Resolution: Witnessed auto mode test
Engineering › Bilge Water Management System › Pump
Issued 12 May 2009
Resolved
Install a high level bilge alarm in the forward void and ensure there is an indicator light and alarm at the operating station.
Due 1 September 2009
Resolved 22 September 2009
Resolution: High level alams and indicator light installed.
Engineering › Bilge Water Management System › Pump
Issued 12 May 2009
Resolved
Remove the old forward void, bilge pump.
Due 1 September 2009
Resolved 22 September 2009
Resolution: Pump removed.
Engineering › Bilge Water Management System › Valve
Issued 12 May 2009
Resolved
Install a through hull discharge valve for the forward bilge pump.
Due 9 July 2009
Resolved 30 June 2009
Resolution: An auto bilge pump was not installed (repaired the old installed manual hand pump) so their is no requirement to have the shut-off valve.
Electrical › Electrical Distribution System (service) › Switch
Issued 12 May 2009
Resolved
Ensure the MDE starter box is properly wired.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Electrical › Electric Generation Source (service) › Switch
Issued 12 May 2009
Resolved
Remove the old abandoned charging system.
Due 1 September 2009
Resolved 22 September 2009
Resolution: Charging system removed.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 12 May 2009
Resolved
Replace the MDE raw water forward rubber hose and ensure it is double hose clamped.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 22 September 2009
Stability › Unintentional Flooding › General
Issued 12 May 2009
Resolved
Install a rubber gasket (vapor tight) around the aft bulkhead shaft penetration.
Condition: Placed in Improper Service
Due 9 July 2009
Resolved 22 September 2009
Resolution: gasket material installed.
Operations/Management › Drills/Instruction › Fire
Issued 12 May 2009
Resolved
Properly mount the vessel safety instructions.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 12 May 2009
Resolved
Ensure the aft engineroom bulkhead in vapor/water tight.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 22 September 2009
Electrical › Electric Generation Source (service) › Panelboard
Issued 12 May 2009
Resolved
Repair or remove the operating station amp meter.
Due 1 September 2009
Resolved 22 September 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2009
Resolved
Install a smaller diameter line on the life ring float light.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 22 September 2009
Resolution: new line installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 May 2009
Resolved
Seal the stbd engineroom hatch cover vent and reattach the loose Velcro.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 22 September 2009
Engineering › Bilge Water Management System › Pump
Issued 12 May 2009
Resolved
Place back in-service or remove the forward void hand bilge pump.
Condition: Unknown
Due 30 June 2009
Resolved 30 June 2009
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 May 2009
Resolved
Provide a copy of your MIS report or proof of random testing.
Due 9 July 2009
Resolved 7 July 2009
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 12 May 2009
Resolved
Provide proof of enrollment in a consortium.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Resolution: Verified DAPI
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 12 May 2009
Resolved
Provide a chemical testing covered crew list.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 May 2009
Resolved
Repalce the two unservacable PFD's.
Due 1 September 2009
Resolved 22 September 2009
Resolution: Replaced with new.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2009
Resolved
Repair dead end wires in the forward void.
Condition: Unknown
Due 1 September 2009
Resolved 22 September 2009
Resolution: Dead end wires removed.
Lifesaving › Lifebuoys › Stowage
Issued 12 May 2009
Resolved
Ensure life ring is capable of being cast free.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 22 September 2009
Operations/Management › Drills/Instruction › Fire
Issued 12 May 2009
Resolved
Update the vessel NPS contact info.
Due 1 September 2009
Resolved 22 September 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2009
Resolved
Ensure first aid kit contains the required items.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 22 September 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 May 2009
Resolved
Properly secure the batteries and boxes.
Due 1 September 2009
Resolved 22 September 2009
Engineering › Bilge Water Management System › Pump
Issued 7 June 2008
Resolved
prove proper operation of the bilge alarms and pump in aft compt.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 May 2008
Resolved
Replace life buoy lifeline with correct line.
Condition: Unknown
Due 7 June 2008
Resolved 20 June 2008
Resolution: Replaced
Communications › Visual Communication › Warning Sign (radio room)
Issued 21 May 2008
Resolved
Provide emergency broadcast placard.
Due 31 May 2008
Resolved 7 June 2008
Resolution: Provided.
Communications › Visual Communication › Warning Sign (gangway)
Issued 21 May 2008
Resolved
Provide/post emergency instructions
Due 31 May 2008
Resolved 7 June 2008
Resolution: Provded.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 21 May 2008
Resolved
Prove properation operation of staring system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2008
Resolution: Proved proper operation.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 21 May 2008
Resolved
pPove proper operation of fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2008
Resolution: Proved.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 May 2008
Resolved
Provide proof of updated Certificate of Documentation indicating new owner (must have coastwise endorsement). 46 CFR 67
Condition: Unknown
Due 13 July 2008
Resolved 31 May 2008
Resolution: provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 May 2008
Resolved
Provide proof of new operator's enrollment in a drug testing program meeting 46 CFR Part 16.
Condition: Unknown
Due 13 July 2008
Resolved 7 June 2008
Resolution: provided
Operations/Management › Drills/Instruction › Fire
Issued 13 May 2008
Resolved
Demonstrate fire and man overboard drills in the presence of an attending CG marine inspector. 46 CFR 185.520/.524
Condition: Unknown
Due 13 July 2008
Resolved 7 June 2008
Resolution: Completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 May 2008
Resolved
Prove proper operation of the main diesel propulsion engine, including controls and gauges to the satisfaction of the attending CG marine inspector. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2008
Resolved 19 June 2008
Resolution: Completed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 13 May 2008
Resolved
Prove proper operation of the automatic shut down (and over ride function) associated with the discharge of the fireboy fixed fire extinguisher in the engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2008
Resolved 19 June 2008
Resolution: Completed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 October 2006
Resolved
Prove proper operation of the automatic shut-down of main diesel engine upon discharge of fixed fire extinguisher (fireboy). 46 CFR 181.410/.420
Vessel may not carry passengers until this item has been cleared.
Due 11 November 2006
Resolved 13 May 2008
Resolution: Cleared and re-issued. Vessel is being sold and relocating to Wyoming.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 October 2006
Resolved
Provide copy of valid certificate of documentation with coastwise endorsement. 46 CFR 67
Due 11 November 2006
Resolved 13 May 2008
Resolution: Cleared and re-issued. Vessel is being sold and is relocating to Wyoming.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 October 2006
Resolved
Prove proper operation of ring buoy float light. 46 CFR 182.70
Vessel is restricted to day light operations until this item is cleared.
Due 11 November 2006
Resolved 13 May 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 July 2005
Resolved
Have vessel get underway and prove proper operation of the main diesel propulsion engine and throttle. Engine hunts/surges above 1500 rpm, stalls at slower speeds and is difficult to start. Have diesel tech report documenting condition found and repairs made.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2005
Resolved 21 July 2005
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 July 2005
Resolved
Install manual activation cable/pull assy on installed pre-engineered Fireboy extinguisher. Should be installed in close proximity to operating station, to the satisfaction of attending marine inspector. Vessel may not carry passengers until corrected.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2005
Resolved 21 July 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 July 2005
Resolved
Provide and post emergency instructions applicable to the intended area of operation to the satisfaction of the attending marine inspector. 46 CFR 185.512
Condition: Unknown
Due 22 July 2005
Resolved 21 July 2005
Electrical › Electrical Distribution System (service) › Fuse
Issued 15 July 2005
Resolved
Provide an in-line fuse of proper amp rating on the positive lead (as close to the battery as possible) for the Rule 4000 automatic bilge pump in the fwd bilge. 46 cfr 183.350
Condition: Improper Installation
Due 15 August 2005
Resolved 21 July 2005