Inspection history · 16
13 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8340482
18 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8094838
10 May 2024
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7916493
28 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7778326
10 April 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7668770
20 May 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7455566
27 January 2022
Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7387321
13 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7255241
11 May 2021
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7206600
9 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7206563
20 August 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6789562
7 May 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6679038
18 June 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6448455
28 April 2017
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6134712
20 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6129598
20 June 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5913600
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 May 2024
Resolved
Bilge overboard missing backing nut. Ovbd was glued in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 22 May 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 May 2024
No resolution recorded
Electric Bilge Pumps missing ovbd vlv
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2024
Resolved
Needs to be re-stenciled
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 22 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2024
Resolved
Remove breaker from the thruster battery box and place in a proper enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 22 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2024
Resolved
Rewire thruster as designed/appv'd.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 22 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 August 2023
Resolved
Each life float must be fitted with a light. 02 life floats had lights that were not attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
Resolution: Lights were attached to life floats.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 April 2023
Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Collision bulkhead was rotted at top in way of hatch. Repair prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 22 May 2023
Resolution: Observed satisfactory repair to bulkhead.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 May 2022
Resolved
Radio not installed during the inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2022
Resolved 28 May 2022
Resolution: VHF Marine Radio with DSC professionaly installed and tested.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 May 2022
Resolved
Charts worn and outdated
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 28 May 2022
Resolution: new charts provided
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 May 2022
Resolved
EPIRB Registration expired. Owner registered EPIRB with the FCC during the inspection.
Action required: 10 - Deficiency Rectified
Due 26 May 2022
Resolved 26 May 2022
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 May 2022
Resolved
EPIRB Hydrostatic Release improperly placed into service. Unable to verify installation date and EPIRB expiration led MI to beleive it was past its service life. New hydrostatic release provided during inspection.
Action required: 10 - Deficiency Rectified
Due 26 May 2022
Resolved 26 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 May 2022
Resolved
Lifefloats needed maintenance (owner stated replacing 2022). Unable to verify approval label, Verify proper batteries installed/replaced, replace individual pendants that connect to painter line (worn and short), replace retro-reflective tape (worn, not reflective), unable to verify weak link approval, relabel name and number of persons.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2022
Resolved 28 May 2022
Resolution: replaced worn materials with new and survival equipment properly installed. Lifefloats themselves and the older [name withheld] brand water lights recommended for replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2022
Resolved
missing 02 child lifejackets per labeled stowage compartment. Change label or provide 02 additional child lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 28 May 2022
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 May 2022
Resolved
Means of securing engine room ventilation from portside, main deck, missing the vent cover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2022
Resolved 28 May 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2022
Resolved
Provide manual for Pre-Engineered Fire extinguishing system
Action required: 10 - Deficiency Rectified
Due 26 May 2022
Resolved 26 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 May 2022
Resolved
Expired flares stowed in same location as the unexpired. Remove expired flares or stow in an alternate location away from ready supply.
Action required: 10 - Deficiency Rectified
Due 26 May 2022
Resolved 26 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2022
Resolved
Verify proper instalation of new Fin Stabilizer system. Vessel not to use this piece of machinery until cleared by Coast Guard Marine inspector.
Action required: 705 - Other - as specified
Due 26 May 2022
Resolved 14 July 2022
Resolution: Operationally Tested system. all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 May 2022
Resolved
COI expired on 23MAY2022.
46CFR176.100(a): A vessel to which this subchapter applies (T) may not be operated without having on board a valid US Coast Guard Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2022
Resolved 28 May 2022
Resolution: new COI Issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2021
Resolved
A submersible electric bilge pump may be used as a power
bilge pump provided that a positive shutoff valve is installed at the hull penetration.
On KYLIE'S CHANCE, several submersible electric bilge pump discharge lines are installed with no positive shutoff valve at the hull penetration. CORRECT PRIOR TO NEXT ANNUAL INSPECTION.
Action required: 705 - Other - as specified
Resolved 8 September 2023
Resolution: Item carried forward to next drydocking.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 August 2019
Resolved
bilge alarm in lazzarette inop
Due 10 September 2019
Resolved 10 September 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 August 2019
Resolved
bilge alarm in engine room inop
Due 10 September 2019
Resolved 10 September 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 August 2019
Resolved
current COI not posted
Due 10 September 2019
Resolved 10 September 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 June 2018
Resolved
Station License expired
Due 31 July 2018
Resolved 31 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 June 2018
Resolved
Vessel name not labelled
Due 31 July 2018
Resolved 31 July 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2018
Resolved
High bilge alarm light for lazzarrette inoperative.
Due 31 July 2018
Resolved 31 July 2018
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 26 May 2017
Resolved
Prove proper operation
Due 7 June 2017
Resolved 7 June 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 May 2017
Resolved
Provide current logs
Due 7 June 2017
Resolved 12 June 2017
Communications › Radio Communications › EPIRB
Issued 26 May 2017
Resolved
Provide current registration
Due 7 June 2017
Resolved 7 June 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 May 2017
Resolved
Provide current certificate
Due 7 June 2017
Resolved 7 June 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 May 2017
Resolved
Provide support for MSD macerator pump wiring
Due 7 June 2017
Resolved 7 June 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 May 2017
Resolved
Vessel COI expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2017
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 28 July 2016
Resolved
Provide means to read rpm and temperature
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2016
Resolved 7 June 2017
Navigation › Piloting/Steering › Marine Charts
Issued 21 June 2016
Resolved
Provide current charts LNM, Light List, Charts
Due 1 July 2016
Resolved 7 July 2016
Documentation › Certificates/Documents › FCC SSL
Issued 21 June 2016
Resolved
Not on vessel
Due 1 July 2016
Resolved 12 August 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 June 2016
Resolved
Not on board
Due 1 July 2016
Resolved 13 September 2016
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 21 June 2016
Resolved
Provide Marine Radio Operators Permit
Due 8 July 2016
Resolved 12 August 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 June 2016
Resolved
Provide new/proper batteries
Due 1 July 2016
Resolved 21 June 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 June 2016
Resolved
Provide copy of servicing report
Due 1 July 2016
Resolved 21 June 2016
Communications › Radio Communications › EPIRB
Issued 21 June 2016
Resolved
Provide current registration
Due 1 July 2016
Resolved 1 July 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 21 June 2016
Resolved
Connect VHF to GPS
Due 8 July 2016
Resolved 12 August 2016