Records from 2002 to 2016. Most recent: inspection, 16 May 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
16 May 2016
PII Safety Exam · Administrative Inspection · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5871110
20 March 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4819918
21 February 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4248223
17 February 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3676953
11 July 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3256493
21 February 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3151428
19 February 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3149986
9 December 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3112274
7 November 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3094861
25 July 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3007558
20 July 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3001556
23 June 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2970589
20 June 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2969286
12 September 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2491764
8 August 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2455819
8 August 2004
Ballast Water Examination · PII Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2159598
3 August 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2155011
9 May 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2062788
15 February 2004
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2007240
10 June 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1813945
8 June 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1812227
26 December 2002
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1723147
12 May 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1615872
11 May 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1615672
Engineering › Fuel Oil Service System › Pump
Issued 16 May 2016
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilizationof the oil fuel shall be such as to ensure the safety of the ship and persons on board. Fuel oil leak present on the fuel oil circulating pump shaft seal-74 SOLAS 01 cons. II-2/15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2016
Resolution: Classification society approved of the repairs to rectify the deficiency.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 16 May 2016
Resolved
lube oil leaks on generator and main engine lube oil purifier pumpshaft seals; lube oil leak on main engine turbo charger heat exchanger-74 SOLAS 01 cons. II-2/15.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2016
Resolution: Class society approved of the repairs to rectify the deficiency.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 16 May 2016
Resolved
Steam valve inlet for main engine jacket water heater leaking-74 SOLAS 01 cons. II-1/33.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2016
Resolution: Class society approved of repair to rectify the deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 May 2016
Resolved
02 soft patches found on oily-water separator overboard piping-74 SOLAS 14 cons. I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2016
Resolution: Class society approved of the repairs to rectify the deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 May 2016
Resolved
Sample line to the Oil Content Meter was found clogged, not allowing OCM to read proper discharge effluent dilution.MARPOL Annex 1 14.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2016
Resolution: Rectified on the spot prior to Coast Guard examiner departure.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 17 February 2010
Resolved
Two dry chemical and one foam extinguishers are wasted. 70C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2010
Resolution: Vessel submitted invoice and pictures attesting to the replacement extinguishers on board their vessel. Def lifted.
Stability › Watertight Integrity › General
Issued 17 February 2010
Resolved
The ballast water suction line has a quarter size soft patch before the valve. 17 A C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2010
Resolution: [name withheld] REPORT. ALL SAT
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 August 2005
Resolved
Elevator door on "F" deck does not lock when elevator lowers. Secure elevator until permanent repairs are made.
SOLAS CH II-2 reg 26.1
Action required: 705 - Other - as specified
Due 7 September 2005
Resolved 9 August 2005