MAURY USCG vessel records Sign in
← All vessels

RUDEE WHALER

RUDEE WHALER is a 2002 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 2002, most recently in April 2026, along with 48 deficiencies and 1 casualty investigation in 2005.

Records from 2002 to 2026. Most recent: inspection, 14 April 2026.

Built
2002
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI4684
566209
Flag
UNITED STATES
367701020
Maury page id
psix-566209

Inspections, by type

…with no type recorded5
Years with a record 19 calendar years (2002–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 20.0 ft × 10.0 ft
Registered tonnagegross 87 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPERFORMANCE MARINE INC · ARUNDEL, ME, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVIRGINIA BEACH, VA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 4 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Simplified, Net Ton
87 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4684MMSI 367701020 · active · compulsorily equipped · granted 21 August 2025, expires 4 November 2035
WDC5884MMSI 367047930 · expired · compulsorily equipped · granted 7 June 2005, cancelled 8 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

14 April 2026 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8330578
6 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8265257
7 April 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8103289
30 October 2024 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8026869
2 April 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888586
6 November 2023 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7820972
10 September 2023 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7789081
10 September 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7821374
16 May 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7690590
18 April 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7666329
9 March 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7648265
17 November 2022 Examination of Repairs · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7593890
29 March 2022 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7417406
19 January 2022 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7382562
7 May 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7191670
20 April 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7177390
4 November 2020 Drydock Exam · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7087319
1 June 2020 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6960638
22 April 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6664784
20 November 2018 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6574437
23 April 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6397780
7 April 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6119796
29 March 2017 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6110794
3 November 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6023696
25 May 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5886761
25 April 2016 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5857371
30 March 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3447028
28 January 2009 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3401581
6 May 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3199973
9 April 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3180409
23 April 2007 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2905845
12 January 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2863840
27 October 2006 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2809166
15 May 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2647814
23 August 2005 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2472585
25 June 2005 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2410134
24 June 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2404695
17 June 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2393333
25 May 2005 In-Service Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2367663
19 January 2005 Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2277033
23 September 2004 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2203038
7 September 2004 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2202873
16 July 2004 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2134289
2 May 2003 Hull Examination · Internal Structural Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1787270
28 June 2002 COI Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1638470

Deficiency record · 48

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 April 2026 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] observed no emergency marking in accommodation space & on emergency exits for engine room. Vessel operator installed emergency marking during inspection. 46 CFR 185.606
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2026 Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support, except that on vessels of not more than 19.8 meters (65 feet) in length, installations in accordance with paragraph 14.h of ABYC E-8 and paragraph 15.h of ABYC E-9 (both incorporated by reference; see 46 CFR 175.600) are acceptable as meeting the requirements of this section. MI observed plastic cable mounts in pilot house. vessel operator installed metal cable ties during inspection. 46 CFR 183.340(b)(4)
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Outlet behind the concession stand was not properly secured. 46 CFR 183.200 (b)
Action required: 10 - Deficiency Rectified
Due 7 April 2025
Resolved 7 April 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). As per IMO Resolution A.658(16), Retro-reflective materials of a sufficient width (approximately 5 cm) should be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. The ring life buoy only had three pieces of retro-reflective tape. 46 CFR 185.604(i) IMO RESOLUTION A.658(16)
Action required: 10 - Deficiency Rectified
Due 7 April 2025
Resolved 7 April 2025
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2024 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by Commandant. Fuel hoses were found to be deteriorated & outer covering dry rotted on port main diesel engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: Vessel had fuel hoses changed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel must repair damage to the forward bow hand rail, both sides of the spray rail, and ensure bolts for hull splash guard are water tight prior to carrying passengers. 46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2023
Resolved 14 September 2023
Resolution: O/O made temp repairs
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 April 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications Vessel has out of date Navigation rules publication
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 26 April 2023
Resolution: Replaced with up to date copy
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 April 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules... Vessel's mast head light lens obstructs light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 26 April 2023
Resolution: Replaced lense
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 28 July 2022 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz. Vessel does not have an MF-DSC radio installed on board. Vessel will need to install one, or apply for a FCC wavier IAW SPV Checklist (revision 2019.05.16) Until this is rectified, the vessel will be restricted to operating under 20 NM from land.
Action required: 705 - Other - as specified
Resolved 16 May 2023
Resolution: Radio Installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 March 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The engine room natural ventilation covers do not close sufficiently.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2022
Resolution: Installed ventilation cover's that made a good seal. All sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 March 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of a single screen of corrosion resistant wire of a least 30x30 mesh. The fuel tank vent does not have a screen.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2022
Resolution: Installed a 30x30 mesh screen. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 March 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar publication and Coast Guard Light list. Coast Pilot and light list are not current (2019)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2022
Resolution: New navigational publication's were on board. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 January 2022 Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. All of the vesel's lifefloats had cinched covers over the tops of them while passengers were embarked.
Action required: 10 - Deficiency Rectified
Resolved 19 January 2022
Resolution: Vessel operator had all of the lifefloat covers removed prior to getting underway with passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2021 Resolved
Vessel had cut corroded bilge pipe in #2 hold and repaired with soft patch. Repair was made prior to OCMI approval. Vessel is required to submit repair plan prior to completion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 7 May 2021
Resolution: Number two hold bilge suction line was repaired in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 November 2020 Resolved
Aft port side gel coat and fiberglass damage needs repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2020
Resolved 5 November 2020
Resolution: Vessel owner scarfed and applied fiberglass to good material and resealed gel coat.
Fire Fighting › Fire Hoses › Condition
Issued 29 March 2017 Resolved
Fire hose burst during hydrostatic testing. Replace with an approved fire hose to the satisfaction of the attending CG Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2017
Resolved 29 March 2017
Resolution: Replaced with an approved fire hose prior to departure of CG Marine Inspector.
Fire Fighting › Fire Pumps › Pressure
Issued 29 March 2017 Resolved
The pressure guage for the fire pump was inoperative. Replace to the satisfaction of the attending CG Marine Inspector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2017
Resolved 29 March 2017
Resolution: The pressure gauge was satisfactorily tested for operation prior to the departure of the CG Marine Inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2017 Resolved
Found dead end wires with no terminal connectors under the steering console. Install pressure type connectors on each dead end wire to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 7 April 2017
Resolution: Dead end wires that were observed under the vessel's steering console were removed.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 March 2017 Resolved
Found expired items in the first aid kit. Replace expired items to comply with 46 CFR 160.041 to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 7 April 2017
Resolution: The vessel rep had replaced the expired items in the first aid kit in kind and in compliance with 46 CFR 160.041.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2016 Resolved
Found incomplete first aid kit. renew kit to conform to 46 CFR 160.041 to the satisfaction of a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: New first aid kit was inspected and found in compliance with 46 CFR 160.041, all sat.
Fire Fighting › Ventilation Systems › Fans
Issued 25 April 2016 Resolved
Mechanical ventilation in engine room did not shut down upon actuation of pre-engineered fixed firefighting system. Demonstrate proper auto shutdown to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Mechanical ventilation was replaced in-kind and proper auto shutdown was demonstrated
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 25 April 2016 Resolved
Pre-engineered fixed firefighting system’s bottle overdue for hydrostatic test. Hydo bottle or perform the optional 5 yr visual exam by a DOT authorized servicing company with a Requalification Identification Number.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: A new pre-engineered fire boy system was installed capable of providing 2,750 cubic feet of protection. Rough Measurements were taken of the machinery space at 2,400 cubic feet.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 9 April 2008 Resolved
Provide Letter of Designation of Senior Deckhand(s) as required by vessel's current valid COI in accordance with NVIC 1-91.
Due 16 April 2008
Resolved 9 April 2008
Resolution: Owner provided Letter of Designation of Senior Deckhand(s) as required by vessel''''''''''''''''s current valid COI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 April 2008 Resolved
Install visible alarms at the operating station for automatic bilge pump.
Condition: Unknown
Due 23 April 2008
Resolved 6 May 2008
Resolution: Observed test of automatic bilge alarm indicators (audible and visable).
Fire Fighting › Fire Hoses › Condition
Issued 23 April 2007 Resolved
Replace holed fire hose w/ approved UL19 fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2007
Resolution: Installed approved hose, ops checked w/ no leaks found.
Fire Fighting › Fire Main › Pressure
Issued 23 April 2007 Resolved
Provide pressure gage on output side of fire pump.
Due 30 April 2007
Resolved 23 April 2007
Resolution: Pressure gage installed, pump pressure indicated 60 psi.
Lifesaving › Lifefloat › Painter
Issued 23 April 2007 Resolved
Replace painters on all three stacks of life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 1 May 2007
Resolution: Three new painter lines attached to life float stacks.
Lifesaving › Lifefloat › Lifeline
Issued 23 April 2007 Resolved
Replace all grab lines, pendants on all life floats as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 1 May 2007
Resolution: Replaced new grab lines, pendants on life floats.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 April 2007 Resolved
Install LF floating light lanyards on all seven life floats. Lanyards are too short and not of approved material.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 1 May 2007
Resolution: Replaced lanyards to floating lights.
Lifesaving › Lifefloat › Paddle
Issued 23 April 2007 Resolved
Replace five broken sets of lifefloat paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 1 May 2007
Resolution: Five new lifefloat paddles installed.
Lifesaving › Lifefloat › Serviceable
Issued 23 April 2007 Resolved
Install suitable spacer material between all LF's.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 1 May 2007
Resolution: All stacked life floats have suitable spacer material between lifefloats.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 April 2007 Resolved
Provide accurate labeling of mismarked bilge high water alarms.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 1 May 2007
Resolution: All high water alarms properly labeled in pilothouse.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 April 2007 Resolved
Install exhaust lagging on port engine (outboard exhaust pipe) fwd of cooling line.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 1 May 2007
Resolution: Exhaust lagging installed.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 23 April 2007 Resolved
Provide metallic supports for cabling in engine room, above both engines.
Due 30 April 2007
Resolved 23 April 2007
Lifesaving › Lifefloat › Markings
Issued 23 April 2007 Resolved
Mark all lifefloats w/ vessel's name and number of persons.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 1 May 2007
Resolution: All lifefloats properly marked.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 May 2006 Resolved
Vessel restricted to 152 persons until two additional adult lifejackets placed on board.
Due 22 May 2006
Resolved 18 May 2006
Resolution: Two properly marked adult lifejackets were placed on board.
Navigation › Piloting/Steering › Marine Charts
Issued 15 May 2006 Resolved
Provide proof that navigation charts are current to the satisfaction of the Marine Inspector
Due 22 May 2006
Resolved 30 June 2006
Stability › Watertight Integrity › General
Issued 15 May 2006 Resolved
Install forepeak keeper device, and gasket material to satisfaction of marine inspector.
Due 22 May 2006
Resolved 18 May 2006
Resolution: Installed keeper device and repaired gasket.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2006 Resolved
Install machinery guard over rotating fire pump belts.
Due 22 May 2006
Resolved 30 June 2006
Resolution: Newly fabricated machinery guard placed over rotating belt for fire pump on port engine.
Stability › Watertight Integrity › General
Issued 15 May 2006 Resolved
Replace two cracked port and starboard windows in pilothouse.
Due 15 June 2006
Resolved 30 June 2006
Resolution: Port and stbd pilothouse side windows were replaced.
Stability › Watertight Integrity › General
Issued 15 May 2006 Resolved
Make salon storage compartment, and lazarette compartment bulkheads watertight. (6 bulkhead penetrations need to be sealed)
Due 22 May 2006
Resolved 30 June 2006
Resolution: All bulkhead penetrations are water tight.
Lifesaving › Lifefloat › Markings
Issued 25 May 2005 Resolved
Provide proper stenciling of Number of persons on each life float.
Condition: Unknown
Due 8 June 2005
Resolved 17 June 2005
Resolution: Stenciled all life floats.
Lifesaving › Lifefloat › Paddle
Issued 25 May 2005 Resolved
Provide two 4' paddles properly stenciled and stowed for each life float.
Condition: Unknown
Due 8 June 2005
Resolved 17 June 2005
Resolution: Provided two 4'' paddles, stenciled and stowed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 July 2004 Resolved
Provide 3'-6' lanyard with clip for lifebuoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 July 2004
Resolved 21 July 2004
Resolution: Received phone call that lanyard with clip was provided.
Engineering › Fuel Oil Service System › Piping
Issued 16 July 2004 Resolved
Repair fuel leak on return line generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 16 July 2004
Communications › Radio Communications › EPIRB
Issued 16 July 2004 Resolved
Replace outdated hydro release.
Action required: 705 - Other - as specified
Due 23 July 2004
Resolved 21 July 2004
Resolution: Received phone call that hydro release was replaced.
Engineering › Fuel Oil Service System › Valve
Issued 16 July 2004 Resolved
Provide a cable on the stbd emergency shutoff valve. Its currently located under a refridgerator in the concession area. The energency shutoff also needs to be properly labeled.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 August 2004
Resolved 21 July 2004
Resolution: Received phone call that the items were corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 28 June 2002 Resolved
PROVIDE ADDITIONAL BII PORTABLE F.E. LEGACY COMPONENT DESC: provide
Condition: Unknown
Due 28 June 2002
Resolved 30 June 2002

Casualty record · 1

24 June 2005Routine · role: Involved in a Marine Casualty · at RUDEE INLET BRIDGE · activity 2404695
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.