Records from 2017 to 2021. Most recent: inspection, 25 March 2021.
Documentation record
Tonnage as PSIX records it47423 - Convention (Subpart B), Net Ton
149995 - Dead Weight, Ton
172555 - Displacement, Ton
79525 - Regulatory (Subpart C or D), Gross Ton
47423 - Regulatory (Subpart C or D), Net Ton
79525 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 9
25 March 2021
COC-TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162407
17 November 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7096926
28 December 2019
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6869417
11 December 2019
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6872000
11 December 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6872007
1 July 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6732563
1 July 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6732594
28 December 2018
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6600873
6 November 2017
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6297694
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2021
Resolved
After any survey of the ship under regulations 7,8,9,or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed additional (02) Analyzer systems were installed in the IGS system with no Class approval.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2021
Resolution: Received satisfactory DNV-GL class report attesting to the approved installation and operation of both inert gas oxygen analyzers.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 December 2019
Resolved
The tank overfill alarm required by paragraph a of this section must be identified with the legend "TANK OVERFILL ALARM" in black letters at least 50.8 millimeters (2 inches) high on a white background. PSCO discovered vessel has red tank overfill alarm letters on a white background.
46CFR39.2007(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2020
Resolved 17 November 2020
Resolution: The Astra submitted proper documentation to Sector LA/LB to resolve the deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 6 November 2017
Resolved
In a ship in which is used, the arrangements for the distribution of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Fuel pumps 1 and 6 for the MDE were found to be leaking. 74SOLAS(01)II-2/15.2; 50AC
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 29 November 2017
Resolution: See attached survey report.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 6 November 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Identified cracks in the incinerator door fram as well as brink from the inner wall crumbling off. 74SOLAS(14)I/11(a); 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2017
Resolution: See attached survey report.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 November 2017
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey, without the sanctionof the Administration. Soft patches were found on the heat exchanger waater lines for the ship service generator. 74SOLAS(14)I/11(b); 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 November 2017
Resolution: See attached survey report.
Lifesaving › Lifeboat › Markings
Issued 6 November 2017
Resolved
All life-saving appliances & arrangements shall comply w/ the applicable requirements of teh Code. Means of identifying the ship to which the lifeboat belongs & number of lifeboats shall be marked so visible from above. Both port and stbd topside means of identification are missing. 74SOLAS(14)III/34; LSA IV/4.4.9.3; 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 November 2017