MAURY USCG vessel records Sign in
← All vessels

EPIC BERMUDA

EPIC BERMUDA is a 2001 tank ship. The Coast Guard has recorded 24 inspections since 2002, most recently in February 2020, along with 14 deficiencies and 4 operational controls.

Records from 2002 to 2020. Most recent: inspection, 27 February 2020.

Built
2001
Last inspected
27 February 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9238131 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
567180
Flag
MALTA
—
Maury page id
psix-567180

Inspections, by type

…with no type recorded13
Years with a record 4 calendar years (2002–2020)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1999 - Convention (Subpart B), Net Ton
6624 - Dead Weight, Ton
10179 - Displacement, Ton
5764 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

27 February 2020 COC-GAS Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6915171
27 June 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5921770
26 June 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5922814
22 March 2016 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5835830
16 March 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5834432
1 February 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5807231
30 January 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5806442
10 August 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2158084
10 August 2004 PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2162023
10 August 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2167793
5 August 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2156868
12 June 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2124932
10 May 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2070489
10 May 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390417
19 April 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2046400
19 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2049208
19 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390319
10 April 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2037816
10 April 2004 MARPOL Annex I Examination · Ballast Water Examination · Letter of Compliance (Initial/Renewal)
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2041363
9 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2042222
9 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390199
18 December 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1721503
26 July 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1652596
23 May 2002 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1619790

Deficiency record · 14

Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 22 March 2016 Resolved
1099-Gas detection equipment should be so designed that it may readily be tested. Crew could not demonstrate proper testing of the flow failure alarm. SOLAS 74 (2014) VII/31.1; IGC Code (1993) 13.6.6, 50ac
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 27 June 2016
Resolution: Received class report attesting that the flow meter is repaired and fully operational.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 10 August 2004 Resolved
Properly set vapor boundaries prior to conducting cargo operations.
Action required: 705 - Other - as specified
Resolved 10 August 2004
Fire Fighting › Miscellaneous Items
Issued 10 April 2004 Resolved
Provide/ post fire fighting instructions for fwd paint locker. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2004
Navigation › Piloting/Steering
Issued 10 April 2004 Resolved
Provide corrected chart for St. Croix. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2004
Deck/Cargo
Issued 10 April 2004 Resolved
relocate remove excess chemicals in chemical locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2004
Lifesaving › Rescue Boat Equipment
Issued 10 April 2004 Resolved
Renewal rescue boat fuel gage.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 10 April 2004 Resolved
Provide face sheild in battery locker.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 April 2004 Resolved
Properly Torque CO2 flexible hose fittings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2004
Documentation › Certificates/Documents
Issued 10 April 2004 Resolved
Provide roser iaw 13(a)(6) of COC Subchapter O endorsment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2004
Fire Fighting
Issued 9 April 2004 Resolved
Make repairs/clear (of salt deposits/paint) cargo area firfighting nozzles. (corrected on the spot)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2004
Operations/Management › Mandatory Ship Reporting Systems
Issued 23 May 2002 Resolved
VESSEL COULD PROVIDE NO EVIDENCE THAT MAINTENANCE REQUIRED BY SMS SYSTEM WAS BEING COMPLETED. LEGACY COMPONENT DESC: Entry Report
Due 18 August 2002
Resolved 23 May 2002
Operations/Management › Vessel Safety Management
Issued 23 May 2002 Resolved
VESSELS MASTER WAS NOT FAMILIAR WITH THE VESSEL`S SAFETY MANAGMENT. LEGACY COMPONENT DESC: Resources and Personnel
Due 18 August 2002
Resolved 23 May 2002
Documentation › Manuals/Policy Documentation
Issued 23 May 2002 Resolved
VESSEL COULD NOT PROVIDE LIST OF CRITICAL EQUIPMENT. LEGACY COMPONENT DESC: Emergency Instructions
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2002
Fire Fighting › Means of Escape
Issued 23 May 2002 Resolved
VESSEL DOES NOT HAVE THE REQUIRED NUMBER OF SPARE SCBA CYLINDERS ON BOARD
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2002