← All vessels
EPIC BERMUDA
EPIC BERMUDA is a 2001 tank ship. The Coast Guard has recorded 24 inspections since 2002, most recently in February 2020, along with 14 deficiencies and 4 operational controls.
Records from 2002 to 2020. Most recent: inspection, 27 February 2020.
- Built
- 2001
- Last inspected
- 27 February 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9238131 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HGF9
567180
Flag
MALTA
—
Maury page id
psix-567180
Inspections, by type
…with no type recorded13
Years with a record
4 calendar years (2002–2020)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1999 - Convention (Subpart B), Net Ton
6624 - Dead Weight, Ton
10179 - Displacement, Ton
5764 - Convention (Subpart B), Gross Ton
6624 - Dead Weight, Ton
10179 - Displacement, Ton
5764 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
27 February 2020
COC-GAS Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6915171
27 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5921770
26 June 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5922814
22 March 2016
COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5835830
16 March 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5834432
1 February 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5807231
30 January 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5806442
10 August 2004
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2158084
10 August 2004
PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2162023
10 August 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2167793
5 August 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2156868
12 June 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2124932
10 May 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2070489
10 May 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390417
19 April 2004
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2046400
19 April 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2049208
19 April 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390319
10 April 2004
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2037816
10 April 2004
MARPOL Annex I Examination · Ballast Water Examination · Letter of Compliance (Initial/Renewal)
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2041363
9 April 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2042222
9 April 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390199
18 December 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1721503
26 July 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1652596
23 May 2002
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1619790
Deficiency record · 14
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 22 March 2016
Resolved
1099-Gas detection equipment should be so designed that it may readily be tested. Crew could not demonstrate proper testing of the flow failure alarm. SOLAS 74 (2014) VII/31.1; IGC Code (1993) 13.6.6, 50ac
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 10 August 2004
Resolved
Properly set vapor boundaries prior to conducting cargo operations.
Fire Fighting › Miscellaneous Items
Issued 10 April 2004
Resolved
Provide/ post fire fighting instructions for fwd paint locker. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Navigation › Piloting/Steering
Issued 10 April 2004
Resolved
Provide corrected chart for St. Croix. LEGACY COMPONENT DESC: Marine Charts
Deck/Cargo
Issued 10 April 2004
Resolved
relocate remove excess chemicals in chemical locker.
Lifesaving › Rescue Boat Equipment
Issued 10 April 2004
Resolved
Renewal rescue boat fuel gage.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 April 2004
Resolved
Provide face sheild in battery locker.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 April 2004
Resolved
Properly Torque CO2 flexible hose fittings.
Documentation › Certificates/Documents
Issued 10 April 2004
Resolved
Provide roser iaw 13(a)(6) of COC Subchapter O endorsment.
Fire Fighting
Issued 9 April 2004
Resolved
Make repairs/clear (of salt deposits/paint) cargo area firfighting nozzles. (corrected on the spot)
Operations/Management › Mandatory Ship Reporting Systems
Issued 23 May 2002
Resolved
VESSEL COULD PROVIDE NO EVIDENCE THAT MAINTENANCE REQUIRED BY SMS SYSTEM WAS BEING COMPLETED. LEGACY COMPONENT DESC: Entry Report
Operations/Management › Vessel Safety Management
Issued 23 May 2002
Resolved
VESSELS MASTER WAS NOT FAMILIAR WITH THE VESSEL`S SAFETY MANAGMENT. LEGACY COMPONENT DESC: Resources and Personnel
Documentation › Manuals/Policy Documentation
Issued 23 May 2002
Resolved
VESSEL COULD NOT PROVIDE LIST OF CRITICAL EQUIPMENT. LEGACY COMPONENT DESC: Emergency Instructions
Fire Fighting › Means of Escape
Issued 23 May 2002
Resolved
VESSEL DOES NOT HAVE THE REQUIRED NUMBER OF SPARE SCBA CYLINDERS ON BOARD
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.