MAURY USCG vessel records Sign in
← All vessels

ELKA BENE

ELKA BENE is a 2002 tank ship. The Coast Guard has recorded 39 inspections since 2002, most recently in November 2021, along with 5 deficiencies and 4 operational controls.

Records from 2002 to 2021. Most recent: inspection, 8 November 2021.

Built
2002
Last inspected
8 November 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9234496 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
567339
Flag
LIBERIA
—
Maury page id
psix-567339

Inspections, by type

…with no type recorded15
Years with a record 12 calendar years (2002–2021)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11067 - Convention (Subpart B), Net Ton
45467 - Dead Weight, Ton
48196 - Displacement, Ton
30770 - Regulatory (Subpart C or D), Gross Ton
11067 - Regulatory (Subpart C or D), Net Ton
30770 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

8 November 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7347203
22 July 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7264568
26 August 2019 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6792489
20 August 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6784245
22 January 2019 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6612654
14 August 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6511385
26 August 2016 COE-Dockside · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5984129
2 August 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5960587
2 August 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5960592
15 August 2015 ISPS II Exam · COC-CHEM & TVE Renew · Deficiency Check · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5216456
20 November 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3367091
22 September 2008 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3330465
12 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2905848
25 January 2007 MARPOL Annex II Examination · Random ISPS/MTSA-No PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2861795
19 July 2006 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex II Examination · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2717407
13 May 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2649590
9 May 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2644521
11 January 2006 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2565046
28 August 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2476929
28 August 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2479324
24 August 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2573448
9 June 2005 ILO-147 Exam · STCW 95 Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2384904
9 June 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2384924
28 May 2005 MARPOL Annex V Examination · Random ISPS/MTSA/PSC · Ballast Water Examination · COC-CHEM Annual · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2370573
8 January 2005 Random ISPS/MTSA/PSC · Ballast Water Examination · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2271108
3 January 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2268143
21 December 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2263467
8 December 2004 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2255749
3 December 2004 Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2251372
3 September 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2185688
1 July 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2111788
31 May 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2086495
17 May 2004 Letter of Compliance (Initial/Renewal) · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2067352
17 May 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2070515
17 May 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2390445
8 May 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2062336
7 July 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1837976
12 February 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1743618
20 May 2002 Security Inspection · Certificate of Compliance · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1617546

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 July 2021 Resolved
the resistance of doors shall be, as far as practicable, be equivalent to that of the dividsion in which they are fitted. Class B, crew messroom passage way door has a hole drilled in it making it no longer equivalent to the division to which it is fitted.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2021
Resolution: Received class report. Closed deficiency.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 15 August 2015 Resolved
1899-Other(Tankers)-The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.. PSCO discovered failures on both Inert Gas Generator diesel oil fuel pumps. Pump A had water inside the motor insulation and Pump B experienced a motor failure.- 74 SOLAS (09) I/11.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2015
Resolved 20 August 2015
Resolution: Received class report and PSCO''''s observed IG system with operable fuel system.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 15 August 2015 Resolved
1899-Other (tankers) PSCO conducted tests of the Blower Failure and Scrubber low water pressure, in both instances the GRV and all other associated automatic valves failed to operate. Further investigation by the PSCO revealed that the pneumatic controls to all automatic valves were disconnected and that the crew was using one manual butterfly valve to regulate the system pressure other modes also
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2015
Resolution: An attending ABS surveyor verified that the pneumatic lines were connected and tested the IGS. The O2 connection was also verified by the surveyor and found to be satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 December 2004 Resolved
Self Cosing device on Emergency Escape door located adjacent to shaft on bottom flat of engine room will not close as a pipe is obstructing the self closing device. To the satisfaction of class or a Coast Guard inspector.
Due 17 December 2004
Resolved 8 December 2004
Resolution: DEF Check boarding conducted by PO Leasure, PO Stout, and PO Guillemette confirming repairs have been completed to the satisfaction of the Boarding officer.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 December 2004 Resolved
Self closing door between officers mess and galley will not shut when magnetic door release is activated. To the satisfaction of class or a Coast Guard Inspector. Until item is completed, door is to remain closed and magnetic door release not to be used.
Due 17 December 2004
Resolved 8 December 2004
Resolution: DEF Check boarding conducted by PO Leasure, PO Stout, and PO Guillemette confirming repairs have been completed to the satisfaction of the Boarding officer.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.