MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 22

STRETCH DUCK 22 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2002, most recently in September 2019, along with 23 deficiencies — 2 with no resolution recorded —.

Records from 2002 to 2019. Most recent: inspection, 21 September 2019.

Built
1945
Last inspected
21 September 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB 5662
567380
Flag
UNITED STATES
—
Maury page id
psix-567380

Inspections, by type

…with no type recorded3
Years with a record 13 calendar years (2002–2019)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Net Ton
9 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

21 September 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6830130
19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788034
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622657
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519694
13 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6510298
12 June 2017 Internal Structural Exam · Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6167625
25 January 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6077163
22 June 2016 Administrative Inspection · Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5915875
9 August 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4112500
19 January 2011 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3928891
12 May 2009 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3473447
11 December 2008 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3378362
11 January 2008 Annual Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3128772
19 January 2007 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2858411
2 June 2006 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2668715
29 May 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2674784
25 January 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2572850
24 October 2005 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2521020
28 June 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2415114
20 June 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2406520
1 April 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2343159
13 September 2004 Simplified Stability Test
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2194503
24 March 2004 Construction Oversight · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2040855
22 May 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1798971
16 September 2002 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1676351
8 May 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1617614

Deficiency record · 23

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new Conditions of Operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 September 2018 No resolution recorded
Prior to carrying passengers for hire conduct underway portion of Annual Inspection to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2018 Resolved
Side curtain release for port side got hung up on aft clip. Item was repaired by placing a spacer nut between the release hook and pin. When re-tested side curtain released properly. Corrected on spot.
Action required: 10 - Deficiency Rectified
Resolved 18 September 2018
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 June 2017 Resolved
Vessel operator to provide a list of approved plans and weight ticket for modifications applicable to this vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Received email containing approved plan index and weight ticket for this vessel.
Construction/Loadline › Hull › Bottom Plating
Issued 22 June 2016 Resolved
Replace padeyes for bridal and crop/ renew bad steel in these areas. Submit repair plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2016
Resolution: Air test complete. No visual signs of weld failure.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 January 2011 Resolved
Repair broken jacket water hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2011
Resolution: Witnessed installation of new hose.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 January 2011 Resolved
Prove compliance with 46 CFR 182.720(e) regarding flexible non-mettalic hose for jacket water systems.
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 19 April 2011
Resolution: Administratively cleared. Current instalation accepted.
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2008 Resolved
Prove proper front fenderwell delamination repairs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Resolution: Witnessed test of repairs, all sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 January 2007 Resolved
Conduct drills
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2007
Resolved 2 March 2007
Resolution: Witnessed satisfactory drills on DUKW 51
Fire Fighting › Fixed Fire Detection System › Approval
Issued 19 January 2007 Resolved
Prove proper operation of fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2007
Resolved 9 April 2007
Resolution: System modified & tested sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 January 2006 Resolved
Conduct drills prior to carrying passengers. Owner's rep requested drill be conducted at a later date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2006
Resolved 1 March 2006
Resolution: Drills conducted on DUKW 48.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 1 April 2005 Resolved
Provide proper Marpol, oil discharge and emergency broadcast placards as need.
Due 1 May 2005
Resolved 20 April 2005
Resolution: Provided placards.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 1 April 2005 Resolved
Proved proper way to discharge anchors.
Due 1 May 2005
Resolved 20 April 2005
Resolution: Provided proper way.
Electrical › Electric Supply System (service) › Cable
Issued 1 April 2005 Resolved
Properly secure wiring under the dash.
Due 1 May 2005
Resolved 20 April 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2004 Resolved
Provide blanket for Man Overboard. LEGACY COMPONENT DESC: Medicine Chest
Due 24 April 2004
Resolved 19 April 2004
Resolution: Provided blanket.
Construction/Loadline › Structures
Issued 18 March 2004 Resolved
Fix pulls on floor boards.
Condition: Design Flaw
Due 24 April 2004
Resolved 19 April 2004
Resolution: Fixed pulls.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2004 Resolved
Provide latches for jumpseat.
Condition: Design Flaw
Due 24 April 2004
Resolved 19 April 2004
Resolution: Provided latches.
Engineering › Fuel Oil Storage/Transfer System
Issued 18 March 2004 Resolved
Stow fuel line a safe distance frm shaft. LEGACY COMPONENT DESC: Hose
Condition: Design Flaw
Due 24 April 2004
Resolved 19 April 2004
Resolution: Stowed hose.
Engineering › Freshwater System (jacketwater cooling)
Issued 18 March 2004 Resolved
Fix brackets on keel coolers. LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Due 24 April 2004
Resolved 19 April 2004
Resolution: Fixed brackets.
Navigation
Issued 22 May 2003 Resolved
Provide an VHF radio, FCC Station License, Radio Safety Certificate and Operator Permit.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided documents.
Deck/Cargo
Issued 22 May 2003 Resolved
Provide an easily deployed anchoring system.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided anchoring system.
Operations/Management
Issued 22 May 2003 Resolved
Provide state registration numbers of this vessel.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided registration.
Operations/Management
Issued 22 May 2003 Resolved
Provide a specific stability letter for this vessel.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided stability letter.

Ownership record