MAURY USCG vessel records Sign in
← All vessels

YM ZENITH

YM ZENITH is a 1996 freight ship. The Coast Guard has recorded 31 inspections since 2002, most recently in May 2012, along with 11 deficiencies and 4 operational controls.

Records from 2002 to 2012. Most recent: inspection, 15 May 2012.

Built
1996
Last inspected
15 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9118317 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
567395
Flag
TAIWAN
—
Maury page id
psix-567395

Inspections, by type

…with no type recorded12
Years with a record 10 calendar years (2002–2012)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46697 - Convention (Subpart B), Gross Ton
21375 - Convention (Subpart B), Net Ton
45995 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

15 May 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4304357
11 March 2010 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3689962
12 January 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3392868
16 December 2008 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3380963
5 October 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3338882
30 July 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3283798
23 June 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3239348
18 July 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2999659
3 July 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2981963
30 May 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2946869
28 July 2006 ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2727346
26 July 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2725754
8 February 2006 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2581505
24 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2520642
23 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2526168
29 June 2005 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2407530
12 May 2005 ILO-147 Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Loadline Exam · STCW 95 Exam · ISM Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2355987
7 September 2004 PII Safety Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2189289
3 September 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2192090
2 September 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2184197
2 September 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2185082
20 May 2004 MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2073098
2 January 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1973903
14 July 2003 Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1846062
10 July 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1845745
4 July 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1834723
27 July 2002 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1652908
23 June 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1636203
22 May 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1619245
19 May 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1618262
18 May 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1624515

Deficiency record · 11

Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 December 2008 Resolved
1230 The guard rails located aft of both gangway ladders are below the 1 meter requirement of ICLL. When gangway ladders are down in port this creates a safety hazard. Satisfaction of class 70 a/b
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 December 2008
Resolved 12 January 2009
Resolution: PSC INSPECTOR RECIEVED TECH REPORT. ALL SAT
Fire Fighting › Structural - A Class Divisions › Doors
Issued 16 December 2008 Resolved
0710 Numerous A-Class fire doors designed to be self closing, were found with hold back devices: Passageway, Main Deck, Engine Room. Satisfaction of class. 70 a/b
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 December 2008
Resolved 12 January 2009
Resolution: PSC INSPECTOR RECIEVED TECH REPORT. ALL SAT
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 5 October 2008 Resolved
During pre-arrival test to the port of Los Angeles/Long Beach, vessel reported loss of astern propulsion. Provide a classification report attesting to the proper operation of the propulsion engine forward and astern to the U.S. Coast Guard Sector Los Angeles/Long Beach office.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 October 2008
Resolution: ABS Class report dated 07OCT2008.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 5 October 2008 Resolved
Vessel experienced loss of adequate diesel start air pressure during attempts to shift astern propulsion. Provide a classification report attesting to the proper operation of the diesel start air to the U.S. Coast Guard Sector Los Angeles/Long Beach office.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 October 2008
Resolution: ABS class report provided dated 07OCT2008.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 30 May 2007 Resolved
Emergency generator did not immediately start due to clogged air filter. 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 June 2007
Resolution: Crew replaced the air filter, and were able to start the emergency generator.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 30 May 2007 Resolved
Lifelines on port side of port lifeboat are worn. 40a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2007
Resolved 6 June 2007
Resolution: Received class report stating "[T]he lifeline on the outboard side (port side) of the Port lifeboat had been replaced with a new line, utilizing the original floats, to the satisfaction of the attending Surveyor."
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 May 2005 Resolved
Category A door leading to machinery space located on stack house is not reasonably gas tight.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 May 2005
Resolved 29 June 2005
Resolution: Received class report correcting/testing repairs.
Navigation › Piloting/Steering › Gyro Compass
Issued 3 September 2004 Resolved
Vessel wishes to enter the Port of New York with an inoperable gyro compass and has made arrangments to effect repairs prior to departing the port. Vessel is authorized to deviate from the regulations contained in title 33 CFR and enter the Port of New York. The vessel must be in full compliance before departing the Port of New York.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2004
Resolution: Vessel is full compliance and has faxed this office a copy of the technical report showing repairs.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 September 2004 Resolved
Vessel has inoperable Gyro Compass. Requested Letter of Deviation to enter the port of Savannah.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 September 2004
Resolved 7 September 2004
Resolution: Item was found to be operational by MSO Wilmington during a NPV Exam.
Accommodation/Occupational Safety › Occupational Safety
Issued 19 May 2002 Resolved
BROKEN STAR WELL WELDS NEAR #1 PISTON , OBTAIN CLASS REPORT SHOWING REPAIRS MADE PRIOR NEXT US PORT AFTER FORIEGN
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 May 2002
Resolved 23 June 2002
Resolution: ALL REPAIRS MADE AND APPROVED BY CLASS
Accommodation/Occupational Safety › Occupational Safety
Issued 19 May 2002 Resolved
PROCTECTIVE COVERING ON EXTERIOR EXHAUST VENT(EMERGENCY GENERATOR) BURNED FIRE HAZARD.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 May 2002
Resolved 23 June 2002
Resolution: ALL COMPONENTS ON EXTERIOR EXHAUST VENT REPAIRED.

Ownership record