Documentation record
Registered dimensions (L × B × D)110.1 ft × 30.0 ft × 10.0 ft
Registered tonnagegross 297 / net 202
ITC dimensions (L × B × D)110.1 ft × 30.0 ft × 10.0 ft
ITC tonnageNot recorded
BuilderPETERSON & HAECKER LTD · BLAIR, NE, UNITED STATES · built 1944
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPADUCAH, KY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it202 - Regulatory (Subpart C or D), Net Ton
297 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 15 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
12 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7620792
21 April 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4840182
27 January 2014
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4789753
12 December 2013
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4770749
19 April 2013
Administration
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4572739
17 January 2013
Administration
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4518046
22 October 2010
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3877881
14 May 2007
Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2930159
10 March 2007
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2897690
24 September 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2785466
23 September 2006
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2786331
11 August 2006
Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2747506
11 August 2006
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2749620
17 July 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2715721
14 July 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2712359
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 18 April 2007
Resolved
EAP Hotline information not posted on vessel
Condition: Improper/Lack of Maintenance
Due 2 May 2007
Resolved 12 January 2023
Resolution: Vessel is inactive with outstanding deficiencies that will be addressed if and when an initial COI is completed.
Fire Fighting › Fire Pumps › Arrangement
Issued 18 April 2007
Resolved
There is no remote start for the fire pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2023
Resolution: Vessel is inactive with outstanding deficiencies that will be addressed if and when an initial COI is completed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 April 2007
Resolved
Excess oily water in the bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2023
Resolution: Vessel is inactive with outstanding deficiencies that will be addressed if and when an initial COI is completed.
Documentation › Markings/Placards › Warning Signs
Issued 18 April 2007
Resolved
Remote fuel shut off valve not properly marked.
Condition: Improper/Lack of Maintenance
Due 2 May 2007
Resolved 12 January 2023
Resolution: Vessel is inactive with outstanding deficiencies that will be addressed if and when an initial COI is completed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2006
Resolved
Bulbs for Nav lights are not vertical filament type. According to UL 1104/COLREGS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 11 August 2006
Resolved
Fire detection system not installed on vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Documentation › Markings/Placards › Official Number (US)
Issued 11 August 2006
Resolved
Offical number not found on interior of hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 11 August 2006
Resolved
All Life Ring Bouys on vessel need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2006
Resolved
Missing Life Ring Bouys Self Igniting Lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 August 2006
Resolved
Vessel Name was not on the Ring Bouys
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 August 2006
Resolved
Exterior Light cover missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 11 August 2006
Resolved
Missing one B-II fire extinguisher in Engine Room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 August 2006
Resolved
All emergency lights not working on the vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2006
Resolved
Loose wires found in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 August 2006
Resolved
Electrical boxes in engine room missing covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 August 2006
Resolved
Covers for lights in the engine room are missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Stability › Watertight Integrity › General
Issued 11 August 2006
Resolved
Port Rudder Tube found to be leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Operations/Management › Navigation Safety › Towing Maintenance/Failure/Reporting
Issued 11 August 2006
Resolved
Have all items on vessels worklist fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 11 August 2006
Resolved
Electrical mat for Panel is missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Engineering › Lubricating Oil Service System › Pump
Issued 11 August 2006
Resolved
Pump for oil to Main Engine is leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 August 2006
Resolved
Found excessive oil in the vessels bilge and in the Forward Hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2006
Resolution: Conducted dificiency check on vessel found to be corrected.