MAURY USCG vessel records Sign in
← All vessels

MS BIGGY

MS BIGGY is a 2002 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2002, most recently in April 2026, along with 82 deficiencies.

Records from 2002 to 2026. Most recent: inspection, 9 April 2026.

Built
2002
Last inspected
9 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA9337
567835
Flag
UNITED STATES
—
Maury page id
psix-567835

Inspections, by type

Years with a record 21 calendar years (2002–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

9 April 2026 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8345170
22 January 2026 Administrative Inspection · Drydock Exam · Hull Examination · Vessel Attendance
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8290081
10 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8077264
24 January 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7853818
22 December 2023 Administrative Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841705
10 January 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619534
4 January 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7375292
8 December 2021 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7364621
11 March 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7154604
27 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916841
16 January 2020 Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6891107
11 July 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6745550
22 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6613712
7 February 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6350995
23 January 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6342041
29 December 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6063573
14 March 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833999
12 January 2016 Internal Structural Exam · Hull Examination · Examination of Repairs · DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5795794
24 March 2014 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4821625
6 February 2012 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4231058
15 September 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4145745
2 November 2010 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3883142
20 September 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3849945
15 September 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3325202
20 November 2007 Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3087771
11 July 2007 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2989701
15 September 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2783524
23 August 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2757080
30 March 2006 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2612976
12 December 2005 Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2549910
21 November 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2538376
14 October 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2514499
8 August 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2451285
27 September 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2206713
13 January 2004 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1983256
11 December 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1946938
9 September 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1808565
24 June 2002 Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1635774
3 May 2002 Simplified Stability Test
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1618745

Deficiency record · 82

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 April 2026 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessels has gone past its drop dead date for its annual exam.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2026
Resolved 28 April 2026
Resolution: Vessel had a annual exam.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 April 2026 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Vessels captain did not poses a valid medical certificate. 46 CFR 10.301
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2026
Resolved 28 April 2026
Resolution: Verified captain had a valid passing medical exaluation done.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 14 April 2026 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel did not have proof they had conducted any drills for the year and there was no deckhand present to conduct drills for evaluation. Vessel must demonstrate drills to an MI prior to carrying passengers. 46 CFR 185.420
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2026
Resolved 28 April 2026
Resolution: Verified captain started a drill log.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2026 Resolved
A vessel of not more than 7.9 meters (26 feet) in length must carry a minimum of one life buoy of not less than 510 millimeters (20 inches) in diameter. Vessels ring bouy was found to be not serviceable and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 28 April 2026
Resolution: Vessel purchased a new life bouy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. Vessels port side bilge pump wires were twisted together with electrical tape. Additionally, the stbd side bilge alarm float switch was not mounted properly. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 28 April 2026
Resolution: Verified wires repaired and float switch was mounted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 April 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. vessels port side running light and all around light failed to operate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 28 April 2026
Resolution: Verified all nav lights were working.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2024 Resolved
Fire extinguishers are required to be maintained IAW NFPA 10. Vessel did not have a service report to indicate the fire extinguishers had been serviced.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2024
Resolved 6 June 2024
Resolution: Vessel sent in satisfactory evidence of deficiency completion.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 January 2024 Resolved
Vessel must have emergency instructions posted near the operating station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 6 June 2024
Resolution: Vessel sent in satisfactory evidence of deficiency completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2024 Resolved
Vessel must have posted a placard showing donning instructions for the vessels life jackets where passengers can see/read.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 6 June 2024
Resolution: Vessel sent in satisfactory evidence of deficiency completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 January 2024 Resolved
Vessels life bouy must be marked with Type II retro reflective tape. Vessels Life bouy's retro was in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 6 June 2024
Resolution: Vessel sent in satisfactory evidence of deficiency completion.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 4 January 2022 Resolved
Deckhand not enrolled in Drug and Alcohol program. 185.212
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 6 April 2022
Resolution: Deckhand provided documentation of completed drug test and enrollment in consortium.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 4 January 2022 Resolved
Flares expired 180.68
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2022
Resolution: purchased new flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 January 2022 Resolved
Aspirin expired. 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 7 January 2022
Resolution: purchased new aspirin
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 January 2022 Resolved
Missing portable light. 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2022
Resolved 7 January 2022
Resolution: purchased additional flashlight
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2022 Resolved
Ring Life Buoy in non serviceable condition 180.71
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2022
Resolution: purchased new ring buoy and stencilled accordingly
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2021 Resolved
Fire extinguishers are requred to be serviced annually by a qualified servicing organiztion. Fire extinguishers were not current on servicing annually or monthly. Provide servicing report and show monthly log.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 19 March 2021
Resolution: Received documentary evidence (pictures) of servicing of the fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 March 2021 Resolved
Flares are required to be onboard the vessel and not expired. Flares are expired. Provide proof of new flares.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 19 March 2021
Resolution: Received documentary evidence (pictures) of new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2021 Resolved
Lifejackets are required to be labeled with the vessel's name. Label children life jackets with vessel name.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2021
Resolved 19 March 2021
Resolution: Received documentary evidence (pictures) of names affixed to the life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2021 Resolved
Fuel lines shall have cut off valves as to close against the fuel flow. Fuel hoses require double hose clamps. Fuel lines were not double clamped and one did not have any clamps.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 19 March 2021
Resolution: Received documentary evidence (pictures) of manual fuel disconnect and double hose clamps.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 March 2021 Resolved
Vessel is required to have current charts of navigable area, Tides and current table, and light list. Vessel didn't have current charts & tides and current table and light list was not on the vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 19 March 2021
Resolution: Received documentary evidence (pictures) of manuals and chart.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 March 2021 Resolved
Fire, abandon ship, & man overboard are required to be completed quarterly. Drills have not bveen logged since last annual Coast Guard inspection. Completed during exam.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 16 March 2021
Resolution: Vessel owner cleared deficiency while inspectors were onboard.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 16 March 2021 Resolved
Passenger count shall be communicated verbally or in writing and availabe at shore or with representative of vessel. Passenger count was only being logged on vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 19 March 2021
Resolution: Received documentary evidence (pictures) of dry erase board with current passenger count.
Navigation › Piloting/Steering › Marine Charts
Issued 23 February 2018 Resolved
Had old and not updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 28 March 2019
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 February 2018 Resolved
Update Light List and Coast Pilot
Condition: Invalid
Due 23 March 2018
Resolved 28 March 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2018 Resolved
Expired medicine
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 28 March 2019
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 10 January 2017 Resolved
Missing DAPI letter and supervisory training needed for vessel and both Captians.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 14 February 2017
Resolution: DAPi letter provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 January 2017 Resolved
Label life jacket stowage area for adult life jackets.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 14 February 2017
Resolution: Stowage was labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 December 2016 Resolved
Expired medical kit items, replace.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 14 February 2017
Resolution: New medicine provided for med kit.
Lifesaving › Hand Flares › Expired
Issued 23 February 2016 Resolved
Distress signals were expired/damaged
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 29 February 2016
Resolution: Vessel representative purchased new distress signals.
Lifesaving › Hand Flares › Storage
Issued 23 February 2016 Resolved
Distress signal container was not watertight.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 29 February 2016
Resolution: Vessel representative provided a watertight container.
Navigation › Piloting/Steering › Marine Charts
Issued 23 February 2016 Resolved
Vessel had no charts on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 14 March 2016
Resolution: Provided proper charts.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 February 2016 Resolved
Vessel had outdated light list/coast pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 29 February 2016
Resolution: Updated light list/coast pilot was provided.
Engineering › Bilge Water Management System › Not Operational
Issued 23 February 2016 Resolved
STBD submersible bilge pump float switch did not automatically activate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 29 February 2016
Resolution: Bilge pump wiring was corroded vessel representative replaced with new wiring.
Engineering › Fuel Oil Service System › Tank
Issued 25 January 2016 Resolved
Portable fuel tanks exceeded the 7 gallon capacity as per H-25 ABYC (current tanks are 26 gallons capacity each). Replace both portable fuel tanks in accordance with 46 CFR 182.458.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 February 2016
Resolved 23 February 2016
Resolution: Fuel tanks were replaced to meet the specified requirements.
Documentation › Markings/Placards › Lifejacket Placard
Issued 24 March 2014 Resolved
Place placard for adult lifejackets with the number of jackets on the container IAW 46 CFR 185.604(f).
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 April 2014
Resolution: Vessel CAPT used spray paint and stencils to permanently affix the number of adult lifejackets that were inside a container onboard the vessel.
Fire Fighting › Fire Bucket › Quantity
Issued 24 March 2014 Resolved
Replace two unserviceable fire buckets IAW 46 CFR 181.610
Action required: 705 - Other - as specified
Due 24 March 2014
Resolved 24 March 2014
Resolution: Vsl owner bought 3 new fire buckets meeting 46 CFR 181.610
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2014 Resolved
Replace expired items in first-aid kit IAW 46 CFR 184.710
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 April 2014
Resolution: Vessel Captain replaced expired items in first aid kit.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 24 March 2014 Resolved
Remount port engine fuel filter IAW 46 CFR 177.100
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 April 2014
Resolution: Port engine fuel filter was remounted and properly functioning.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 March 2014 Resolved
State registration number must be properly marked on the port side of the vessel IAW 46 CFR 67.123
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 April 2014
Resolution: State registration number was properly affixed to the port side of vessel.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 March 2014 Resolved
Provide current training records/logs to include fire, man overboard, and abandon ship IAW 46 CFR 185.524
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 April 2014
Resolution: Vsl Captain started new drill log and has completed first set of emergency drills. He is aware of his reponsiblity to conduct regular drills with crew and complete drills with any new crew members.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 15 September 2011 Resolved
Obtain proof of compliance with first aid/CPR training.
Due 26 October 2011
Resolved 19 October 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2010 Resolved
Prove operation of STBD running light & replace port running lights.
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 23 September 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2010 Resolved
Remove water and make watertight or Replace First Aid
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 23 September 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 September 2010 Resolved
Remove Water from Child life-jacket storage & make water / weather tight
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 23 September 2010
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 20 September 2010 Resolved
Replace or make serviceable life ring buoy.
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 23 September 2010
Engineering › Bilge Water Management System › Valve
Issued 20 November 2007 Resolved
Replace the overboard discharge valves from the bilge pump and the through hull penetrations as per 46 CFR 176.610.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2007
Resolved 28 November 2007
Resolution: Replaced the valves.
Engineering › Gasoline Engine (propulsion) › Ignition Wire (4 cycle)
Issued 20 November 2007 Resolved
Replace the throttle cable on the port outboard engine as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 20 December 2007
Resolved 28 November 2007
Resolution: Replaced the cable.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 November 2007 Resolved
Remove the deteriorated electrical junction box in the port and starboard aft compartments as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 20 December 2007
Resolved 28 November 2007
Resolution: Removed the boxes.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 11 July 2007 Resolved
Prove that the crew is certified in basic first aid and CPR as per NVIC 1-91.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 13 August 2007
Resolution: The crew is certified in basic CPR and first aid.
Documentation › Logs/Records › Logbook (official)
Issued 11 July 2007 Resolved
Provide a bridge log as per 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 13 August 2007
Resolution: A bridge log was provided.
Navigation › Piloting/Steering › Marine Charts
Issued 11 July 2007 Resolved
Provide a current navigation chart (11372), U.S. Coast Pilot [name withheld], and Tidal Current Tables as per 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 13 August 2007
Resolution: A new chart was provided with corrections.
Engineering › Fuel Oil Service System › Hose
Issued 11 July 2007 Resolved
Provide hose clamps for the fuel line as per 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 13 August 2007
Resolution: Hose clamps were installed on all fuel oil hose connection.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 July 2007 Resolved
Clean all lifejackets and spray for roaches in the lifejacket stowage area as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 13 August 2007
Resolution: The life jackets were cleaned.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 July 2007 Resolved
Make the lifejacket stowage area watertight as per 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 30 November 2007
Resolution: Welded a permanent knife edge around the containers. Added a gasket to the lids.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 July 2007 Resolved
Properly label the adult lifejacket with the vessel's name and replace the retro-reflective tape as per 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 28 November 2007
Resolution: Labeled the lifejacket.
Navigation › Piloting/Steering › Marine Charts
Issued 23 August 2006 Resolved
Provide current and corrected charts, an updated U.S. Coast Pilot, and a Coast Guard Light List in accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Provided current charts, coast pilot, and light list
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 August 2006 Resolved
Provide an emergency broadcast placard in accordance with 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Provided an emergency broadcast placard.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 August 2006 Resolved
Provide proper lifejacket donning placard for all lifejackets on board in accordance with 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Provided proper lifejacket donning placard
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 August 2006 Resolved
Provide the required amount of lifejackets in accordance with 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Replaced retro-reflective tape on 01 lifejacket.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 August 2006 Resolved
Provide proper separation of adult and child lifejackets in accordance with 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Separated the child and adult lifejackets
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 August 2006 Resolved
Provide an approved marine fire extinguisher bracket in accordance with 46 CFR 181.520.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Replaced fire extinguisher bracket for an approved marine type.
Fire Fighting › Fire Bucket › Lanyard
Issued 23 August 2006 Resolved
Attach a lanyard to fire buckets in accordance with 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Attached lanyards to the fire buckets.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 August 2006 Resolved
Prove proper operation of bilge pump alarm in accordance with 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Fixed broken port side bilge pump alarm
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 August 2006 Resolved
Properly secure wires and connections in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 23 September 2006
Resolved 15 September 2006
Resolution: Replaced improper electical junction box with an approved type.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2005 Resolved
Make repairs to hand rails in way of the broken welds and broken wood at the corners.
Due 12 January 2006
Resolved 10 March 2006
Resolution: Repairs to hand rails in way of the broken welds and broken wood at the corners were made with satisfactory results.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 August 2005 Resolved
Provide current tidal currents, light list and coast pilot as required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 21 November 2005
Resolution: All navigation publications were updated.
Fire Fighting › Fire Bucket › Quantity
Issued 8 August 2005 Resolved
Provide and place on board vessel, three fire buckets as required by 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 21 November 2005
Resolution: Fire buckets provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2005 Resolved
Provide aspirin for first aid kit as required by 46 CFR 184.170
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 21 November 2005
Resolution: Aspirin provided
Personnel › Training › First Aid/CPR
Issued 4 October 2004 Resolved
Provide proof of valid CPR/First Aid Training for 50% of crew IAW NVIC 1-91.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: Valid cards onboard
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 October 2004 Resolved
Provide tide and current tables IAW 46 CFR 184.420.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: Written as def 08AUG05
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 October 2004 Resolved
Renew eyewash in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: eye wash renewed
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 4 October 2004 Resolved
Provide two emergency portable lights IAW 46 CFR 183.430.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: Portable lights onboard
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 October 2004 Resolved
Provide two BII portable fire extinguishers IAW 46 CFR 176.810.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: All required extinguishers onboard
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 October 2004 Resolved
Post emergency instructions IAW 46 CFR 185.510.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: Instructions posted at operating station
Documentation › Markings/Placards › Warning Signs
Issued 4 October 2004 Resolved
Post "No Smoking" placard in vicinity of portable gasoline fuel tanks IAW MSM Ch 10.A.2.i.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 8 August 2005
Resolution: Sign posted
Electrical › Electrical Distribution System (service)
Issued 24 June 2002 Resolved
All electrical equipment and circuits must be clearly labeled & identified as required in 46CFR 183.220(d). LEGACY COMPONENT DESC: Panelboard
Due 3 July 2002
Resolved 3 July 2002
Electrical › Electrical Distribution System (service)
Issued 24 June 2002 Resolved
Bilge pumps and navigation lights must be energized from separate sources as require by 46 CFR 182.520(j); missing from electrical drawing. LEGACY COMPONENT DESC: Switch
Due 3 July 2002
Resolved 3 July 2002
Electrical › Electrical Distribution System (service)
Issued 24 June 2002 Resolved
Protect distribution panel from splashing water. LEGACY COMPONENT DESC: Distribution Panel Bus
Due 3 July 2002
Resolved 3 July 2002
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 June 2002 Resolved
Provide electrical drawing to show changes to Item #2.
Due 3 July 2002
Resolved 28 June 2002
Personnel › Certificates/Documents/Licenses
Issued 24 June 2002 Resolved
Provide license, CPR card and drug testing card. LEGACY COMPONENT DESC: License, Master
Due 3 July 2002
Resolved 3 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 24 June 2002 Resolved
Label children's lifejackets. LEGACY COMPONENT DESC: Marking
Due 3 July 2002
Resolved 3 July 2002
Navigation › Piloting/Steering
Issued 24 June 2002 Resolved
Provide ships bell. LEGACY COMPONENT DESC: Inland Navigation Rules
Due 3 July 2002
Resolved 3 July 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.