← All vessels
EMPIRE STATE
Offshore Supply Vessel · Offshore class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named EMPIRE STATE
EMPIRE STATE is a 2002 offshore supply vessel. The Coast Guard has recorded 27 inspections since 2002, most recently in December 2010, along with 88 deficiencies and 1 casualty investigation in 2007.
Records from 2002 to 2010. Most recent: inspection, 1 December 2010.
- Built
- 2002
- Last inspected
- 1 December 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 88 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2007
Identity
1128061
9271509 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB5740
567889
Flag
MARSHALL ISLANDS
369145000 (licence lapsed)
Maury page id
psix-567889
Inspections, by type
…with no type recorded1
Years with a record
9 calendar years (2002–2010)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it447 - Convention (Subpart B), Gross Ton
88 - Regulatory (Subpart C or D), Gross Ton
134 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
88 - Regulatory (Subpart C or D), Gross Ton
134 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDB5740MMSI 369145000 · cancelled · compulsorily equipped · granted 13 November 2003, cancelled 30 November 2010
WDA8553MMSI 369145000 · cancelled · compulsorily equipped · granted 1 June 2002, cancelled 8 January 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 27
1 December 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3902326
12 September 2010
Annual Inspection
Physical examination · Activities Europe · Activity 3846691
1 May 2009
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Activities Europe · Activity 3485064
22 August 2008
Deficiency Check
Physical examination · Activities Europe · Activity 3323846
24 April 2008
Annual Inspection
Physical examination · Activities Europe · Activity 3175969
13 December 2007
Hull Examination · Internal Structural Exam
Physical examination · Activities Europe · Activity 3121640
18 June 2007
COI Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 2955178
23 February 2007
Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 2867645
26 September 2006
Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2708974
30 May 2006
Administrative Inspection
Administrative · Activities Europe · Activity 2663892
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571499
4 January 2006
Hull Examination
Physical examination · Activities Europe · Activity 2539012
25 August 2005
Annual Inspection
Physical examination · Activities Europe · Activity 2457958
27 March 2005
Type not recorded
No type recorded · Activities Europe · Activity 2320549
3 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302975
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290146
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232633
26 June 2004
MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 2098809
3 June 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087664
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1967029
10 November 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1945054
22 October 2003
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1938498
18 June 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1827521
6 May 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1787760
18 April 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1776014
19 February 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1746356
10 June 2002
Inclining Experiment · COI Inspection · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1628709
Deficiency record · 88
Communications › Radio Communications › Satellite Communications Capability
Issued 12 September 2010
Resolved
Due to damage caused by lightning strike, and noted failures with GMDSS suite, SOLAS Safety Radio Cert is considered invalide. ABS to conduct damage and/or renewal survey to ensure proper operation and that Certificate is valid.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 12 September 2010
Resolved
Trouble shoot and ensure fire alarm panel readout correlates properly with area and zone affected and allows operator to know where alarm has been activated, prior to sailing,
Lifesaving › Launching Appliances › Falls
Issued 12 September 2010
Resolved
Provdie proof that wire rope for rescue boat davit has either been end-for-ended or renewed within 30 days.
Lifesaving › Launching Appliances › Release Mechanism
Issued 12 September 2010
Resolved
Provide proof rescue boat hook is CG approved or replace with CG approved hook within 30 days.
Lifesaving › Inflatable Liferafts › Servicing
Issued 12 September 2010
Resolved
Annual inflatable liferaft service is extended 14 days for all liferafts onboard. Provide service documentation for aliferafts within 14 days.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 September 2010
Resolved
Provide fire servicing test report for fixed systems (witnessed by CG onboard) and portable extinguishers within 30 days.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 12 September 2010
Resolved
Engine Room rudder angle indicator inoperative (emergency steering station). Troubleshoot and repair within 30 days.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 12 September 2010
Resolved
Obtain USCG approved rescue boat searchlight within 30 days. (extended to 60 days)
Lifesaving › Rescue Boat › Construction
Issued 12 September 2010
Resolved
Obtain Zodiac H380 Safety Alert 0603 and implement service technical bulletins to address hazards of forward lifting point failures (or prove that they have been implemented--no record onboard) within 30 days. Do not launch or lift rescue boat with personnel embarked until corrected. Extended 1 month.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 22 August 2008
Resolved
Prove proper operation of the vessel's fixed fire fighting time delays of the engineroom and bow thruster space.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 22 August 2008
Resolved
Provide two SCBA bottles with current hydrostatic test dates.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 August 2008
Resolved
Properly supply first aid kits for the vessel.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 22 August 2008
Resolved
Provide satisfactory evidence of annual pressure testing of fuel hoses.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 August 2008
Resolved
Provide satisfactory evidence that the OWS discharge effluent meets MARPOL 73/78 discharge requirement of 15 ppm.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 August 2008
Resolved
Obtain blood alcohol content (BAC) detection equipment for determination of intoxication iaw 46CFR4/46CFR16/33CFR95.
Cleared via email from company to be cleared during next inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 22 August 2008
Resolved
Install fire extinguishing system, flame screens, and ventilation closures for portable paint locker.
Cleared via email from company to be cleared during next inspection.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 August 2008
Resolved
Provide EPIRB registration.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 22 August 2008
Resolved
Provide all gear for vessel's fire suits including hood, lifeline, ax, and hand lantern (high visibility flash lights with minimum burning period of three hours),
Lifesaving › Rescue Boat › Carriage Requirement
Issued 22 August 2008
Resolved
Provide all required equipment for vessel's rescue boat.
Cleared via email from company to be cleared during next inspection.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 August 2008
Resolved
Demonstrate proper operation of the windshield wiper on the aft station on the bridge.
Cleared via email from company to be cleared during next inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 August 2008
Resolved
Have portable fire extinguishers requiring hydrotesting properly hydrotested at a DOT approved facility. At all times vessel to have onboard minimum number of extinguishers required by COI and described by fire control plan.
Cleared via email from company to be cleared during next inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2008
Resolved
Remove dead-ended electrical wiring iwo deck house, aft stbd side.
Cleared via email from company to be cleared during next inspection.
Fire Fighting › Fire Hoses › Connections
Issued 22 August 2008
Resolved
Obtain spanner wrench for #2 fire station.
Cleared via email from company to be cleared during next inspection.
Lifesaving › Lifebuoys › Serviceable
Issued 22 August 2008
Resolved
Renew #1 lifebuoy.
Cleared via email from company to be cleared during next inspection.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 22 August 2008
Resolved
Remove non-flammable/non-combustible materials from the permanent paint locker which prevents the proper utilization of the paint locker.
Cleared via email from company to be cleared during next inspection.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 22 August 2008
Resolved
Owner/operator shall conduct an internal audit of the vessel using the SMS, and provide a written report of the internal audit to USCG Activities Europe. During the audit special emphasis shall be placed on compliance with relevant navigation equipment, general health and safety, structural integrity, ground tackle, lifesaving equipment, fire protection, pollution
prevention and machinery.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 August 2008
Resolved
Demonstrate proper operation of the sewage air pump.
Cleared via email from company to be cleared during next inspection.
Lifesaving › Launching Appliances › Falls
Issued 24 April 2008
Resolved
REPLACE RESCUE BOAT FALLS AND CONDUCT LOAD TEST.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 24 April 2008
Resolved
REPLACE MISSING EYEWASH BOTTLES NEAR ELECTRONICS SPACE.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 April 2008
Resolved
CONDUCT PROPER SERVICING OF THE FIXED FIRE FIGHTING SYSTEMS IN THE PRESENCE OF A USCG MARINE INSPECTOR
Lifesaving › Inflatable Liferafts › Servicing
Issued 13 December 2007
Resolved
All liferafts are to be serviced no later than 01 July 2008. If liferafts are inspected at SODIP in Douala, Cameroon, the inspection must be completed in the presence of a USCG Marine Inspector.
Communications › Alarms/Indicators › Fire Alarm
Issued 18 June 2007
Resolved
Demonstrate the operation of the fire detection and alarm system, to include the Ansul Autopulse IQ-301 panel, manual pull alarms and smoke detectors. Cleared by e-mail dated June 23, 2007. Extended compliance date so next attending inspectors can verify compliance.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 18 June 2007
Resolved
Provide a marine grade compass for the rescue boat. This item was also reported as deficient and corrected from the September 26, 2006 examination.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 June 2007
Resolved
Replace the cable for hand lowering the rescue boat.
Communications › Alarms/Indicators › Fire Alarm
Issued 18 June 2007
Resolved
Repair or replace the galley smoke detector. Cleared by e-mail dated June 23, 2007. Extended compliance date so next attending inspectors can verify compliance.
Lifesaving › Rescue Boat › Stability
Issued 18 June 2007
Resolved
Inflate the rescue boat pontoons to manufacturer’s specifications.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 18 June 2007
Resolved
Service and/or repair the rescue boat’s outboard motor.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 June 2007
Resolved
Repair or replace the rudder room bilge alarm.
Communications › Radio Communications › Emergency Source of Power
Issued 18 June 2007
Resolved
Demonstrate the operation of the GMDSS under battery power. Cleared by e-mail dated June 23, 2007. Extended compliance date so next attending inspectors can verify compliance.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 June 2007
Resolved
Replace the extinguished emergency light bulb in the aft engine room.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 June 2007
Resolved
Clean the lamps of all three engine room emergency lights.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 June 2007
Resolved
Demonstrate the proper operation of the oily water separator oil content sensor and pump shut-down. Cleared by e-mail dated June 23, 2007. Extended compliance date so next attending inspectors can verify compliance.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 18 June 2007
Resolved
Provision the rescue boat in accordance with 46 CFR 133.175(a) and (b). Items denoted in Table 133.175 were missing; few were actually stowed in the rescue boat.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 18 June 2007
Resolved
Provide a full tank of gasoline for the rescue boat.
Documentation › Logs/Records › Oil Record Book
Issued 18 June 2007
Resolved
Train the [name withheld] in the proper recording of Oil Record Book entries. A review of the Oil Record Book revealed that the Chief Engineer was not recording waste oil levels weekly (C.11.1), bunkering recorded under paragraph H were incomplete in that tanks and type of fuel were missing (H.27.3), letter codes were missing from some entries.
Communications › Radio Communications › EPIRB
Issued 23 February 2007
Resolved
Provide approved epirb prior to getting underway.
Stability › Watertight Integrity › General
Issued 23 February 2007
Resolved
Remove doubler plate on Starboard side of vessel and properly insert affected area.
Engineering › Fuel Oil Service System › Tank
Issued 23 February 2007
Resolved
Properly repair holed area in #3 fuel tank..
Stability › Watertight Integrity › General
Issued 23 February 2007
Resolved
Provide proof of proper installation of all inserts conducted during drydock period.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 23 February 2007
Resolved
Provide proof of proper installation and blueing test demonstrating 80% contact with the shaft.
Construction/Loadline › Hull › Bottom Plating
Issued 23 February 2007
Resolved
Properly insert area affected by excessive clad weld in way of the Starboard Generator Keel cooler as per company proposal. The affected area is between frames 39 to 33, approximately 22 in X 18 ft, to be completed to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Inflatable Liferafts › Float Free
Issued 23 February 2007
Resolved
Properly install liferafts for manual launching as well as float free configuration.
Lifesaving › Launching Appliances › Davit
Issued 26 September 2006
Resolved
Make repair to broken rescue davit sheave. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Lifesaving › Rescue Boat Equipment › Binnacle/Compass
Issued 26 September 2006
Resolved
Provide a compass for the rescue boat. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Lifesaving › Launching Appliances › Falls
Issued 26 September 2006
Resolved
Provide documentation of the rescue boat falls; end for end and renewal dates. If documentation cannot be provided, falls must be renewed. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 September 2006
Resolved
Make repairs to fire detection system: locate and eliminate ground fault. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 September 2006
Resolved
Review the fire & safety plan for accuracy & make correction, in accordance with 46CFR131.945. Fire extinguishers & ring life buoy lights are incorrectly marked. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Communications › Radio Communications › EPIRB
Issued 26 September 2006
Resolved
Replace deteriorated antenna on EPIRB with a new antenna. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 September 2006
Resolved
Provide documentation of enrollment in a drug & alcohol testing program & pre-employment testing for the following crewmembers:
a. N'Guila, Leon
b. Alphonse, Koumba
c. Kokolo, Jean
d. Sockath, Louis
e. Moufouma, Albert
28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 September 2006
Resolved
Provide corrosion proof clips on lines connection waterlights to ring life buoys. 28NOV06: Rcvd email from the port captain. Item is cleared. Extended due date to correspond with COI due date, so the next inspector can verify.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 September 2006
Resolved
Provide documentation that the fixed fire extinguishers have been properly weighed. Liquid level gauging is no longer authorized.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 September 2006
Resolved
Remove or properly secure the excess storage in the steering gear compartment.
Engineering › Lubricating Oil Service System › Valve
Issued 26 September 2006
Resolved
Prove proper operation of port inboard main engine lube oil shutdown valve.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 26 September 2006
Resolved
Replace plastic fuel fill caps with proper metal caps.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 26 September 2006
Resolved
Provide proper labeling and exercise the deck emergency fuel shut offs.
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2006
Resolved
Provide gauging report of stern shaft area
Construction/Loadline › Hull › Collision Chock
Issued 4 January 2006
Resolved
Provide gauging report of cutl;ass bearings
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Blower, Centrifugal
Issued 4 January 2006
Resolved
C/E is to provide statement that stbd generator exhaust fan has been cleaned and replaced
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2006
Resolved
Provide diagram of are a to be cropped and renewed
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2006
Resolved
All plate renewal to be completed under ABS or USCG oversight
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 25 August 2005
Resolved
Properly mark loadline marking in accordance with International Load Line Certificate. Cleared by e-mail from the master [name withheld] #89533 on 10/12/2005. Verify at next attendance.
Lifesaving › Rescue Boat Equipment › Binnacle/Compass
Issued 25 August 2005
Resolved
Replace missing rescue boat equipment i.e. compass, radar reflectors, sea anchor, search light, and thermal protective aids.
Cleared by e-mail from the master [name withheld], #89533 on 11/08/2005. Verify at next attendance.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 August 2005
Resolved
Re-adjust the following watertight doors: forward engine room door and forward machinery space prior to departure from port.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 August 2005
Resolved
Repair exhaust leaks on all four main diesel engines. Extended due date until the next drydock date.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 26 June 2004
Resolved
Provide means to test and demonstrate over speed shut down for main engines (X4). Cleared via fax; verify at next USCG attendance.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 26 June 2004
Resolved
Provide means to test and demonstrate over speed shut down for generator engines (X2). Cleared via fax; verify at next USCG attendance.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 26 June 2004
Resolved
Provide means to test and demonstrate low lube oil shut down for main engines (X4). Cleared via fax; verify at next USCG attendance.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 June 2004
Resolved
Provide means to test and demonstrate low lube oil shut down for generator engines (X2). Cleared via fax; verify at next USCG attendance.
Lifesaving › Inflatable Liferafts › Markings
Issued 26 June 2004
Resolved
Provide liferaft launching instructions in the way of liferaft station. Cleared via fax; verify at next USCG attendance.
Lifesaving › Line-Throwing Appliances
Issued 10 November 2003
Resolved
Properly label line-throwing gun. LEGACY COMPONENT DESC: Labeling
Accommodation/Occupational Safety › Potable Water System
Issued 10 November 2003
Resolved
Provide bug screens for main deck potable water tanks. LEGACY COMPONENT DESC: Vents Provide
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 November 2003
Resolved
Renew eye wash bottles.
Documentation › Markings/Placards
Issued 10 November 2003
Resolved
Properly label all lifejacket stowage areas. LEGACY COMPONENT DESC: Lifejacket stowage
Fire Fighting › Fire Main
Issued 10 November 2003
Resolved
Provide accurate fire main gage for fire main system at pilothouse console. LEGACY COMPONENT DESC: Gage
Documentation › Certificates/Documents
Issued 10 November 2003
Resolved
Provide annual SOPEP review letter. LEGACY COMPONENT DESC: Annual SOPEP Letter
Construction/Loadline
Issued 10 June 2002
Resolved
PROVIDE APPROVED PROPULSION CONTROL PLANS. LEGACY COMPONENT DESC: PLANS
Construction/Loadline
Issued 10 June 2002
Resolved
PROVIDE APPROVED FIRE MONITOR HYDRAULIC CONTROL SYSTEM PLANS. LEGACY COMPONENT DESC: PLANS
Construction/Loadline
Issued 10 June 2002
Resolved
PROVIDE APPROVED ELECTRICAL LOAD ANALYSIS. LEGACY COMPONENT DESC: PLANS
Casualty record · 1
4 August 2007Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 dead · activity 3029506
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.