Records from 2002 to 2026. Most recent: inspection, 20 January 2026.
Inspection history · 50
20 January 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8298436
24 November 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8273490
6 October 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8246904
15 June 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8156346
4 June 2025
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8152582
26 August 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7986084
29 January 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7857121
23 October 2023
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7811747
15 May 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7685326
11 May 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7685890
13 April 2023
Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7667762
14 October 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7577520
30 August 2022
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7545142
18 May 2022
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7447672
6 August 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7279088
5 April 2021
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7168569
4 April 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7169150
31 March 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7165653
27 July 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7017707
29 June 2020
Ballast Water Examination · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6983719
10 June 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6972915
13 May 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6952835
30 April 2020
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6946594
11 March 2019
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6638144
14 August 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6506809
31 January 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6347002
26 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6344360
8 September 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6262476
23 August 2017
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6248847
8 May 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6141102
16 January 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6067916
10 November 2015
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5757868
20 October 2014
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5008334
4 December 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3904072
20 September 2010
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3853558
10 June 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3227248
5 November 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3096095
8 February 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2868843
5 June 2006
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2670454
19 October 2005
MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2517440
11 February 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2291056
9 November 2004
PII Safety Exam · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2237102
25 July 2004
ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2141848
21 May 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2073972
26 March 2004
Ballast Water Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2031605
24 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2030178
17 September 2003
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1907164
1 April 2003
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 1805741
12 December 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1714818
21 May 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1619101
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 20 January 2026
Resolved
EACH INCINERATOR SUBJECT TO THIS SUBPARAGRAPH SHALL BE APPROVED BY THE ADMINISTRATION TAKING INTO ACCOUNT THE STAND SPECIFICATION FOR SHIPBOARD INCINERATOR DEVELOPED BY THE ORGANIZATION. THE MATERIALS USED IN THE INDIVIDUAL PARTS OF THE INCINERATOR ARE TO BE SUITABLE FOR THE INTENDED APPLICATION WITH RESPECT TO HEAT RESISTANCE, MECHANICAL PROPERTIES, OXIDATION, CORROSION, ETC. PSCO OBSERVED DETERMINED FIRE BRICK IN THE INCINERATOR.
MARPOL VI 16.6.1 - RESOLUTION MEPC 244(66)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 31 January 2026
Resolution: PSCDO RCVD CLASS (KR) REPORT OF PROPER REPAIRS & TESTING (SEE DOCS), CLEARED DEF.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2025
Resolved
The fixed fire detection system shall be capable of rapidly detecting the onset of fire. PSCO observed electrical tape wrapped around 04 smoke detectors throughout the cargo holds. The tape was situated in such a way as to inhibit the normal operation of the detectors.
74 SOLAS (01) II/2/37.1.4.1
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 21 June 2025
Resolution: Class report received. Rectified by ship's staff and verified by attending surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 June 2025
Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosions in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. PSCO observed numerous explosion proof lights with missing and damaged glands, compromising the integrity of the fixture.
74 SOLAS (04) II/1/45.5.4
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 June 2025
Resolved 6 October 2025
Resolution: Recieved class report attesting to proper repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 15 June 2025
Resolved
The machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. PSCO observed three auxiliary generators with openings in the flywheel covers big enough for a hand, presenting a safety risk to personnel.
74 SOLAS (04) II-1/26.1
40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2025
Resolution: Recieved class report attesting to proper repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 June 2025
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed the load line markings not painted in contrasting colors.
ICLL 8
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2025
Resolution: Recieved class report attesting to proper repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 April 2023
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed oil flowing over the turbo #1 of the main engine.
SOLAS (1997) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 April 2023
Resolved 14 April 2023
Resolution: Received Class Report clearing the deficiency.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 30 August 2022
Resolved
General arrangement plans shall be showing clearly the various fire sections enclosed by "A" class, "B" class divisions. 02 doors to the engine control room and the double doors leading to the workshop do not match current fire control plan. double doors are shown on the fire plan to be self closing "A" class but have no fire rating and do not self close. Doors to engine control room are shown as "A" class self closing but vessel does not have documentation showing fire rating. 74SOLAS(09) II-2/15.2.4.1
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 October 2022
Resolution: Received class report of the rectification of the correction of the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2021
Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. Vessel experianced a loss of controlof astern propulsion when mooring up in charleston.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: Recieved Class Report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 March 2021
Resolved
The fire resistance of doors shall be equivalent to that of the division in in which they are fitted. The class "A" fire door in aft steering was damaged to the point of not closing properly, compromising the fire integrity of the space.
74 SOLAS (04 Cons.) II-2/9.4.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 August 2021
Resolution: Received class report and photos of the new A-0 door installed for the steering room.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 March 2021
Resolved
Each liferaft or group of liferafts shall be stowed with a float free arrangement complying with the requirements of paragraph 4.1.6 of the code...PSCOs observed port and starboard side rafts secured to the deck, not in a float free arrangement
Action required: 10 - Deficiency Rectified
Resolved 31 March 2021
Resolution: Liferafts were placed in a float free arrangement prior to PSCO leaving the vessel
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 June 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regualitons to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Excessive oil was found pooling around main engine due to leaking gasket on fuel pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 27 July 2020
Resolution: recieved class report attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 April 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. During docking evolution, the vessel allided with Dock 122 causing damage to the vessel's starboard side. Provide survey report from vessel classification society attesting to the continued seaworthiness of the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2020
Resolution: Class attended and issued survey report requiring damage to be repaired by 31JUL20. See attached.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 23 August 2017
Resolved
I.A.W LSA CODE 4.6.2.9 The handrail mount to the starboard lifeboat was not secure to the lifeboat due to excessive wastage around the mount. 74 SOLAS(14) III/34 LSA CODE 4.6.2.9
Action required: 705 - Other - as specified
Due 23 September 2017
Resolved 29 September 2017
Resolution: Received Class Survey and service report atesting to proper repairs being made to the lifeboat railing.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 10 June 2008
Resolved
The second officer (2/O) has a GMDSS certificate issued 19 November 2007 by the republic of the Philippines, that has not been endorsed by panama. 2nd/0ff is in excess of the minimum requirements of the minimum safe manning certificate. (STCW I/4, I/10, I/14)
Action required: 705 - Other - as specified
Due 10 July 2008
Resolved 11 June 2008
Resolution: Received copy of ROA from Panama. Original certificate is to meet ship in Panama
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 10 June 2008
Resolved
The second assistant engineer’s Philippines certificate of competency (E3-0041172), Has not been endorsed by Panama, crew member is in excess of the requirements of the minimum safe manning certificate. Crewmember cannot stand watch until he has proper Panama endorsement. (STCW I/4, I/10, I/14)
To the satisfactionof the administration.
Action required: 15 - Rectify deficiencies by next port
Resolved 11 June 2008
Resolution: Received copy of ROA from Panama. Original certificate is to meet ship in Panama
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 8 February 2007
Resolved
Emergency fire pump leaks excessive amounts of water while operating due to eroded bolts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 8 February 2007
Resolution: Bolts were replaced on the spot and deficiency was rectified to the satisfaction of the attending flag surveyor and Coast Guard inspectors.
Lifesaving › Launching Appliances › Falls
Issued 8 February 2007
Resolved
Portside davit-launched lifeboat has damaged falls due to previous operational mishap. Falls are badly frayed in one portion. Repair/replace to satisfaction of flag administration.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 8 February 2007
Resolution: Attend flag surveyor inspected the falls while Coast Guard inspectors were on board. Surveyor recommended to remove the frayed section of the falls, refit the existing falls, and to have the entire falls replaced on 11FEB2007 in Jacksonville, FL.
Deck/Cargo › Cargo Stowage › General
Issued 19 October 2005
Resolved
Ship is securing vehicles by lashing to wheels. Cargo Securing Plan does not show or mention this as an acceptable arrangement. By 19NOV05, ship to have Managers and Class review Appendix 4 of Cargo Securing Manual to show how all vehicles/trucks should be properly lashed.
Due 19 November 2005
Resolved 5 June 2006
Resolution: Reviewed class approved portions of the cargo securing manual (lashing guide) for vehicles. Vessel securing vehichles in accordance with Cargo Securing Plan.
Fire Fighting › Fixed Deck Foam System
Issued 26 March 2004
Resolved
FIRE FIGHTING FOAM TANK LOCATED STBD SIDE STEERING GEAR RIIM IS FRACTURED AND LEAKING. REPAIR TO THE SATISACTION OF CLASS SOCIETY SURVEYOR LEGACY COMPONENT DESC: TANK
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 22 April 2004
Resolution: Received Class report attesting to the proper repair and integrity of the foam tank.