Records from 2002 to 2021. Most recent: inspection, 8 June 2021.
Inspection history · 25
8 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7229122
8 November 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6037741
21 July 2015
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5191738
21 May 2014
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4865407
19 March 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4818380
29 May 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4321928
28 July 2011
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4137557
24 July 2011
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4093473
4 January 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3920467
29 March 2010
COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3704563
30 July 2008
Type not recorded
No type recorded · USCGC HAMMERHEAD (WPB 87302) · USCG Northeast District (CGD-NE) · Activity 3284773
30 July 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3285330
12 July 2008
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3310940
12 June 2008
COI Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3234792
23 May 2007
COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2938846
21 June 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2687221
24 May 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2657732
2 September 2004
MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2183998
29 August 2004
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2180119
7 August 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2246196
20 May 2004
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2073780
30 October 2002
Deficiency Check · In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1698245
7 August 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1658091
4 August 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1668953
22 May 2002
Plan Review "T" Boat · Hull Examination · Simplified Stability Test · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1619719
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 May 2014
Resolved
Vessel to submit a repair proposal for spongy deck iwo engine room hatches. Plan received and approved on 22MAY2014. Will verify repair after completion.
Action required: 705 - Other - as specified
Resolved 12 June 2014
Resolution: Repair proposal was approved on 22MAY2014. Repair complete on 12JUN2014.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 20 April 2010
Resolved
Missing required B-II for Machinery Space
Action required: 705 - Other - as specified
Resolved 23 April 2010
Resolution: Recieved reciept of purchase for new extinguisher.
Fire Fighting › Fire Bucket › Availability
Issued 19 June 2008
Resolved
Provide 3 fire buckets with lanyards that meet the requirements of 46 CFR 181.610. Vessel is restricted from carrying passengers until the fire buckets are placed on board and available for immediate use.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2008
Resolved 25 June 2008
Communications › Radio Communications › EPIRB
Issued 19 June 2008
Resolved
Provide validation sticker IWO 406 Mhz, Category I EPIRB. Vessel is restricted to no more than three miles from shore.
Due 19 July 2008
Resolved 11 July 2008
Resolution: Vessel Representative submitted email with photograph documenting he received the EPIRB registration sticker.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 June 2008
Resolved
Make necessary repairs to the bilge high level alarm at the operating station on the main deck. All visual alarms are currently energizing for all spaces when only one space is tested.
Due 19 July 2008
Resolved 1 July 2008
Lifesaving › Visual Distress Signals (General) › Marking
Issued 12 June 2008
Resolved
Properly mark watertight container with the words "Distress Signals" in accordance with 46 CFR 185.614.
Due 19 July 2008
Resolved 19 June 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2007
Resolved
Prove proper operation of audible high water alarm for forepeak.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 23 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2007
Resolved
Label high water alarms.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 19 June 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 May 2007
Resolved
Provide original/valid Certificate of Documentation onboard vessel.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 9 July 2007
Construction/Loadline › Structures › Scupper
Issued 23 May 2007
Resolved
Provide captive chain in way of bow hatch.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 19 June 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 23 May 2007
Resolved
Provide smoke detector for forward accomodation space.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 19 June 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 June 2006
Resolved
Remove fuel from engine room bilge and properly dispose.
Condition: Improper/Lack of Maintenance
Due 30 June 2006
Resolved 21 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2006
Resolved
Change bulbs in all inoperable engine room light fixtures.
Condition: Improper/Lack of Maintenance
Due 30 June 2006
Resolved 26 September 2006
Resolution: Cleared via fax.
Stability › Watertight Integrity › General
Issued 21 June 2006
Resolved
Properly cap starboard spare through-hull fitting valve.
Condition: Placed in Improper Service
Due 30 June 2006
Resolved 26 September 2006
Resolution: Cleared via fax.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 24 May 2006
Resolved
Properly install aft fuel oil tank vent hoses.
Condition: Improper Installation
Due 30 June 2006
Resolved 22 June 2006
Construction/Loadline › Hull › Girder
Issued 24 May 2006
Resolved
Repair third frame from the transom using a sister frame. Frame is cracked approximately 6 inches from bottom.
Condition: Unknown
Due 30 June 2006
Resolved 22 June 2006
Stability › Freeing Ports › General
Issued 24 May 2006
Resolved
Remove metal plate installed in way of the freeing ports. Veesel does not meet freeing port requirements with the covers installed.
Condition: Improper Installation
Due 30 June 2006
Resolved 22 June 2006
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 24 May 2006
Resolved
Properly install bonding straps from the battery bank in engineroom to the common strap.
Condition: Improper Installation
Due 30 June 2006
Resolved 22 June 2006
Engineering › Bilge Water Management System › Piping
Issued 2 September 2004
Resolved
Electric bilge pump hose in E/R missing a secondary clamp.
Condition: Unknown
Due 15 September 2004
Resolved 10 September 2004
Resolution: Secondary clamps installed.
Communications › Radio Communications › EPIRB
Issued 2 September 2004
Resolved
EPIRB static release system (Expired-April 2004).
Due 15 September 2004
Resolved 10 September 2004
Resolution: Renewed static release system.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 2 September 2004
Resolved
VDS (Expired-March 2004).
Due 15 September 2004
Resolved 10 September 2004
Resolution: VDS renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 September 2004
Resolved
Lighting fixture (decklight) in pilot house fwd/star. side needs to be repaired/replaced.
Condition: Improper/Lack of Maintenance
Due 15 September 2004
Resolved 10 September 2004
Resolution: Fixtures repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 September 2004
Resolved
Lighting fixture (deckhouse) fwd/port side bulb needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 15 September 2004
Resolved 10 September 2004
Resolution: Fixtures repaired.
Construction/Loadline › Structures › Superstructure
Issued 2 September 2004
Resolved
Ladder leading to pilot house has loose rubber foot grips.
Condition: Placed in Improper Service
Due 15 September 2004
Resolved 10 September 2004
Resolution: Foot grip hardware renewed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 May 2004
Resolved
Properly install toilet discharge pipe to marine sanitation device. Secure access to head until corrected.
Due 20 May 2004
Resolved 2 September 2004
Resolution: Toilet piping properly reinstalled.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 20 May 2004
Resolved
Vessel missed 2003 Annual inspection. Vessel restricted from carrying passengers until satisfactory completion of Annual inspection. LEGACY COMPONENT DESC: Missed required annual inspection
Due 20 May 2004
Resolved 2 September 2004
Resolution: Conducted Annual COI Examination.
Documentation › Certificates/Documents
Issued 30 October 2002
Resolved
Provide copies of COD and Drug Consortium to USCG
Due 12 November 2002
Resolved 7 November 2002
Resolution: Proved to have valid certificates.
Documentation › Certificates/Documents
Issued 30 October 2002
Resolved
Post Stability Letter in wheelhouse LEGACY COMPONENT DESC: Stability Letter
Due 12 November 2002
Resolved 27 December 2002
Resolution: Stability letter posted.
Operations/Management › Equipment Service/Testing
Issued 30 October 2002
Resolved
Prove use of logbook with entries for operations, training, and lifesaving equipment maintenance.
Due 12 November 2002
Resolved 27 December 2002
Resolution: Examined logbook to find entries for last two trips.
Operations/Management › Passenger Operations
Issued 30 October 2002
Resolved
Provide means for leaving passenger count ashore for each trip.
Due 12 November 2002
Resolved 27 December 2002
Resolution: Waterproof box left at the pier with vessels name. Operator will leave passenger count and date in the box before departing on each trip.
Documentation › Manifests/Lists
Issued 30 October 2002
Resolved
Post Emergency Instructions LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Due 12 November 2002
Resolved 27 December 2002
Resolution: Emergency instructions were posted.
Navigation › Piloting/Steering
Issued 30 October 2002
Resolved
Obtain copies of Light List and Tides and Currents LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 12 November 2002
Resolved 27 December 2002
Resolution: Most current pubs currently onboard.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2002
Resolved
Mark upper deck with "No Passengers"
Due 12 November 2002
Resolved 27 December 2002
Resolution: Upper deck marked with large signed stating "CREW ONLY"
Lifesaving
Issued 22 May 2002
Resolved
Properly register and install a 406Mhz EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2002
Operations/Management › Lifesaving
Issued 22 May 2002
Resolved
Provide First Aid Kit complying with 160.041
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2002
Stability › Incline Test › General
Issued 22 May 2002
Resolved
No passengers may be carried on the upper deck until rail requirements are met in accordance with 46 CFR Part 177.900. Vessel stability is satisfactory for 13 total persons on the upper deck when this requirement has been met. LEGACY COMPONENT DESC: Passengers on upper deck
Action required: 705 - Other - as specified
Resolved 22 June 2006