Records from 2002 to 2026. Most recent: inspection, 12 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
12 June 2026
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8394800
24 June 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8158499
22 April 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8115828
27 June 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7936773
21 June 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7715060
21 April 2023
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7671858
6 June 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7467611
19 July 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7261078
20 April 2021
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7179005
9 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6972996
14 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6709615
2 May 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6675011
15 June 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6443845
9 June 2017
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6169694
20 April 2017
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6128969
27 May 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5888157
5 June 2012
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4333853
13 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207290
9 March 2009
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3430170
21 May 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3212935
24 April 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3191184
11 May 2007
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2927543
20 March 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2891075
5 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2670466
6 June 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2381213
6 May 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2350630
1 June 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2085120
9 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1812889
17 March 2003
Hull Examination · Internal Structural Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1758871
17 June 2002
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1630529
9 May 2002
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1626124
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10.
46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 27 June 2024
Resolved 27 June 2024
Resolution: Rectified on the spot with the Owner/Operator.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 June 2024
Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Owner/Operator was not documenting passenger count, must provide CG with a plan/procedure for documenting passenger count.
46 CFR 185.504
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 27 June 2024
Resolution: Vsl operator provided plan for electronic tracking of passenger count.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2021
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050, The life buoy was missing the required grab lines.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 19 July 2021
Resolution: Yacht club manager submitted photo of new life buoy, with correct markings.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2021
Resolved
The operator must provide satisfactory evidence of the required servicing for portable fire extinguishers to the marine inspector. The fire extinguisher 10-B:C did not have a record of annual servicing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 19 July 2021
Resolution: Yacht club manager submitted photo of new 10-B:C portable fire extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 June 2020
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed. No valve installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 3 July 2020
Resolution: Positive shutoff valve installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2019
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon fire buckets. Provide required fire buckets. 46CFR181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: Fire buckets provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2019
Resolved
A vessel must be provided with an auxiliary means of steering. Provide an auxiliary means of steering. 46CFR182.620
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: Auxiliary means of steering provided.
Engineering › Gas Turbine (propulsion-reduction gear) › Delivery Air Manifold
Issued 15 June 2018
Resolved
Install means to secure engine air intake.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2018
Resolved 26 June 2018
Resolution: Installed means to secure engine air intake.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 June 2018
Resolved
Replace expired items in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2018
Resolved 26 June 2018
Resolution: Replaced expired items in the first aid kit.
Engineering › Bilge Water Management System › Piping
Issued 15 June 2018
Resolved
Replace hose on the portable water pump.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2018
Resolved 26 June 2018
Resolution: Replaced hose on the portable water pump.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 20 April 2017
Resolved
Replace worn cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 26 April 2017
Resolution: Satisfactorily examined new cutlass bearing.
Engineering › Fuel Oil Service System › Filter
Issued 27 May 2016
Resolved
ST01- Provide flame impingement bowl for fuel filter in engine compartment.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 20 April 2017
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. TO VERIFY COMPLIANCE, A STABILITY TEST MUST BE COMPLETED. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THERFORE LIMITED TO: 21 PERSONS(PASSENGERS AND CREW)
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 24 April 2012
Resolution: At owner''s request, conducted weight ratio calculations based upon sister vessel GRAYLING.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 5 June 2006
Resolved
Provide fixed firefighting servicing report.
Due 19 June 2006
Resolved 5 June 2006
Resolution: Provided sat.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 9 June 2003
Resolved
Complete annual service on fixed and portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2003
Operations/Management › Drills/Instruction
Issued 9 May 2002
Resolved
Preform drills to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002
Resolution: Witnessed drills.
Operations/Management › Drills/Instruction
Issued 9 May 2002
Resolved
Provide a training log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002
Operations/Management › Drug and Alcohol Testing
Issued 9 May 2002
Resolved
Provide verification of enrollment in a Drug and Alcohol Monitoring Program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002
Documentation › Certificates/Documents
Issued 9 May 2002
Resolved
Complete new to zone COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002
Documentation › Certificates/Documents
Issued 9 May 2002
Resolved
Provide proof of radio station license.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002
Documentation
Issued 9 May 2002
Resolved
Provide proof of servicing and testing of FFF system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2002