WAN HAI 612

WAN HAI 612 is a 2001 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in July 2023, along with 11 deficiencies and 4 operational controls.

Records from 2016 to 2023. Most recent: operational control imposed, 15 July 2023.

Built
2001
Last inspected
15 July 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9224518
9V3465
568330
Flag
SINGAPORE
Maury page id
psix-568330

Documentation record

Tonnage as PSIX records it25395 - Convention (Subpart B), Net Ton
71395 - Dead Weight, Metric Ton
95895 - Displacement, Metric Ton
68687 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

10 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

15 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742982
13 June 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7713788
29 April 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7676597
26 April 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7674657
20 June 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7471651
7 March 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7407482
14 February 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7396188
18 December 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7370044
8 December 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364995
9 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812292

Deficiency record · 11

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 26 April 2023 Resolved
The ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that the ship is maintained in conformity with the present regulations. PSCO observed: uncontrolled alcohol, broken lights in stateroom, broken toilet in stateroom, broken sink in stateroom, stowage of cleaning/cooking supplies in stateroom. During this time, weekly inspections of accomodation spaces showed no issues despite being required items in the vessels SMS. An internal safety audit is required within 3 months.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 July 2023
Resolved 13 June 2023
Resolution: received satisfactory report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2023 Resolved
Means shall be provided to control the leaks of flammable liquids, PSCO observed F/O leak from #1 F/O pump in purifier space.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2023
Resolved 27 April 2023
Resolution: Recieved class report attesting that the pump's seals were replaced and no further leakage was observed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2023 Resolved
Means shall be provided to limit the accumulation of flammable vapors. PSCO observed pool of MGO/water mixture, in a steel sink, in the purifier space.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2023
Resolved 27 April 2023
Resolution: Recieved class report attesting that the oily water mixture was cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 April 2023 Resolved
Electrical insulations shall be such that: The safety of crew and ship from elecrical hazards will be ensured. PSCO observed electrical splices and exposed wires in laundry room.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 27 April 2023
Resolution: Recieved class report attesting to the repair and proper wiring of electrical wires in laundry room.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 April 2023 Resolved
PSCO observed inoperable lights, broken toilets, broken sinks in crew staterooms. Instances of storing cooking and oceanic supplies in staterooms also observed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 June 2023
Resolved 13 June 2023
Resolution: received satisfactory report
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 April 2023 Resolved
Fire-fighting systems and appliances shall be maintained and ready for use. PSCO observed the emergency fire pump needing 30 minutes to operate.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 26 April 2023
Resolution: Fire pump was able to operate.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 26 April 2023 Resolved
The ship shall comply with the requirements of the ISM Code. The company should establish procedures, plans, and instructions for key shipboard operations. PSCO observed cases of beer store unsecured, despite vessels SMS requiring alcohol consumption being "regulated and controlled by the Master."
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 8 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 26 April 2023 Resolved
General arrangement plans shall be permanently exhibited, with the particulars of the sprinler installation. PSCO observed fire control showing out of service CO2 system.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 June 2023
Resolved 27 April 2023
Resolution: Class Report attesting to defiency being corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 20 June 2022 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPTMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED THE POWER CABLE FOR THE #2 BLOWER ON MAIN ENGINE HAD BEEN DISCONNECTED AND WRAPPED WITH ELETRICAL TAPE AND TRASH BAGS. ALSO NO LOCK OUT OR TAG OUT PROCEDURES WERE USED FOR THE BREAKER. SOLAS I/11(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 August 2022
Resolution: Recieved class report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2021 Resolved
99101 - Other (Safety in general) - A ship when in port of another Contracting Government is subject to control by officers duly authorized by such Government concerning operational requirements in respect of the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. The crew was unfamiliar with how to properly install life raft float free arrangement. PSCO educated the crew on how to properly install the life raft system and how it operates. - 74 SOLAS (20) XI-1/4.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 December 2021
Resolution: PSCO educated the crew on how to properly install the life raft system and how it operates.
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 18 December 2021 Resolved
11110 - Stowage and provision of liferafts - Each life raft or group of life rafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code so that each floats free and, if inflatable, infaltes automatically when the ship sinks. PSCO discovered the 2nd life raft's float free system on the starboard side was set up incorrectly. - 74 SOLAS (20) III/13.4.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 December 2021
Resolution: Crew installed the hydrostatic release the proper way.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.