MAURY USCG vessel records Sign in
← All vessels

WAN HAI 612

WAN HAI 612 is a 2001 freight ship. The Coast Guard has recorded 33 inspections since 2002, most recently in July 2023, along with 16 deficiencies and 6 operational controls.

Records from 2002 to 2023. Most recent: operational control imposed, 15 July 2023.

Built
2001
Last inspected
15 July 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9224518 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3465
568330
Flag
SINGAPORE
—
Maury page id
psix-568330

Inspections, by type

…with no type recorded10
Years with a record 16 calendar years (2002–2023)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25395 - Convention (Subpart B), Net Ton
71395 - Dead Weight, Metric Ton
95895 - Displacement, Metric Ton
68687 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

15 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742982
13 June 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7713788
29 April 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7676597
26 April 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7674657
20 June 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7471651
7 March 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7407482
14 February 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7396188
18 December 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7370044
8 December 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364995
9 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812292
22 December 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5785893
21 October 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5004323
29 July 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4097696
28 December 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3917057
11 March 2009 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3431661
14 February 2009 Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3416835
16 August 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3293298
20 June 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2968339
20 June 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2968373
25 May 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2939737
3 July 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2699769
11 March 2005 Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2308060
3 March 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2303117
16 September 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2197573
28 July 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2148085
19 June 2004 MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2103624
29 March 2004 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2033214
29 March 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2034043
21 July 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1853019
2 February 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1738529
2 February 2003 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1738691
26 May 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1620902
26 May 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1702885

Deficiency record · 16

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 26 April 2023 Resolved
The ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that the ship is maintained in conformity with the present regulations. PSCO observed: uncontrolled alcohol, broken lights in stateroom, broken toilet in stateroom, broken sink in stateroom, stowage of cleaning/cooking supplies in stateroom. During this time, weekly inspections of accomodation spaces showed no issues despite being required items in the vessels SMS. An internal safety audit is required within 3 months.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 July 2023
Resolved 13 June 2023
Resolution: received satisfactory report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2023 Resolved
Means shall be provided to control the leaks of flammable liquids, PSCO observed F/O leak from #1 F/O pump in purifier space.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2023
Resolved 27 April 2023
Resolution: Recieved class report attesting that the pump's seals were replaced and no further leakage was observed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2023 Resolved
Means shall be provided to limit the accumulation of flammable vapors. PSCO observed pool of MGO/water mixture, in a steel sink, in the purifier space.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2023
Resolved 27 April 2023
Resolution: Recieved class report attesting that the oily water mixture was cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 April 2023 Resolved
Electrical insulations shall be such that: The safety of crew and ship from elecrical hazards will be ensured. PSCO observed electrical splices and exposed wires in laundry room.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 27 April 2023
Resolution: Recieved class report attesting to the repair and proper wiring of electrical wires in laundry room.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 April 2023 Resolved
PSCO observed inoperable lights, broken toilets, broken sinks in crew staterooms. Instances of storing cooking and oceanic supplies in staterooms also observed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 June 2023
Resolved 13 June 2023
Resolution: received satisfactory report
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 April 2023 Resolved
Fire-fighting systems and appliances shall be maintained and ready for use. PSCO observed the emergency fire pump needing 30 minutes to operate.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 26 April 2023
Resolution: Fire pump was able to operate.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 26 April 2023 Resolved
The ship shall comply with the requirements of the ISM Code. The company should establish procedures, plans, and instructions for key shipboard operations. PSCO observed cases of beer store unsecured, despite vessels SMS requiring alcohol consumption being "regulated and controlled by the Master."
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 8 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 26 April 2023 Resolved
General arrangement plans shall be permanently exhibited, with the particulars of the sprinler installation. PSCO observed fire control showing out of service CO2 system.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 June 2023
Resolved 27 April 2023
Resolution: Class Report attesting to defiency being corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 20 June 2022 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPTMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED THE POWER CABLE FOR THE #2 BLOWER ON MAIN ENGINE HAD BEEN DISCONNECTED AND WRAPPED WITH ELETRICAL TAPE AND TRASH BAGS. ALSO NO LOCK OUT OR TAG OUT PROCEDURES WERE USED FOR THE BREAKER. SOLAS I/11(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 August 2022
Resolution: Recieved class report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2021 Resolved
99101 - Other (Safety in general) - A ship when in port of another Contracting Government is subject to control by officers duly authorized by such Government concerning operational requirements in respect of the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. The crew was unfamiliar with how to properly install life raft float free arrangement. PSCO educated the crew on how to properly install the life raft system and how it operates. - 74 SOLAS (20) XI-1/4.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 December 2021
Resolution: PSCO educated the crew on how to properly install the life raft system and how it operates.
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 18 December 2021 Resolved
11110 - Stowage and provision of liferafts - Each life raft or group of life rafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code so that each floats free and, if inflatable, infaltes automatically when the ship sinks. PSCO discovered the 2nd life raft's float free system on the starboard side was set up incorrectly. - 74 SOLAS (20) III/13.4.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 December 2021
Resolution: Crew installed the hydrostatic release the proper way.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 22 December 2015 Resolved
The forward most door in the Purifying Room has a damaged frame located on the bottom of the frame, which can allow smoke to pass through the "A" class Fire Door Boundary. 74 SOLAS(01 Cons.), II-2/47.1 (40 a.c.)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 December 2015
Resolved 24 January 2016
Resolution: Received DNV-GL report of corrected status. See Attachement in Documents
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 22 December 2015 Resolved
IAW Vessel Fire Control Plan, Fire Doors leading in and out of Galley must be self-closing. Self-closing mechanisms were not properly mounted, doors would not close themselves. 74 SOLAS (01 cons.) II-2/20.1 (10 c.)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 22 December 2015
Resolution: Vessel corrected improper installation of closing device.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2009 Resolved
Dent and buckling of frame at frames 4 and 5 on port side aft in area of steering flat. Damage is above the water line.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 March 2009
Resolved 11 March 2009
Resolution: Received class report stating, "To be repaired permanently by next dry dock but not later than 24Sep2011."
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 20 June 2007 Resolved
23 May 2007: Vessel entered Port of Long Beach without a valid COFR. Issued NOV, and required company to resolve issue with COFR Desk prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2007
Resolved 20 June 2007
Resolution: Recv''''d notification from NPFC that COFR has been re-instated.
Electrical › Electric Generation Source (emergency)
Issued 28 March 2004 Resolved
Emergency generator would not start automatically. SOLAS CH.2 REG 43-44 LEGACY COMPONENT DESC: Generator
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2004
Resolved 29 March 2004
Resolution: Generator repaired to the satisfatcion of attending USCG inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.