SEAFARI is a passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in July 2025, along with 20 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 31 July 2025.

Built
Not recorded
Last inspected
31 July 2025
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

KCF2709H
570063
Flag
UNITED STATES
Maury page id
psix-570063

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)33.7 ft × 9.7 ft × 3.4 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNot recorded
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARINA DEL REY, CA
Trade endorsementsRecreational
DocumentationExpired · issued 3 October 2017
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 22

31 July 2025 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8197747
29 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7956152
29 August 2024 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016127
7 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7700936
26 July 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7700897
16 June 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466192
13 July 2021 Annual Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7254676
1 July 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7241961
18 November 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7097388
20 October 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7081295
12 August 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6727398
24 June 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706017
13 August 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6488603
19 June 2017 Administrative Inspection · In-Service Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6167816
6 June 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6163920
8 May 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129095
15 December 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6054065
15 December 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6302573
22 November 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6041475
30 October 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6087851
26 February 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5821277
29 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5803229

Deficiency record · 20

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two lifejackets removed from service & four life jackets need retroreflective tape. Passenger count reduced to 12 passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2024
Resolution: Two lifejackets replaced. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 August 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (3) The pump is permanently mounted. Bilge pump in the forward compartment is not permanently mounted.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 August 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 August 2024 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first ait kit missing a tourniquet and ammonia inhalants.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2024
Resolution: Vessel replaced first aid kit w/ brand new tourniquet. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 July 2023 Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to at least 6 inches about the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Through hull valve (Ball valve) does not close fully, valve is for raw water cooling for main engine. Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 July 2023
Resolution: New ball valve installed and verified proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2021 Resolved
THE OWNER OR MANAGING OPERATOR SHALL MAKE A VESSEL AVAILABLE FOR DRYDOCKN EXAMINATIONS AT LEAST ONCE EVERY TWO YEARS. THE VESSEL HAS NOT COMPLETED A SATISFACTORY DRYDOCK EXAMINATION. VESSEL CANNOT CARRY PASSENGERS UNTIL SATISFACTORY EXAMINATION IS COMPLETED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2021
Resolved 13 July 2021
Resolution: MI Conducted satisfactory Annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2020 Resolved
Exhaust gas must not leak from the piping or any connections. MI discovered exhaust leak at top of manifold/exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 3 December 2020
Resolution: Top of exhaust pipe was replaced with new and satisfactorily tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2020 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2020
Resolved 18 November 2020
Resolution: Completed Annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Discovered two lifejackets with holes, 14 lifejackets remain serviceable. Replace 1 lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 3 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019 Resolved
The identification of items stowed inside must be marked on each container for lifejackets. Two lifejacket containers were not labeled. Label lifejacket containers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 3 September 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 August 2018 Resolved
Provide fire-servicing certificate/report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 12 August 2019
Resolution: Deficiency superseded by 2019 annual inspeciton where it was verified servicing was completed satisfactorily in July 2019 by Breakwater International, Inc.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2018 Resolved
Provide retroreflective tape on life ring.
Action required: 10 - Deficiency Rectified
Resolved 13 August 2018
Resolution: Provided retro reflective tape on life ring to the satisfaction of the MI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 May 2017 Resolved
Provide a visual indicator at the operating station for the fwd automatic bilge pump. 46CFR182.530(c)
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner installed visual indicator at operating station for fwd automatic bilge pump.
Communications › Alarms/Indicators › High Water Alarm
Issued 8 May 2017 Resolved
Provide a visual and audible alarm at the operating station for the bilge high level alarm at the fwd compartment. 46CFR182.530(a)
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner installed a visual and audible alarm at the operating station for the bilge high level alarm.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 May 2017 Resolved
Properly label identified life jacket storage. 46CFR185.604(f)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner correctly labeled identified life jacket storage with correct size and number of life jackets.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 8 May 2017 Resolved
Relabel vessel registration numbers on port bow so it is clearly visible. 46CFR67.123(a)
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner relabeled registration numbers on port bow.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 November 2016 Resolved
INSTALL VISUAL AND AUDIBLE ALARMS AT THE OPERATING STATION FOR BILGE SPACES AS INDICATED. TO BE COMPLETED TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2016
Resolution: See narrative.
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 November 2016 Resolved
REPAIR AFT BENCH TO PREVENT DAMAGE TO BATTERIES. OLD-T 183.01-15
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 15 December 2016
Resolution: Aft bench supports repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 November 2016 Resolved
SECURE NAVIGATION LIGHT WIRING TO OVERHEAD. OLD-T 183.05-50
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 25 November 2016
Resolution: See Narrative.
Engineering › Fuel Oil Service System › Hose
Issued 22 November 2016 Resolved
PROVIDE MEANS TO PROTECT FUEL INLET HOSE FROM UNECESSARY CHAFING. OLD-T 182.20-40
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 25 November 2016
Resolution: See Narrative.
Documentation › Logs/Records › Logbook (official)
Issued 29 January 2016 Resolved
Vessel does not have an official log book, provide an official log book on board.
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 29 January 2016
Resolution: Vessel owner purchased and provided a new official log book on board, fixed on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.