MAURY USCG vessel records Sign in
← All vessels

SEAFARI

SEAFARI is a passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 2002, most recently in July 2025, along with 80 deficiencies and 8 operational controls.

Records from 2002 to 2025. Most recent: inspection, 31 July 2025.

Built
Not recorded
Last inspected
31 July 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

KCF2709H
570063
Flag
UNITED STATES
—
Maury page id
psix-570063

Inspections, by type

…with no type recorded1
Years with a record 22 calendar years (2002–2025)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)33.7 ft × 9.7 ft × 3.4 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNot recorded
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARINA DEL REY, CA
Trade endorsementsRecreational
DocumentationExpired · issued 3 October 2017
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

31 July 2025 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8197747
29 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7956152
29 August 2024 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016127
7 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7700936
26 July 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7700897
16 June 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466192
13 July 2021 Annual Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7254676
1 July 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7241961
18 November 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7097388
20 October 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7081295
12 August 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6727398
24 June 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706017
13 August 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6488603
19 June 2017 Administrative Inspection · In-Service Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6167816
6 June 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6163920
8 May 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129095
15 December 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6054065
15 December 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6302573
22 November 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6041475
30 October 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6087851
26 February 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5821277
29 January 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5803229
22 October 2015 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5739753
30 October 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5008975
28 October 2014 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5013861
24 July 2012 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4375979
10 January 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4008569
9 December 2010 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3907833
8 November 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3883933
2 December 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3643476
7 October 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3326280
26 November 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3104043
25 July 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3000731
17 July 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2999516
22 August 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2739040
13 October 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509965
6 October 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509471
13 September 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2491653
13 June 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2385314
26 August 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2156892
4 September 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1890022
20 August 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1875024
7 June 2002 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1623483

Deficiency record · 80

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two lifejackets removed from service & four life jackets need retroreflective tape. Passenger count reduced to 12 passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2024
Resolution: Two lifejackets replaced. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 August 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (3) The pump is permanently mounted. Bilge pump in the forward compartment is not permanently mounted.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 August 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 August 2024 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first ait kit missing a tourniquet and ammonia inhalants.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2024
Resolution: Vessel replaced first aid kit w/ brand new tourniquet. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 July 2023 Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to at least 6 inches about the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Through hull valve (Ball valve) does not close fully, valve is for raw water cooling for main engine. Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 July 2023
Resolution: New ball valve installed and verified proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2021 Resolved
THE OWNER OR MANAGING OPERATOR SHALL MAKE A VESSEL AVAILABLE FOR DRYDOCKN EXAMINATIONS AT LEAST ONCE EVERY TWO YEARS. THE VESSEL HAS NOT COMPLETED A SATISFACTORY DRYDOCK EXAMINATION. VESSEL CANNOT CARRY PASSENGERS UNTIL SATISFACTORY EXAMINATION IS COMPLETED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2021
Resolved 13 July 2021
Resolution: MI Conducted satisfactory Annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2020 Resolved
Exhaust gas must not leak from the piping or any connections. MI discovered exhaust leak at top of manifold/exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 3 December 2020
Resolution: Top of exhaust pipe was replaced with new and satisfactorily tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2020 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2020
Resolved 18 November 2020
Resolution: Completed Annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Discovered two lifejackets with holes, 14 lifejackets remain serviceable. Replace 1 lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 3 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019 Resolved
The identification of items stowed inside must be marked on each container for lifejackets. Two lifejacket containers were not labeled. Label lifejacket containers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 3 September 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 August 2018 Resolved
Provide fire-servicing certificate/report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 12 August 2019
Resolution: Deficiency superseded by 2019 annual inspeciton where it was verified servicing was completed satisfactorily in July 2019 by Breakwater International, Inc.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2018 Resolved
Provide retroreflective tape on life ring.
Action required: 10 - Deficiency Rectified
Resolved 13 August 2018
Resolution: Provided retro reflective tape on life ring to the satisfaction of the MI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 May 2017 Resolved
Provide a visual indicator at the operating station for the fwd automatic bilge pump. 46CFR182.530(c)
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner installed visual indicator at operating station for fwd automatic bilge pump.
Communications › Alarms/Indicators › High Water Alarm
Issued 8 May 2017 Resolved
Provide a visual and audible alarm at the operating station for the bilge high level alarm at the fwd compartment. 46CFR182.530(a)
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner installed a visual and audible alarm at the operating station for the bilge high level alarm.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 May 2017 Resolved
Properly label identified life jacket storage. 46CFR185.604(f)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner correctly labeled identified life jacket storage with correct size and number of life jackets.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 8 May 2017 Resolved
Relabel vessel registration numbers on port bow so it is clearly visible. 46CFR67.123(a)
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Owner relabeled registration numbers on port bow.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 November 2016 Resolved
INSTALL VISUAL AND AUDIBLE ALARMS AT THE OPERATING STATION FOR BILGE SPACES AS INDICATED. TO BE COMPLETED TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2016
Resolution: See narrative.
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 November 2016 Resolved
REPAIR AFT BENCH TO PREVENT DAMAGE TO BATTERIES. OLD-T 183.01-15
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 15 December 2016
Resolution: Aft bench supports repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 November 2016 Resolved
SECURE NAVIGATION LIGHT WIRING TO OVERHEAD. OLD-T 183.05-50
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 25 November 2016
Resolution: See Narrative.
Engineering › Fuel Oil Service System › Hose
Issued 22 November 2016 Resolved
PROVIDE MEANS TO PROTECT FUEL INLET HOSE FROM UNECESSARY CHAFING. OLD-T 182.20-40
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 25 November 2016
Resolution: See Narrative.
Documentation › Logs/Records › Logbook (official)
Issued 29 January 2016 Resolved
Vessel does not have an official log book, provide an official log book on board.
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 29 January 2016
Resolution: Vessel owner purchased and provided a new official log book on board, fixed on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 November 2015 Resolved
Life jacket storage was not properly labeled with number of adult life jackets. Mark life jacket stowage with correct number.
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 26 February 2016
Resolution: Properly labeled storage with correct number of lifejackets.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 October 2015 Resolved
Vessel master was unable to present valid master credentials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2015
Resolution: Master presented his valid credentials
Fire Fighting › Fire Bucket › Quantity
Issued 22 October 2015 Resolved
Vessel had two fire buckets that were not properly labeled. Vessel is required to have (3) fire buckets labeled "FIRE BUCKETS"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2015
Resolution: Vessel provided 3 2.5 gallon fire buckets
Engineering › Bilge Water Management System › Pump
Issued 22 October 2015 Resolved
Vessels bilge pump was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2015
Resolution: Forward bilge pump was replaced and tested
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 October 2015 Resolved
Water cooling hose was not double clamped and was not made of braided or non collapsible material.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Jacket water hose replaced and double clamps placed throughout the water system
Navigation › Piloting/Steering › Marine Charts
Issued 22 October 2015 Resolved
Vessel did not have updated charts onboard.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 26 February 2016
Resolution: Provided updated charts
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Seal
Issued 22 October 2015 Resolved
Exessive fuel leak on main engine and RAYCOR fule filter. Must be installed an maintained to afford protection from fire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2015
Resolution: RACOR and fuel supply/return lines replaced no fuel leaks evident during engine test
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 October 2015 Resolved
Life jacket donning placard was not mounted
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Life jacket donning placard was permanently placed on the vessel easily viewable by the passengers
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 22 October 2015 Resolved
Retro-reflective tape must be renewed/replaced on 11 adult life jackets and 2 child life jackets.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: New retro reflective tape was placed on all life jackets aboard.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 October 2015 Resolved
Stern navigation light was inoperable and not of approved UL type.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Vessel installed new UL approved stern light
Fire Fighting › Fire Bucket › Quantity
Issued 22 October 2015 Resolved
Vessel had one fire bucket onboard and not the required 3- 2.5 gallon bucket properly labeled "FIRE BUCKET"
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Vessel provided 3 2.5 gallon fire buckets
Fire Fighting › Combustible Materials › Insulation
Issued 22 October 2015 Resolved
Fire insulation/protective covering in center consol was ripped and missing in most areas. Vessel must replace or repair insulation.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Fire insulation was replaced within the engine compartment
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 October 2015 Resolved
Emergency shut off valve was not properly labeled.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Vessel properly labeled emergency fuel shut off valve
Electrical › Electric Supply System (service) › Cable
Issued 22 October 2015 Resolved
Vessel must remove all dead end wires and run electrical wiring as far above the bilge as practical.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Dead end wires removed throughout the vessel
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 October 2015 Resolved
Vessel must have battery operated lantern at operating station.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Vessel provided battery operated lantern for the operating station
Engineering › Lubricating Oil Service System › Cooler
Issued 22 October 2015 Resolved
Replace missing cap on coolant container.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: New cap provided for the water coolant container
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 October 2015 Resolved
Life line on ring buoy was not of the float type and resistant to ultraviolet light.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Life ring buoy line was replaced with uv resistant and buoyant line as required
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 October 2015 Resolved
vessel was not equipped with CG approved first aid kit.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Vessel provided new first aid kit
Engineering › Fuel Oil Service System › Hose
Issued 22 October 2015 Resolved
Replace broken hose clamps on fuel lines on diesel engine.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: RACOR and fuel supply/return lines replaced no fuel leaks evident during engine test
Construction/Loadline › Structures › Superstructure
Issued 22 October 2015 Resolved
Vessel must remove canopy sunshade rigged with rope. It must be able to withstand max wave and wind conditions.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 16 November 2015
Resolution: Canopy sunshade was removed from the vessel
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 30 October 2014 Resolved
Provide 2013 Management Information System (MIS) Documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 30 October 2014
Resolution: MIS report was available for inspection
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 October 2014 Resolved
Renew annual inspection to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 30 October 2014
Resolution: Completed annual inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 28 October 2014 Resolved
Provide proof of annual fire extinguisher servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2014
Resolved 31 October 2014
Resolution: Provided proof of fire extinguisher servicing on 31OCT14 by Professional Fire Protection Company, Inc.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 October 2014 Resolved
Permenantly mount steering consol.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: Console mounted properly
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 October 2014 Resolved
Replace indicated plywood floor board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: Plywood replaced
Engineering › Steering Gear System › Cable
Issued 28 October 2014 Resolved
Provide permenant clamp for steering cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: A metal hose clamp was installed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 October 2014 Resolved
Mark ring buoy with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: Name of vessel permanently marked
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 October 2014 Resolved
Post drug information hotline number.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: Hotline number was already in the DAPI program manual
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 October 2014 Resolved
Provide cover for engine room vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: Engine room vent cover was installed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 October 2014 Resolved
Secure 04 canopy supports to canopy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 28 October 2014
Resolution: New bolts were installed in canopy supports.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 July 2012 Resolved
Provide proper fuel tank remote shut-off valve IAW 46 CFR 182.455
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 23 August 2012
Resolution: Installed an access plate to the valve reducing the distance to 10".
Fire Fighting › Fire Bucket › Quantity
Issued 24 July 2012 Resolved
Provide additional fie buckets IAW 46 CFR 181.610
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 23 August 2012
Resolution: Provided proper amount of fire buckets.
Lifesaving › Hand Flares › Not on Board
Issued 24 July 2012 Resolved
Provide three orange smoke distress signals IAW 46 CFR 180.68
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 23 August 2012
Resolution: Provided proper amount of flares.
Lifesaving › Lifebuoys › Size
Issued 24 July 2012 Resolved
Provide ring life buoy of proper size IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 23 August 2012
Resolution: Provided proper size life ring buoy.
Navigation › Piloting/Steering › Marine Charts
Issued 8 November 2010 Resolved
Provide an up-to-date nautical chart for Newport Bay I.A.W. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 9 December 2010
Resolution: Owner/operator provided a new print-on-demand chart.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 November 2010 Resolved
Provide an Emergency Broadcast Placard as required by 46 CFR 184.506 at the operating station.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 9 December 2010
Resolution: Owner-operator posted a satisfactory placard.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 November 2010 Resolved
Post Emergency Instructions as required by 46 CFR 185.510 where visible to crew and passengers.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 9 December 2010
Resolution: Owner-operator posted satisfactory instructions.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 December 2009 Resolved
Provide proof of servicing of all portable fire extinguishers onboard vessel IAW 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2010
Resolved 4 December 2009
Resolution: Owner purchased a new B- I portable fire extinguisher.
Lifesaving › Hand Flares › Quantity
Issued 2 December 2009 Resolved
Provide required amount of distress flares IAW 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2010
Resolved 4 December 2009
Resolution: Owner purchased new distress flares.
Engineering › Fuel Oil Service System › Hose
Issued 2 December 2009 Resolved
Repair fuel leak on main diesel engine and provide clamps on all fuel lines IAW 46 CFR 182.720.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2010
Resolved 4 December 2009
Resolution: Fuel leak repaired and clamps were installed on all fuel lines.
Documentation › Logs/Records › Drug Test Records
Issued 2 December 2009 Resolved
Provide remaining documents for drug & alcohol program IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 1 February 2010
Resolution: Remaining documents reviewed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 October 2008 Resolved
Provide evidence of current compliance with Drug and Alcohol Testing Program IAW 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2008
Resolution: Consortium provided evidence of operator''s enrollment in DAPI program.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 October 2008 Resolved
Provide proof of annual testing for portable fire extinguishers IAW 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2008
Resolution: Replaced expired fire extinguishers.
Lifesaving › Hand Flares › Quantity
Issued 7 October 2008 Resolved
Obtain 3 additional flares for vessel IAW 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2008
Resolved 5 November 2008
Resolution: Vessel now carries the required type and number of flares.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 October 2008 Resolved
Label all lifejacket stowage spaces and ensure that no sharp objects can tear/puncture pfd's IAW 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 6 November 2008
Resolved 5 November 2008
Resolution: Lifejacket stowage spaces properly labeled. Nail ends were cut off to prevent pfd punctures.
Documentation › Certificates/Documents › FCC SSL
Issued 7 October 2008 Resolved
Provide evidence of FCC compliance to include: Safety certificate and station license IAW 46 CFR 184.502. Vessel operation restricted to no more than 1,000 feet from shore until requirement is met.
Action required: 705 - Other - as specified
Due 6 November 2008
Resolved 5 November 2008
Resolution: Provided proof of current FCC compliance.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 October 2008 Resolved
Properly label first aid kit and replace expired items IAW 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 6 November 2008
Resolved 5 November 2008
Resolution: First aid kit was properly labeled and stocked.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 7 October 2008 Resolved
Re-attach ground for cathodic protection located in steering box IAW 46 CFR 183.370.
Action required: 705 - Other - as specified
Due 6 November 2008
Resolved 5 November 2008
Resolution: Affectively re-attached ground.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 25 July 2007 Resolved
Provide proof of EAP training.
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 8 August 2007
Resolution: Inspector confirmed that the EAP DVD was ordered through The Maritime Consortium, INC on 8/8/07
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 July 2007 Resolved
Provide proof that all employees are enrolled in the random testing program through the consortium.
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 31 July 2007
Resolution: Owner faxed over a copy of the Confirmation of enrollment for random drug testing for all employees.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 July 2007 Resolved
Vessel's COI expired on 07JUN2007. Submit application for renewal of Certificate of Inspection I.A.W. 46 CFR 176.100 and 176.105.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2007
Resolved 25 July 2007
Resolution: Satisfactory COI exam performed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 October 2005 Resolved
Complete successful hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2005
Resolved 13 October 2005
Resolution: Hull exam successfully completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 13 June 2005 Resolved
Provided current Fire Fighting servicing report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2005
Resolved 22 June 2005
Resolution: Provided current Fire Fighting servicing report.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 June 2005 Resolved
Prove current Drug Testing program IAW 46CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2005
Resolved 21 June 2005
Resolution: Provided current enrollment with drug testing consortium.
Deck/Cargo › Holds/Tanks
Issued 4 September 2003 Resolved
Attach weathertight hatch on lazarette by hinge or captive chain in accordance with 46 CFR 171.124(a)(3) and 171.124(b)(2). LEGACY COMPONENT DESC: Hatch
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 September 2003
Resolved 18 September 2003
Resolution: Attached weathertight hatch on lazarette by hinge or captive chain.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 August 2003 Resolved
Service fixed fire fighting system and attain servicing report from an approved servicing facility.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2003
Resolution: Serviced fixed fire fighting system.
Lifesaving › Lifebuoys
Issued 20 August 2003 Resolved
Repair/replace waterlight for ring life buoy LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 4 September 2003
Resolution: Replaced waterlight for ring life buoy.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 20 August 2003 Resolved
Properly mount forward fire extinguisher. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 4 September 2003
Resolution: Properly mounted forward fire extinguisher.
Navigation › Collision/Grounding Avoidance
Issued 20 August 2003 Resolved
Repair/replace masthead light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2003
Resolved 4 September 2003
Resolution: Replaced masthead light.
Construction/Loadline › Hull
Issued 20 August 2003 Resolved
Complete satisfactory hull examination.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2003
Resolution: Completed satisfactory hull examination.

Ownership record