MAURY USCG vessel records Sign in
← All vessels

ZODIAC

ZODIAC is a 1924 passenger vessel (inspected). The Coast Guard has recorded 109 inspections since 1988, most recently in June 2026, along with 60 deficiencies and 3 casualty investigations between 2010 and 2019.

Records from 1988 to 2026. Most recent: inspection, 3 June 2026.

Built
1924
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7937587 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WTH5653
Flag
UNITED STATES
366968070
Maury page id
psix-57090

Inspections, by type

…with no type recorded17
Years with a record 36 calendar years (1988–2026)
The 109 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)110.0 ft × 24.6 ft × 18.5 ft
Registered tonnagegross 147 / net 44
ITC dimensions (L × B × D)110.0 ft × 24.6 ft × 18.5 ft
ITC tonnagegross 147 / net 44
Builderbuilder not recorded · EAST BOOTHBAY, MA, UNITED STATES · built 1924
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLINGHAM, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 15 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it147 - Convention (Subpart B), Gross Ton
44 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

EX360MMSI 366968070 · active · exemption · granted 21 May 2026, expires 21 May 2030
WTH5653MMSI 366968070 · active · compulsorily equipped · granted 28 June 2024, expires 27 May 2034
EX143MMSI 366968070 · expired · exemption · granted 28 June 2022, cancelled 4 July 2026
EX96MMSI 366968070 · expired · exemption · granted 12 April 2007, cancelled 30 April 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 109

3 June 2026 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8344362
2 December 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8276591
4 June 2025 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8152330
11 December 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8046347
26 June 2024 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7941667
13 May 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7911719
21 February 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868515
6 February 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7861813
27 June 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7721226
13 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7649144
1 July 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7496900
17 March 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412229
24 June 2021 Exemption
Administrative · USCG Northwest District (dp) · USCG Northwest District (CGD-NW) · Activity 7235279
1 June 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7206702
19 May 2021 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7176886
8 December 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7108730
25 June 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6990821
13 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926305
28 February 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6917833
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809217
21 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6798084
9 April 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6658586
8 April 2019 MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655327
18 March 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6639302
30 March 2018 Internal Structural Exam · COI Inspection · MTSA Verification · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6378693
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360560
6 September 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6265428
31 August 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6256544
13 April 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6124085
6 April 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117191
21 February 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6118653
25 March 2016 Drydock Exam · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840719
22 September 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5752754
18 August 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5220312
17 July 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5191510
7 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203674
25 September 2010 Type not recorded
No type recorded · Station Bellingham · USCG Northwest District (CGD-NW) · Activity 3857551
25 September 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3858268
25 September 2010 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3859166
23 March 2010 MTSA/ISPS Verification · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3701593
24 March 2009 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3437385
13 January 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3393204
4 April 2008 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3176767
30 January 2008 Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3153829
29 January 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3138567
18 October 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3082306
20 September 2007 MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3062455
11 April 2007 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2905849
5 February 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2867500
22 January 2007 Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2867442
7 August 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2739006
2 June 2006 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2668448
11 April 2006 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2622461
29 March 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2616846
13 October 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2513977
6 June 2005 MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2381422
14 April 2005 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2333709
31 January 2005 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2282361
28 July 2004 MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2148463
30 June 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2116828
16 April 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2042350
16 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2025738
26 February 2004 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2013549
16 April 2003 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1774216
4 March 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1752424
27 August 2002 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1667369
9 April 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1599218
19 February 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1487396
2 April 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1437877
12 February 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1059520
31 March 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1457769
22 February 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 815879
14 February 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 152467
8 April 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404730
8 March 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 806369
19 August 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1456624
29 June 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1130236
22 May 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396933
3 April 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390752
31 March 1998 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381180
30 January 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388456
19 December 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1368513
31 March 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385951
31 January 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435861
8 April 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1433031
26 February 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425655
31 July 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1405771
5 April 1995 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394311
2 March 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353706
17 February 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 850747
20 April 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429876
23 February 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373995
30 April 1993 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 839984
12 February 1993 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469751
11 May 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1270200
9 March 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1321086
5 December 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943141
9 August 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1243740
24 May 1991 Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229213
12 April 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1228648
27 March 1991 Deadweight Survey · Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1228235
9 August 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1236032
23 July 1990 Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 919756
21 May 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907770
9 January 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1215258
6 September 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 886533
15 June 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1036415
19 April 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1035504
31 October 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 891337

Deficiency record · 60

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION THE MARINE INSPECTOR SHALL EXAMINE AND TEST THE FOLLOWING ITEMS TO THE EXTENCT NECESSARY TO DETERMINE THAT THEY ARE IN PROPER OPERATING CONDITION, SAFE ELECTRICAL CONDITION, SAFE ELECTRICAL CONDITION AND FIT FOR THE SERVICE FOR WHICH THEY ARE INTENDED: OVERLOAD OR CIRCUIT PROTECTION DEVICES. CIRCUIT BREAKERS SHALL BE TESTED BY MANUAL OPERATION AND FUSES SHALL BE EXAMINED VISUALLY. THE RATINGS OF FUSES SHALL BE CHECKED TO DETERMINE SUITABILITY OF THE INTENDED SERVICE. BREAKER BOX 'A', CIRCUIT #22/#24 HAD 45 AMP BREAKER WITH 12 AWG CABLE GOING TO AN ELECTRIC MOTOR/PUMP. INSTALL 20 AMP BREAKER AS APPROPRIATE FOR OVERCURRENT PROTECTION. 46 CFR 176.25-15(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 9 June 2026
Resolution: Recieved photo of newly installed breakers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION THE MARINE INSPECTOR SHALL EXAMINE AND TEST THE FOLLOWING ITEMS TO THE EXTENCT NECESSARY TO DETERMINE THAT THEY ARE IN PROPER OPERATING CONDITION, SAFE ELECTRICAL CONDITION, SAFE ELECTRICAL CONDITION AND FIT FOR THE SERVICE FOR WHICH THEY ARE INTENDED: OVERLOAD OR CIRCUIT PROTECTION DEVICES. ELECTRICAL CABLE. THE CABLE SHALL BE EXAMINED AS FAR AS PRACTICABLE WITHOUT UNDUE DISTURBANCE OF THE CABLE OR ELECTRICAL APPARATUS. BREAKER BOX 'B', CIRCUIT #20. THE CABLE LEAVING THE BREAKER BOX HAS BEEN STRETCHED TO THE POINT OF WITHDRAWING THE INSULATION FROM THE CABLE AND EXPOSING THE THREE STRAND CONDUCTORS INSIDE. INSTALL A PROPERLY SIZED CABLE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 176.25-15(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 9 June 2026
Resolution: Recieved photo of newly installed cable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2026 Resolved
THE NUMBER AND IDENTIFICATION OF THE ITEMS STOWED INSIDE, AND THEIR SIZES, MUST BE MARKED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH CONTAINER FOR LIFE JACKETS...IDENTIFICATION OF THE ITEMS MAY BE WORDS OR THE APPROPRIATE SYMBOLS IN IMO RES A.760(18). LETTERS AND NUMBERS MUST BE AT LEAST 2 INCHES HIGH. STORAGE BIN ON DECK FOR CHILD SIZE LIFE JACKETS WERE FOUND WITH OUT THE QUANTITY LISTED AND THE LIFEJACKETS STORED IN THE SALOON WERE NOT PROPERLY LABELED TO EASILY IDENTIFY THEIR LOCATIONS. INSTALL PROPER MARKINGS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 19 June 2026
Resolution: Recieved photos on newly installed labeling.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 June 2026 Resolved
THESE REGULATIONS PRESCRIBE THE MINIMUM STANDARDS, PROCEDURES, AND MEANS TO BE USED TO TEST FOR THE USE OF DANGEROUS DRUGS. PROVIDE EVIDENCE OF ENROLLEMENT IN A CONSORTIUM OR THE MANAGEMENT INFORMATION SYSTEM REPORT. 46 CFR 16.101(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 9 June 2026
Resolution: Recieved documentation of DAPI program.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 June 2025 Resolved
At each inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including...operation of the fire main system and checking of the pressure at the most remote and highest outlets. Fire pump observed leaking and packing overheating during operational test. 46 CFR 176.810(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 24 June 2025
Resolution: Owner provided video of satisfactory operation of the fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 June 2025 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. The current random drug testing program includes six crewmembers. Minimum safe manning for 24-hour operations necessitates eight crewmembers, the program must be revised to ensure all personnel filling these positions are subject to random testing.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 11 July 2025
Resolution: Provided documentation for random drug testing program including eight crewmembers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 2 July 2024
Resolution: O/O provided new radio station license
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2019 Resolved
11118/46CFR180.71/10c - ADULT LIFEJACKETS MUST BE PROVIDED FOR EACH PERSON ONBOARD. VESSEL MAINTAINED 55 SUITABLE ADULT SIZED LIFEJACKETS. PERSONS ONBOARD LIMITED TO 55 UNTIL 4 ADDITIONAL LIFEJACKETS ARE PROVIDED IN ACCORDANCE WITH COI.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: OPERATOR PROVIDED NEW LIFEJACKETS FROM OFFSITE LOCATION PRIOR TO END OF INSPECTION.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2019 Resolved
11118/46CFR155.604(h)/10c - LIFEJACKETS MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL IN ACCORDANCE WITH IMO RES. A.658. ATTACH NEW RETROREFLECTIVE MATERIAL TO 3 ADULT SIZED LIFEJACKETS AND 1 CHILD SIZED LIFEJACKET.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: OPERATOR ATTACHED NEW RETROREFLECTIVE TAPE TO ALL LIFEJACKETS REQUIRING NEW RETRO PRIOR TO THE END OF INSPECTION.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 April 2018 Resolved
Repair gaskets on 03 watertight doors to make water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2018
Resolution: Received pictures illustrating chalk test.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 April 2018 Resolved
Provide updated charts with corrections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2018
Resolution: Rcvd picture of corrected chart.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 April 2018 Resolved
Repair watertight bulkhead penetration in aft bulkhead in space below galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 12 April 2018
Resolution: Rcvd picture of sealed bulkhead penetrations.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 April 2018 Resolved
Conduct monthly tests of rescue boat and EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 23 April 2018
Resolution: Rcvd picture of logs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2018 Resolved
Provide documentation to complete DAPI Program include alcohol test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 26 April 2018
Resolution: DAPI documentation was provided via email.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 September 2010 Resolved
Survey and repair broken mast and rigging prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2011
Resolved 15 April 2011
Resolution: Rigging was surveyed, mast was replaced, extensive work was completed, various inspections have been done, and underway test was completed. All satisfactory.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 24 March 2009 Resolved
Install upon return from servicing. Prove proper installation and provide proof of service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: Witnessed installation and rcvd servicing certificate.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 March 2009 Resolved
Label child size PFD stowage.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Stowage properly labeled.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 March 2009 Resolved
Procure, label, and stow 7 adult PFDs in place of PFDs condemned due to seams and/or leaking kapok.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: Provided proper number of PFDs for full capacity per COI.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 March 2009 Resolved
Provide proof of enrollment in program.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Provided proof of enrollment from facility.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2009 Resolved
Must conduct U/W check ride, after completion of DDX.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2009
Resolution: U/W check ride completed during COI exam.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 April 2007 Resolved
Replace 14 defective lifejackets
Due 12 May 2007
Resolved 27 April 2007
Resolution: Replaced 14 lifejackets
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 April 2007 Resolved
Stencil life jacket location on deck.
Due 12 May 2007
Resolved 17 May 2007
Resolution: Stenciled life jacket location
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 April 2007 Resolved
Install a visual alarm in addition to the audible alarm for each sub division aft of the collision bulkhead at the operation station for the bilge alarms.
Due 12 May 2007
Resolved 17 May 2007
Resolution: Installed visual alarm for all bilge alarms.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 April 2006 Resolved
Place metal banding on wires in aft stateroom.
Due 13 May 2006
Resolved 25 April 2006
Engineering › Pressure Vessel › Relief Valve
Issued 13 April 2006 Resolved
Proper operation and tag for relief valve on air compressor.
Due 13 May 2006
Resolved 25 April 2006
Fire Fighting › Fire Main › Condition
Issued 13 April 2006 Resolved
Repair leak on fire main line leading to anchor wash.
Due 13 May 2006
Resolved 25 April 2006
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2006 Resolved
Renew ring life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 13 April 2006 Resolved
Service hydrostatic release for liferaft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 April 2006 Resolved
Obtain current tide/current tables.
Due 13 May 2006
Resolved 25 April 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 April 2006 Resolved
Place guard around s/w head pump.
Due 25 May 2006
Resolved 2 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 April 2006 Resolved
Service fwd compt fire extinguisher.
Due 13 May 2006
Resolved 25 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 28 January 2005 Resolved
Submit for approval a restoration plan to cover pending repairs to stem, midship, and stern areas.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 29 January 2008
Resolution: Issue resolved prior to 03/31/05 but not cleared from system.
Fire Fighting › Miscellaneous Items
Issued 16 April 2003 Resolved
VSL did not have an updated fire control plan on board during inspection.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 17 April 2003
Resolution: Received fax from VSL with new fire control plan attached.
Lifesaving › Lifejacket/PFD (General)
Issued 16 April 2003 Resolved
Donning placards not posted and need placard for each type of PFD used on board VSL.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 16 April 2004
Electrical › Electric Supply System (service)
Issued 16 April 2003 Resolved
Light guards missing in aft staterooms, engine room, and galley. Replace globes with plastic or place guards over light.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 16 April 2004
Fire Fighting
Issued 8 April 1999 Resolved
Prior to carrying passengers for hire, install fire detection system in engine room.
Condition: Unknown
Due 8 April 1999
Resolved 16 April 1999
Fire Fighting
Issued 8 April 1999 Resolved
Prior to carrying passengers for hire, conduct fire hose test upon completion of new fire pump installation and provide fire/bildge piping drawings.
Condition: Unknown
Due 8 April 1999
Resolved 16 April 1999
Construction/Loadline
Issued 8 April 1999 Resolved
Prior to carrying passengers for hire, make aft engineroom bulkhead airtight.
Condition: Unknown
Due 8 April 1999
Resolved 16 April 1999
Construction/Loadline
Issued 8 April 1999 Resolved
Prior to carrying passengers for hire, install bildge alarms in all watertight compartments.
Condition: Unknown
Due 8 April 1999
Resolved 16 April 1999
Fire Fighting
Issued 8 April 1999 Resolved
Prior to carrying passengers for hire, provide fire extinguisher servicing report to CG.
Condition: Unknown
Due 8 April 1999
Resolved 16 April 1999
Documentation
Issued 19 August 1998 Resolved
PROVIDE MEANS TO ENSURE THAT HAZARDOUS SITUATION REPORTS ARE ADDRESSED FOR CORRECTIVE ACTIONS AND ANALYZED TO IMPROVE SAFETY (ISM 9).
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Lifesaving
Issued 19 August 1998 Resolved
ABANDON SHIP DRILLS ARE NOT BEING COMPLETED IN ACCORDANCE WITH SMS EVERY 3 MONTHS (ISM 8.2)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Lifesaving
Issued 3 April 1998 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR 4 LIFEJACKETS.
Condition: Unknown
Due 4 April 1998
Resolved 4 April 1998
Electrical
Issued 3 April 1998 Resolved
PROVIDE BATTERY COVER FOR PORT ENGINE ROOM BATTERY
Condition: Unknown
Due 4 April 1998
Resolved 4 April 1998
Fire Fighting
Issued 3 April 1998 Resolved
POST SIGN FOR AFT CO2 PULL STATION.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Engineering
Issued 3 April 1998 Resolved
POST SIGN FOR AFT F.O. TANK REMOTE SHUT OFF VALVE
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 3 April 1998 Resolved
CORRECT CHARTS AND PROVIDE UP TO DATE LIGHT LIST.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE SERVICING FOR STBD 25 PERSON LIFERAFT AND HYDROSTATIC RELEASE
Condition: Unknown
Due 1 April 1997
Resolved 7 April 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE 3 LIFEJACKET DONNING PLACARDS.
Condition: Unknown
Due 13 April 1997
Resolved 7 April 1997
Lifesaving
Issued 31 March 1997 Resolved
REPLACE 3 RING BUOYS
Condition: Unknown
Due 13 April 1997
Resolved 2 April 1997
Navigation
Issued 31 March 1997 Resolved
PROVIDE UP-TO-DATE CHARTS AND LIGHT LIST
Condition: Unknown
Due 13 April 1997
Resolved 2 April 1997
Electrical
Issued 31 July 1995 Resolved
PROVIDE SCHEMATIC FOR INSTALLATION OF RECEPTACLE FOR VESSEL'S AIR COMPRESSOR.
Condition: Unknown
Due 25 August 1995
Resolved 12 September 1995
Electrical
Issued 31 July 1995 Resolved
INSTALL RECEPTACLE FOR VESSEL'S AIR COMPRESSOR IN SUCH A MANNER THAT WILL NOT HINDER THE OPERATION OF THE ENGINE ROOM'S VENTILATION DAMPENER, PRIOR TO USING THE COMPRESSOR.
Condition: Unknown
Due 19 September 1995
Resolved 25 September 1995
Documentation
Issued 5 April 1995 Resolved
OBTAIN INTERNATIONAL TONNAGE CERTIFICATE.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 5 April 1995 Resolved
MAKE COLLISION BULKHEAD PENETRATIONS WATERTIGHT.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Documentation
Issued 5 April 1995 Resolved
PROVIDE DOCUMENTATION TO PROVE CURRENT ENROLLMENT IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Electrical
Issued 5 April 1995 Resolved
COMPLETE INSTALLATION OF 12 VOLT LIGHTING WHERE DEAD-END WIRES CURRENTLY EXIST.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Electrical
Issued 5 April 1995 Resolved
MAKE PERMANENT REPAIRS TO ELECTRIC SHORE TIE CONNECTION.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Lifesaving
Issued 30 April 1993 Resolved
PROVIDE EVIDENCE OF 100% ENCLOSED LIFERAFTAGE PRIOR TO SAILING ON AN INTERNATIONAL VOYAGE AND IN NO CASE LATER THAN 30 MAY 93. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Construction/Loadline
Issued 24 May 1991 Resolved
INSTALL QUICK ACTING CLASS 1 WATERTIGHT DOORS IN BULKHEADS AT FRAMES 21 AND 35.
Condition: Unknown
Due 24 May 1991
Resolved 24 May 1991

Casualty record · 3

25 September 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 3858268
17 July 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5191510
21 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6798084
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record