ZODIAC

ZODIAC is a 1924 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in June 2026, along with 14 deficiencies and 3 casualty investigations between 2010 and 2019.

Records from 2010 to 2026. Most recent: inspection, 3 June 2026.

Built
1924
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7937587
WTH5653
Flag
UNITED STATES
Maury page id
psix-57090

Documentation record

Registered dimensions (L × B × D)110.0 ft × 24.6 ft × 18.5 ft
Registered tonnagegross 147 / net 44
ITC dimensions (L × B × D)110.0 ft × 24.6 ft × 18.5 ft
ITC tonnagegross 147 / net 44
BuilderEAST BOOTHBAY, MA, UNITED STATES · built 1924
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELLINGHAM, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 15 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it147 - Convention (Subpart B), Gross Ton
44 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

32 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

3 June 2026 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8344362
2 December 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8276591
4 June 2025 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8152330
11 December 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8046347
26 June 2024 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7941667
13 May 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7911719
21 February 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868515
6 February 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7861813
27 June 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7721226
13 March 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7649144
1 July 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7496900
17 March 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412229
24 June 2021 Exemption
Administrative · USCG Northwest District (dp) · USCG Northwest District (CGD-NW) · Activity 7235279
1 June 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7206702
19 May 2021 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7176886
8 December 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7108730
25 June 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6990821
13 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926305
28 February 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6917833
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809217
21 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6798084
9 April 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6658586
8 April 2019 MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655327
18 March 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6639302
30 March 2018 Internal Structural Exam · COI Inspection · MTSA Verification · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6378693
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360560
6 September 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6265428
31 August 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6256544
13 April 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6124085
6 April 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117191
21 February 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6118653
25 March 2016 Drydock Exam · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840719

Deficiency record · 14

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION THE MARINE INSPECTOR SHALL EXAMINE AND TEST THE FOLLOWING ITEMS TO THE EXTENCT NECESSARY TO DETERMINE THAT THEY ARE IN PROPER OPERATING CONDITION, SAFE ELECTRICAL CONDITION, SAFE ELECTRICAL CONDITION AND FIT FOR THE SERVICE FOR WHICH THEY ARE INTENDED: OVERLOAD OR CIRCUIT PROTECTION DEVICES. CIRCUIT BREAKERS SHALL BE TESTED BY MANUAL OPERATION AND FUSES SHALL BE EXAMINED VISUALLY. THE RATINGS OF FUSES SHALL BE CHECKED TO DETERMINE SUITABILITY OF THE INTENDED SERVICE. BREAKER BOX 'A', CIRCUIT #22/#24 HAD 45 AMP BREAKER WITH 12 AWG CABLE GOING TO AN ELECTRIC MOTOR/PUMP. INSTALL 20 AMP BREAKER AS APPROPRIATE FOR OVERCURRENT PROTECTION. 46 CFR 176.25-15(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 9 June 2026
Resolution: Recieved photo of newly installed breakers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION THE MARINE INSPECTOR SHALL EXAMINE AND TEST THE FOLLOWING ITEMS TO THE EXTENCT NECESSARY TO DETERMINE THAT THEY ARE IN PROPER OPERATING CONDITION, SAFE ELECTRICAL CONDITION, SAFE ELECTRICAL CONDITION AND FIT FOR THE SERVICE FOR WHICH THEY ARE INTENDED: OVERLOAD OR CIRCUIT PROTECTION DEVICES. ELECTRICAL CABLE. THE CABLE SHALL BE EXAMINED AS FAR AS PRACTICABLE WITHOUT UNDUE DISTURBANCE OF THE CABLE OR ELECTRICAL APPARATUS. BREAKER BOX 'B', CIRCUIT #20. THE CABLE LEAVING THE BREAKER BOX HAS BEEN STRETCHED TO THE POINT OF WITHDRAWING THE INSULATION FROM THE CABLE AND EXPOSING THE THREE STRAND CONDUCTORS INSIDE. INSTALL A PROPERLY SIZED CABLE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 176.25-15(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 9 June 2026
Resolution: Recieved photo of newly installed cable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2026 Resolved
THE NUMBER AND IDENTIFICATION OF THE ITEMS STOWED INSIDE, AND THEIR SIZES, MUST BE MARKED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH CONTAINER FOR LIFE JACKETS...IDENTIFICATION OF THE ITEMS MAY BE WORDS OR THE APPROPRIATE SYMBOLS IN IMO RES A.760(18). LETTERS AND NUMBERS MUST BE AT LEAST 2 INCHES HIGH. STORAGE BIN ON DECK FOR CHILD SIZE LIFE JACKETS WERE FOUND WITH OUT THE QUANTITY LISTED AND THE LIFEJACKETS STORED IN THE SALOON WERE NOT PROPERLY LABELED TO EASILY IDENTIFY THEIR LOCATIONS. INSTALL PROPER MARKINGS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 19 June 2026
Resolution: Recieved photos on newly installed labeling.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 June 2026 Resolved
THESE REGULATIONS PRESCRIBE THE MINIMUM STANDARDS, PROCEDURES, AND MEANS TO BE USED TO TEST FOR THE USE OF DANGEROUS DRUGS. PROVIDE EVIDENCE OF ENROLLEMENT IN A CONSORTIUM OR THE MANAGEMENT INFORMATION SYSTEM REPORT. 46 CFR 16.101(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 9 June 2026
Resolution: Recieved documentation of DAPI program.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 June 2025 Resolved
At each inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including...operation of the fire main system and checking of the pressure at the most remote and highest outlets. Fire pump observed leaking and packing overheating during operational test. 46 CFR 176.810(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 24 June 2025
Resolution: Owner provided video of satisfactory operation of the fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 June 2025 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. The current random drug testing program includes six crewmembers. Minimum safe manning for 24-hour operations necessitates eight crewmembers, the program must be revised to ensure all personnel filling these positions are subject to random testing.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 11 July 2025
Resolution: Provided documentation for random drug testing program including eight crewmembers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 2 July 2024
Resolution: O/O provided new radio station license
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2019 Resolved
11118/46CFR180.71/10c - ADULT LIFEJACKETS MUST BE PROVIDED FOR EACH PERSON ONBOARD. VESSEL MAINTAINED 55 SUITABLE ADULT SIZED LIFEJACKETS. PERSONS ONBOARD LIMITED TO 55 UNTIL 4 ADDITIONAL LIFEJACKETS ARE PROVIDED IN ACCORDANCE WITH COI.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: OPERATOR PROVIDED NEW LIFEJACKETS FROM OFFSITE LOCATION PRIOR TO END OF INSPECTION.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2019 Resolved
11118/46CFR155.604(h)/10c - LIFEJACKETS MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL IN ACCORDANCE WITH IMO RES. A.658. ATTACH NEW RETROREFLECTIVE MATERIAL TO 3 ADULT SIZED LIFEJACKETS AND 1 CHILD SIZED LIFEJACKET.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: OPERATOR ATTACHED NEW RETROREFLECTIVE TAPE TO ALL LIFEJACKETS REQUIRING NEW RETRO PRIOR TO THE END OF INSPECTION.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 April 2018 Resolved
Repair gaskets on 03 watertight doors to make water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2018
Resolution: Received pictures illustrating chalk test.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 April 2018 Resolved
Provide updated charts with corrections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2018
Resolution: Rcvd picture of corrected chart.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 April 2018 Resolved
Repair watertight bulkhead penetration in aft bulkhead in space below galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 12 April 2018
Resolution: Rcvd picture of sealed bulkhead penetrations.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 April 2018 Resolved
Conduct monthly tests of rescue boat and EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 23 April 2018
Resolution: Rcvd picture of logs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2018 Resolved
Provide documentation to complete DAPI Program include alcohol test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 26 April 2018
Resolution: DAPI documentation was provided via email.

Casualty record · 3

25 September 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 3858268
17 July 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5191510
21 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6798084
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.