MAURY USCG vessel records
← All vessels

JOSHUA

Built
2002
Last inspected
12 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9804
571218
Flag
UNITED STATES
Maury page id
psix-571218

Documentation record

Registered dimensions (L × B × D)52.0 ft × 17.8 ft × 5.8 ft
Registered tonnagegross 35 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderZIRLOTT BOAT YARD INC · CODEN, AL, UNITED STATES · built 2002
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeShip
Hull configurationMonohull
Hailing portCHERRYFIELD, ME
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Gross Ton
28 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

12 June 2026 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8406312
2 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8226784
11 October 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8017733
29 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8019841
9 October 2023 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7806291
29 June 2022 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7490356
28 March 2022 Hull Examination · Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7419631
14 June 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7225240
28 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7018181
17 July 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6482771
11 June 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6441308
5 March 2018 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6366228
26 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6295642
1 August 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6227575
22 August 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5980033
15 July 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5941709
29 February 2016 Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5824557

Deficiency record · 13

05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 October 2024 Resolved
Missing FCC Safety and Station licenses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2024
Resolved 18 November 2024
Resolution: Witnessed new FCC safety certificate on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 October 2023 Resolved
Inflatable Buoyant apparatus not on vessel, it is listed on COI. O/O to re-install on vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2023
Resolved 11 October 2023
Resolution: Buoyant apparatus properly installed on vessel.
Communications › Alarms/Indicators › High Water Alarm
Issued 11 June 2018 Resolved
Vessel only has one alarm indicator for both High Water Alarms, no indication for which space alarm is activated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2018
Resolved 20 July 2018
Resolution: Ensured both high water level indicators were in proper working order and that each indicator had its own alarm at the operating station.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 June 2018 Resolved
Vessel has no automatic emergency lighting for lounge area below deck. 46CFR184.30-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2018
Resolved 20 July 2018
Resolution: Proper emergency lighting installed.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 August 2017 Resolved
Out dated pubs and directives, update coast pilot, light list, tide and current tables with current version.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 26 October 2017
Resolution: Vessel owner provided current appropriate documentation.
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 9 August 2017 Resolved
Crew members failed to provide proof of enrollment in DAPI program. Prove all crew members are enrolled in DAPI program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 26 October 2017
Resolution: Vessel owner provided current DAPI letter for all employees.
Documentation › Logs/Records › Logbook (official)
Issued 8 August 2017 Resolved
Daily radio checks not logged, log daily radio checks, daily.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 26 October 2017
Resolution: Vessel owner is conducting daily radio checks.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 August 2017 Resolved
Failed to have the vessel undergo a Certificate of Inspection exam before expiration of previous certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 9 August 2017
Resolution: Completed required inspections.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 July 2016 Resolved
Waterlight battery expired. Replace battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Replaced batteries and logged installation in lifesaving maintenance log.
Engineering › Freshwater System (cylinder head cooling) › Valve, Relief
Issued 26 July 2016 Resolved
Waterheater pressure relief valve set at over 100 psi. Replace valve with 100 psi.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Replaced valve with 100 psi relief valve.
Documentation › Logs/Records › Logbook (official)
Issued 26 July 2016 Resolved
No logs found on board. Maintain and provide proper lifesaving and radio logs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Created new radio and lifesaving maintenance logs.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 26 July 2016 Resolved
Emergency Instructions not at operating station. Place Emergency Instructions at ops station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Emergency instructions posted at the operating station.
Engineering › Fuel Oil Service System › Hose
Issued 26 July 2016 Resolved
Fuel line at filter has a kink. Replace or repair fuel line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 22 August 2016
Resolution: Replaced line with new.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.