Inspection history · 21
13 May 2026
Internal Structural Exam · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8372682
6 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8291275
7 April 2025
Internal Structural Exam · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8100755
1 May 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7904358
8 January 2024
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7847491
9 May 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7684790
11 May 2022
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7449820
14 January 2022
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7380125
7 June 2021
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7209047
10 April 2020
DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6939425
16 January 2020
Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6889007
17 July 2019
Deficiency Check · DAPI Audit · Annual Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6745659
19 February 2019
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6631698
16 July 2018
Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6526188
16 June 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6320023
11 February 2018
Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6360423
12 June 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6175771
14 February 2017
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6088365
5 January 2017
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6320030
4 May 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5868969
10 March 2016
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5830490
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 23 Adult PFDs were taken out of service.
Provide 23 adult size PFDs.
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: 23 new adult lifejackets provided
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 April 2025
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b). One (1) 10 B:C extinguisher was placed out of service.
Provide a serviceable 10 B:C fire extinguisher with the appropriate bracket.
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: New 10 B:C extinguisher provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 April 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Provide a valid Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: FCC Safetyradiotelephony Certificate renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2022
Resolved
Shutoff valves installed so as to close against fuel flow must be fitted in fuel supply lines at tank. Existing fuel shutoff valves were found corroded/wasted requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 11 May 2022
Resolution: The shutoff valves were replaced to new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2022
Resolved
Fuel lines must be installed/connected at the top of the fuel tank. Existing fuel supply line fittings at tank top were found corroded/wasted requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 11 May 2022
Resolution: The fittings were replaced to new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2022
Resolved
Flexible fuel lines installed in fuel systems (vital) shall be meet requirements of SAE J-1942. Existing fuel lines for supply and vent betweeen tank and racor fuel filters were found deteriorated requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2022
Resolved 11 May 2022
Resolution: Fuel lines were replaced with approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2019
Resolved
Installed life float was not arranged to "float free". The float was strapped down by two nylon straps with quick release clips.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 31 July 2019
Resolution: Attending Inspector(s) verified life float configuration.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2019
Resolved
Installed life float's retro-reflective markings was worn/required replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 31 July 2019
Resolution: Attending Inspector(s) verified renewal of retro-reflective markings for life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2019
Resolved
"Weak link" for life float was not properly configured. The painter line was not attached to the weak link.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 31 July 2019
Resolution: Attending Inspector(s) verified configuration of painter line for life float.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2019
Resolved
Life float markings (vessels name) was worn/required re-stenciling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 31 July 2019
Resolution: Attending Inspector(s) verified renewal of life float markings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2019
Resolved
Remote fuel shut-off valve linkage was "binding" and not allowing the valve to fully open/close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 26 July 2019
Resolution: Attending Inspector(s) verified operation of fuel shut-off valves.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2019
Resolved
Emergency fuel shut-off valves were not marked properly (missing operating instructions).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 16 January 2020
Resolution: Attending Inspector(s) verified markings for emergency fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 July 2019
Resolved
Electric blower motor for aft compartment was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 16 January 2020
Resolution: Attending Inspector(s) verified renewal of blower motors IWO aft compartment.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 July 2019
Resolved
FCC Radio-Safety Telephony Certificate expired/out of date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 16 January 2020
Resolution: Attending Inspector(s) verified renewal of FCC Radio-Safety Telephony Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 July 2019
Resolved
Marine chart for areas transited were outdated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 16 January 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2018
Resolved
Grab line on ring bouy was deteriorated and in need of replacement. Grab line was whipped into bouy and could not be replaced, whole new buoy needed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 16 August 2018
Resolution: Attending Inspectors verified replacement of ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 June 2018
Resolved
Life float was not properly connected to the vessel via weak link. The painter was found untied.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 July 2018
Resolved 16 July 2018
Resolution: Attending Inspector(s) verified connections between the life float and the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2018
Resolved
Fuel tank flame screens were missing required 30" x 30" mesh.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 16 August 2018
Resolution: Attending Inspector(s) verified correction made to fuel tank flame screens.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2018
Resolved
Type I PFD's (adult/child) were showing signs of deterioration, cracking, and bubbling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 16 August 2018
Resolution: Attending Inspector(s) verified repairs made to Type I PFD's.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 16 June 2018
Resolved
Vessel did not have official number marked on interior structural member of the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 16 August 2018
Resolution: Attending Inspector(s) verified installation/placement of vessels official number on interior stuctural member.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 June 2018
Resolved
Retroreflective material on life float was deteriorated and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 16 August 2018
Resolution: Attending Inspector(s) verified renewal of retro-reflective markings IWO life floats.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 June 2018
Resolved
Vessel did not have a copy of the USCG Navigation Rules of the Road onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2018
Resolved 16 August 2018
Resolution: Attending Inspector(s) verified carriage of USCG Navigational Rules of the Road.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 June 2017
Resolved
Vessel did not have a valid EAP (program) in place or posted on board.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Attending Inspector verified implementation/carriage/posting of EAP (policy)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 June 2017
Resolved
Vessel missing one B:C I extinguisher
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Attending Inspector verified carriage of proper qty/type of portable fire extinguishers on board.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2017
Resolved
Vessel did not carry current/up to date navigation publications (Coast Pilot [name withheld] & USCG Light List).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for areas transited.
Construction/Loadline › Hull › Bracket
Issued 10 January 2017
Resolved
Grind/re-weld fractured weldments IWO port & starboard outboard motor bracket (@ corners due to fatigue)
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 16 July 2018
Resolution: Inspector verified new welds
Engineering › Bilge Water Management System › Hose
Issued 10 January 2017
Resolved
Renew clamps in way of electric submersible bilge pump (aft compartment).
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 11 February 2018
Resolution: Attending Inspector verified installation of new hose clamps IWO bilge discharge piping/hose.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 10 January 2017
Resolved
Properly mount vapor sensor (gasoline) as per manufacturers instructions.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 11 February 2018
Resolution: Attending Inspector verified installation/mounting/replacement of vapor sensor.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 4 May 2016
Resolved
Replace retro.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 11 February 2018
Resolution: Attending Inspector verified replacement of retro-reflective markings on PFD's.