Records from 2002 to 2009. Most recent: inspection, 29 December 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
29 December 2009
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3656413
5 June 2008
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3228164
22 May 2008
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213792
4 June 2007
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2951140
17 May 2006
Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2836840
10 March 2006
Administrative Inspection
Administrative · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2599978
1 June 2005
Re-Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2375862
2 June 2004
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2099292
3 June 2003
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1815743
1 October 2002
Deficiency Check
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1682866
13 August 2002
Deficiency Check
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1658522
17 July 2002
Initial Certification
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1639436
11 March 2002
Simplified Stability Test · Construction Oversight
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1628780
Communications › Visual Communication › Warning Sign (radio room)
Issued 22 May 2008
Resolved
Post emergency broadcast placard.
Condition: Unknown
Due 3 June 2008
Resolved 3 June 2009
Resolution: Emergency broadcast placard information provided on emegency instructions card.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 May 2008
Resolved
Remove unauthorized life vest.
Condition: Unknown
Due 3 June 2008
Resolved 3 June 2008
Resolution: Removed
Fire Fighting › Ventilation Systems › Ducts
Issued 15 June 2004
Resolved
Replace screen on stern with approved flame screen.
Condition: Improper Installation
Due 2 August 2004
Resolved 6 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 June 2004
Resolved
Repair stern light to operate properly.
Condition: Improper/Lack of Maintenance
Due 2 August 2004
Resolved 6 June 2005
Electrical › Electrical Distribution System (service)
Issued 17 July 2002
Resolved
Properly label fuse panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 17 July 2002
Electrical › Electrical Distribution System (service)
Issued 17 July 2002
Resolved
Submit single line electrical drawing to include conductor size, overcurrent protection, and connected loads. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Plans submitted to MSD Peoria.
Electrical › Electrical Distribution System (service)
Issued 17 July 2002
Resolved
Support all wire runs with metal supports every 24 inches. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: All wire runs supported, work completed by crew.
Engineering › Gasoline Engine (propulsion)
Issued 17 July 2002
Resolved
Install bonding strap on gasoline fuel tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Bonding strap installed by vessel crew.
Construction/Loadline › Structures
Issued 17 July 2002
Resolved
Install front gate as per approved Coast Guard plans or provide alternative actions which must be approved by marine inspector. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Gate installed by [name withheld] of Apache.
Construction/Loadline › Hull
Issued 17 July 2002
Resolved
Repair hull damage on stbd pontoon near bow and on stbd side aft. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Repairs made by local contractor.
Lifesaving › Hand Flares
Issued 17 July 2002
Resolved
Provide flares. (6 day/night or 3/3 day and night) LEGACY COMPONENT DESC: Quantity
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Flares purchased by company.
Operations/Management › Drills/Instruction
Issued 17 July 2002
Resolved
Provide on board emergency instructions. LEGACY COMPONENT DESC: Fire
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Copies of instructions printed up by vessel crew.
Engineering › Fuel Oil Service System
Issued 17 July 2002
Resolved
Install fuel tank shutoff valves on fuel tank as per 46CFR182.455(b)(4) and 185.608. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Shutoff valves installed by [name withheld] of Apache Boatworks.
Lifesaving › Buoyant Apparatus
Issued 17 July 2002
Resolved
Provide proper size life ring line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Approved line onboard.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 July 2002
Resolved
Provide plans for alternative compliance for fuel tank compartment regulations as per 46CFR181.400 or comply with said regulations. LEGACY COMPONENT DESC: Ventilation
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Vents installed by [name withheld] of Apache Boatworks.
Navigation › Collision/Grounding Avoidance
Issued 17 July 2002
Resolved
Remove canopy obstruction from stern light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Canopy opened up for stern light.
Lifesaving › Embarkation Appliances/Stations
Issued 17 July 2002
Resolved
Provide ladder for water extraction. LEGACY COMPONENT DESC: Steps
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Ladder purchased by vessel''s company.
Operations/Management › Drug and Alcohol Testing
Issued 17 July 2002
Resolved
Ensure all employees are enrolled in an approved drug testing program and submit record to MSD Peoria. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 13 August 2002
Resolution: Company employees enrolled into Grand Teton Company Program.