Records in 2002. Most recent: inspection, 10 June 2002.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Fire Fighting › Fire Pumps
Issued 10 June 2002
Resolved
#2 FIRE PUMP PRIME PIPE CRACKED AND LEAKING WHEN FIRE PUMP IS PRESURIZED. #1 FIRE PUMP HAS MALFUNCTIONING GUAGE LEGACY COMPONENT DESC: PRIME PIPE
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF ITEM ABOVE.
Engineering › Bilge Water Management System
Issued 10 June 2002
Resolved
SOFT PATCH FOUND ON OIL BILGE CARGO PIPING IWO CARGO PUMP. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO PROPER REPAIR OF ABOVE ITEM.
Engineering › Compressed Air System (control)
Issued 10 June 2002
Resolved
AIR COMPRESSOR PIPING IWO PUMP FOR COOLING SYSTEM LEAKING THROUGH A TEMPORARY REPAIR. MAKE PERMANENT REPAIR LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF THE ABOVE ITEM.
Engineering › Sea-water System (primary cooling)
Issued 10 June 2002
Resolved
SEAWATER SUCTION PIPE IWO PUMP FOR AUC. MACHINERY HAS SOFT PATCH. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF THE ABOVE ITEM.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 June 2002
Resolved
HYDRAULIC HATCH COVER CLOSURE CONTROL IN STBD TUNNEL LEAKS AND THERE IS EXPOSED ELECTRICAL WIRES. REPAIR LEAKS AND EXPOSED WIRES LEGACY COMPONENT DESC: EXPOSED ELECTRICAL WIRES
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF ABOVE ITEM.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 June 2002
Resolved
MISSING PANEL COVER FOR REMOTE SWITCH FOR HYDRAULIC HATCH PUMP LOCATED IN STBD TUNNEL. LEGACY COMPONENT DESC: PANEL COVER
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF ABOVE ITEM.
Deck/Cargo › Holds/Tanks
Issued 10 June 2002
Resolved
HOLE IN DIESEL FUEL VENT ON STBD SIDE LEGACY COMPONENT DESC: DECK VENTS
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: CLASS TO ATTEST TO THE PROPER REPAIR OF THE ABOVE ITEM.
Construction/Loadline › Hull
Issued 10 June 2002
Resolved
ON #1 HOLD FROM BOW: #2, #3, #9 AND #10 HATCH COMBING BRACKETS FRACTURED. ALSO, CLASS TO ATTEST TO REPAIRS TO HATCH COMBING BRACKETS IN SURROUNDING AREAS LEGACY COMPONENT DESC: Bracket
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF THE ABOVE ITEM.
Personnel › Manning/Qualifications
Issued 10 June 2002
Resolved
VESSEL SAILING SHORT OF ONE ENGINEER RATING AS REQUIRED BY MINIMUM SAFE MANNING DOCUMENT. VESSEL REQUIRES A VALID UNMANNED MACHINE SPACE CERTIFICATION AND COULD NOT PRODUCE IT. VESSEL IS NOT TO SAIL UNTIL THE HAVE THIS CERTIFICATE OR AN ADDITIONAL ENGINEERING RATING LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER MANNING.
Navigation › Piloting/Steering
Issued 10 June 2002
Resolved
MANUEUVERING FACT SHEET HAS VESSELS PREVIOUS NAME ON IT AND NO WARNING STATEMENT. UPDATE TO CORRECT NAME AND ATTACH WARNING STATEMENT AS REQUIRED BY 33CFR164.35 LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER PLACEMENT OF WARNING STATEMENT.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 June 2002
Resolved
REFRIDGERATOR STORAGE SPACE FOR VEGETABLES EMERGENCY LATCH IS BROKEN. LEGACY COMPONENT DESC: EMERGENCY ESCAPE LATCH
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 12 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR.