MAURY USCG vessel records Sign in
← All vessels

TAI HARVEST

TAI HARVEST is a 2002 freight ship. The Coast Guard has recorded 16 inspections since 2002, most recently in September 2017, along with 3 deficiencies and 3 operational controls.

Records from 2002 to 2017. Most recent: inspection, 21 September 2017.

Built
2002
Last inspected
21 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9233428 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
572457
Flag
PANAMA
—
Maury page id
psix-572457

Inspections, by type

…with no type recorded6
Years with a record 6 calendar years (2002–2017)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it28615 - Convention (Subpart B), Gross Ton
17654 - Convention (Subpart B), Net Ton
52330 - Dead Weight, Metric Ton
60284 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

21 September 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6271456
19 February 2012 PII Safety Exam · Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4244399
27 December 2008 Ballast Water Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3383960
26 December 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3385215
26 December 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3385421
26 December 2007 ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3118828
21 March 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2892011
24 December 2004 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2247930
25 November 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2252997
29 August 2004 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2180979
19 August 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2171220
12 August 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2164040
12 August 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2165137
11 August 2004 NPV Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2163041
2 March 2004 Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2012020
13 June 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1629138

Deficiency record · 3

Navigation › Piloting/Steering
Issued 14 June 2002 Resolved
Charts not currentl corrected. Vessel must fax copy of purchase reciept of Notice to Mariners to MSO Philadelphia. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2002
Resolution: MSO PHILADLEPHIA RECIEVED COPY OF NOTICE TO MARINERS PURCHASE RECIEPT.
Navigation › Piloting/Steering
Issued 14 June 2002 Resolved
COAST PILOT NOT CURRENTLY CORRECTED. FAX COPY OF PURCHASE RECEIPT OF NOTICE TO MARINERS TO MSO PHILADELPHIA. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2002
Resolution: MSO PHILADLEPHIA RECIEVED COPY OF PURCHASE RECIEPT OF NOTICE OF MARINERS
Navigation › Piloting/Steering
Issued 14 June 2002 Resolved
LIGHT LIST NOT CURRENTL CORRECTED. FAX COPY OF PURCHASE RECEIPT OF NOTICE TO MARINERS TO MSO PHILADELPHIA. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2002
Resolution: MSO PHILADELPHIA RECIEVED COPY OF NOTICE TO MARINERS PURCHASE RECIEPT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.