Records from 1988 to 2019. Most recent: inspection, 28 October 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 57
28 October 2019
Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6846062
8 June 2016
Initial Certification
Physical examination · Commandant (CG-5P-TI) · Activity 5900891
4 May 2016
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5868970
28 September 2011
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4170131
11 January 2011
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3925033
1 September 2010
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3846727
19 December 2008
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3381814
4 May 2008
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3199403
1 April 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3175906
13 December 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3113347
23 March 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2893645
3 March 2006
Drydock Extension
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2595482
14 September 2005
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2492073
25 February 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2299143
15 December 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2258998
29 July 2004
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2145376
16 December 2003
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1964882
8 June 2003
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1812613
20 November 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1708787
14 August 2002
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1663131
22 May 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1619506
19 February 2002
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1487455
5 December 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1412399
3 October 2001
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1074862
16 July 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1069620
11 June 2001
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1066864
3 April 2001
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1059879
5 January 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1429462
14 September 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1423460
17 July 2000
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1472171
14 July 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1472172
13 December 1999
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1395328
2 December 1999
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1462797
22 October 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 804228
9 September 1998
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1445385
26 July 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 52563
24 April 1998
Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1124103
3 April 1998
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 786817
2 April 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 726882
4 December 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 776723
27 August 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 718666
19 August 1997
Inclining Experiment · COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1375004
19 December 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1095801
11 December 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 660708
28 October 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 660709
26 October 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 212018
22 October 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 75374
15 August 1996
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1088669
19 June 1996
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 885597
29 May 1996
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1453237
18 January 1989
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1200086
16 August 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1037479
27 July 1988
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1035258
27 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1200221
20 May 1988
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042053
20 May 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1352396
14 May 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1044137
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 September 2011
Resolved
Coast Pilot outdated, replace as required.
Due 28 October 2011
Resolved 12 October 2011
Resolution: Vessel has access to the internet and demonstrated the ability to access a current Coast Pilot for the area of operation via the internet.
Electrical › Electric Supply System (service) › Cable
Issued 28 September 2011
Resolved
Wires passing through three transverse Aft bulkhead need chaffing materials.
Due 28 October 2011
Resolved 10 October 2011
Resolution: Rubber chaffing materials properly installed to protect the wires passing through the three transverse Aft bulkhead.
Engineering › Steering Gear System › Linkage
Issued 28 September 2011
Resolved
Turnbuckle in the steering system needs cotter pin or locking bolt
Due 28 October 2011
Resolved 12 October 2011
Resolution: Cotter pin installed to secure the turnbuckle in place.
Accommodation/Occupational Safety › Potable Water System › General
Issued 28 September 2011
Resolved
Replace drain line hangers (plastic type) in the presidential suite.
Due 28 October 2011
Resolved 12 October 2011
Resolution: Drain lines secured in place with metal hangers.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 28 September 2011
Resolved
Port side shaft tube stuffing box leaking, tighten as appropriate.
Due 28 October 2011
Resolved 12 October 2011
Resolution: Shaft tube tightened and water seepage significantly reduced.
Construction/Loadline › Structures › Deck Plating
Issued 28 September 2011
Resolved
Several lag bolts in the steering compartment missing nuts, replace as required.
Due 28 October 2011
Resolved 12 October 2011
Resolution: Nuts installed as required.
Fire Fighting › Fire Pumps › Pressure
Issued 28 September 2011
Resolved
Gauge on fire pump is not reading 60 PSI as required, replace with appropriate gauge
Due 28 October 2011
Resolved 12 October 2011
Resolution: New gauge installed, pump tested and a reading of 60 PSI and above observed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 September 2011
Resolved
Wire hangers in the engine room are the plastic type, replace with metal hangers.
Due 28 October 2011
Resolved 12 October 2011
Resolution: Wire hangers replaced with metal type.
Engineering › Bilge Water Management System › Pump
Issued 28 September 2011
Resolved
Machine guard of the starboard side bilge pump/main loose, tighten as required.
Due 28 October 2011
Resolved 12 October 2011
Resolution: Machine guard tighten as required.
Stability › Watertight Integrity › General
Issued 28 September 2011
Resolved
Port light cover in the space forward of the engine room not watertight because of the passage of the washer/dryer ventilation pipe, repair as required.
Due 28 October 2011
Resolved 12 October 2011
Resolution: The space around the washer/dryer ventilation pipe sealed properly.
Construction/Loadline › Hull › Bottom Plating
Issued 28 September 2011
Resolved
Butt block on the port side between frame #91 and #92 leaking water, submit a detailed repair proposal to our office for evaluation and approval prior before carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2011
Resolution: Temporary repairs effected in accordance with repair proposal received, the seams of the Butt block located between frame 91 and 92 stuffed with cotton from the inside of the vessel and seal with marine sealant.
Engineering › Bilge Water Management System › Pump
Issued 1 September 2010
Resolved
Primary bilge pumps on both port & starboard main engine inoperable and unable to draw suction.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2010
Resolution: A new Jabsco 23 gpm pump installed and teste to the satisfaction of the CG Marine Inspector. Note, all of the space were effectively pumped down by the new pump.
Engineering › Steering Gear System › Linkage
Issued 4 May 2008
Resolved
Turnbuckle in steering system got stuck in conduit when vessel went to hard starboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2008
Resolution: Owner made opening to conduit larger to prevent turnbuckle from jamming again.
Construction/Loadline › Penetrations › Gasket
Issued 13 December 2007
Resolved
Replace aft hatch cover gaskets.
Due 31 March 2008
Resolved 1 April 2008
Resolution: Inspected gaskets, all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 December 2007
Resolved
Properly mount anchor light.
Due 31 March 2008
Resolved 1 April 2008
Resolution: Inspected Anchor light, all sat
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 December 2007
Resolved
Provide current Inland Navigation Rules.
Due 31 March 2008
Resolved 1 April 2008
Resolution: Provided copy of inland nav. rules.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 December 2007
Resolved
Label all life jackets with vessel name.
Due 31 March 2008
Resolved 1 April 2008
Resolution: Inspected PFD''s all sat
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 December 2007
Resolved
Provide weathertight container for fire control plan.
Due 31 March 2008
Resolved 1 April 2008
Resolution: Inspected PVC tube for FCP, All sat
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 December 2007
Resolved
Provide retroreflective tape for portside, forward ring lifebuoy.
Due 31 March 2008
Resolved 1 April 2008
Resolution: Inspected ring buoy, all sat.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 14 September 2005
Resolved
Liferaft on STBD side hydrostatic release is expired.
Due 28 September 2005
Resolved 29 September 2005
Resolution: Replaced hydrostatic release with new one.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 December 2004
Resolved
Affix retro-reflective tape on all life rings (buoys)- side opposite vessel lettering.
Due 15 January 2005
Resolved 25 February 2005
Resolution: Retro-reflective tape affixed on all sides of life buoys.
Documentation › Certificates/Documents › FCC SSL
Issued 15 December 2004
Resolved
Provide evidence of valid FCC Radio Safety Certificate. Vessel limited to 1000ft from shore while operating w/ passengers.
Due 15 January 2005
Resolved 25 February 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 2 September 2004
Resolved
Remove/replace rotten floor timber at keelson, located in galley, starboard side, between frames 28-30, prior to 2005 operating season or 31 March 05. Area marked with white chalk.
Due 31 March 2005
Resolved 25 February 2005
Resolution: Floor timber replaced.
Operations/Management › Drug and Alcohol Testing
Issued 16 December 2003
Resolved
Provide proof of enrollment to CG approved drug program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2004
Resolved 22 March 2004
Resolution: Proof of enrollement to valid drug program.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 16 December 2003
Resolved
Post operating instructions locally for the fixed fire system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2004
Resolution: Instructions provided.
Engineering › Bilge Water Management System
Issued 16 December 2003
Resolved
Provide double hose clamps for hoses at thru hull fittings below galley. LEGACY COMPONENT DESC: Hose
Due 15 January 2004
Resolved 22 March 2004
Resolution: Double hose clamps installed.
Operations/Management › Drills/Instruction
Issued 16 December 2003
Resolved
Complete underway emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2004
Resolution: Underway emergency drills completed sat.
Electrical › Lighting (emergency)
Issued 16 December 2003
Resolved
Show operation of all emergency lighting in accommodation spaces
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2004
Resolution: All emergency lighting tested sat.
Communications › Alarms/Indicators
Issued 16 December 2003
Resolved
Show proper operation of engine room bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2004
Resolution: Proper operation demonstrated.
Lifesaving › Lifebuoys
Issued 16 December 2003
Resolved
Provide waterlight with lanyard and non corrosive clip for ring buoy w/line. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2004
Resolution: Lanyard and clip installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 December 2003
Resolved
Post life jacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 22 March 2004
Resolution: Placard posted.
Lifesaving › Inflatable Liferafts
Issued 16 December 2003
Resolved
Show proper configuration of float free arrangement for inflatable life rafts
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2004
Resolution: Showed proper arrangement of life rafts.
Construction/Loadline
Issued 5 May 2003
Resolved
Remove exterior patches on P/S bows to determine extent of plank damage currently being concealed.
Due 25 July 2003
Resolved 2 September 2003
Resolution: Patches removed and planking renewed where there was found to damage. Also area aft P/S planks replaced IWO transitions. All work included in naritive.
Accommodation/Occupational Safety
Issued 24 April 2003
Resolved
Repair wood top railing on P/side of upper deck. Upper deck is restricted to passengers until this item is cleared.
Action required: 705 - Other - as specified
Resolved 5 May 2003
Construction/Loadline
Issued 24 April 2003
Resolved
Present for inspection decking and deck frames under the fwd main deck A/C unit to determine cause of sagging main deck between pantry and main salon.
Due 9 May 2003
Resolved 5 May 2003
Accommodation/Occupational Safety
Issued 15 April 2003
Resolved
Effect permanent repairs to rail stanchions on second deck. Deckis restricted to passengers until this item cleared.
Action required: 705 - Other - as specified
Resolved 24 April 2003
Construction/Loadline
Issued 15 April 2003
Resolved
Remove ceiling on p/s interiors IWO temp repairs on p/s bows for further examination by USCG Marine Inspector.
Due 30 April 2003
Resolved 24 April 2003
Personnel › Manning/Qualifications
Issued 15 April 2003
Resolved
Provide written designation of senior deckhand.
Due 30 April 2003
Resolved 2 September 2003
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 20 November 2002
Resolved
CONDUCT SERVICE AND HYDROSTATIC TEST ON 90 LB HALON, 186 LB HALON, AND CO2 PILOT BOTTLE PRIOR TO CARRYING PASSENGERS. LEGACY COMPONENT DESC: Tanks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 November 2002
Resolved
REPLACE WATERLIGHT ON PORT AFT LIFE RING BUOY AND ATTACH WITH CORROSION RESISTANT CLIP.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 20 August 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 November 2002
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 20 August 2004
Documentation › Certificates/Documents › FCC SSL
Issued 20 November 2002
Resolved
PROVIDE VALID RADIO OPERATOR'S PERMIT.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 20 August 2004
Documentation › Certificates/Documents › FCC SSL
Issued 20 November 2002
Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 20 August 2004
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 20 November 2002
Resolved
PROVIDE HYDROSTATIC RELEASE FOR 10-PERSON INFLATABLE LIFERAFT.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 20 August 2004
Construction/Loadline › Hull › Hull Plating
Issued 14 August 2002
Resolved
Repair as original, port & starboard areas at Bow and Fantail IWO aft cabin. Determine extent of decay damage and make permanent repairs not later than 15 November, 2002. If these repairs are not completed by this date, vessel will be removed from passenger service until completed. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Due 15 November 2002
Resolved 11 September 2004
Accommodation/Occupational Safety
Issued 5 December 2001
Resolved
TIGHTEN RAILINGS ON UPPER DECK STBD SIDE.
Condition: Unknown
Due 5 January 2002
Resolved 11 February 2002
Lifesaving
Issued 5 December 2001
Resolved
PROVIDE ONE ADULT PFD.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Lifesaving
Issued 5 December 2001
Resolved
PROVIDE A MEANS TO LEAVE PASSENGER COUNT WHEN UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 5 January 2002
Resolved 11 February 2002
Documentation › Certificates/Documents › FCC SSL
Issued 5 December 2001
Resolved
PROVIDE FCC MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 5 January 2002
Resolved 15 December 2004
Resolution: Provided FCC Marine Radio Operator permit.
Construction/Loadline
Issued 5 December 2001
Resolved
RENEW/RESTORE STANCHION ON FISH DECK PORT SIDE.
Condition: Unknown
Due 5 January 2002
Resolved 11 February 2002
Navigation
Issued 3 October 2001
Resolved
REPAIR THE STARBOARD STEERING CABLE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Documentation
Issued 11 June 2001
Resolved
PROVIDE A LICENSED MASTER HOLDING A LICENSE EQUAL TO THE VESSEL'S U.S. DOCUMENTED TONNAGE.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Documentation
Issued 3 April 2001
Resolved
PROVIDE A LICENSED MASTER HOLDING A LICENSE EQUAL TO THE VESSEL'S US REGULATORY TONNAGE.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Construction/Loadline
Issued 5 January 2001
Resolved
Vessel is not to carry passengers underway from the pier until further inspection of the iron ballast pigs and hull integrity in the vicinity of the STBD bilge just forward of the engine room.
Condition: Unknown
Due 5 February 2001
Resolved 28 February 2001
Fire Fighting
Issued 14 September 2000
Resolved
PROVE PROPER OPERATION OF THE AUTOMATED FIRE SYSTEM PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 October 2000
Resolved 1 November 2000
Documentation
Issued 14 September 2000
Resolved
PROVIDE A LICENSED MASTER HOLDING A LICENSE EQUAL TO VESSEL'S US REGULATORYTONNAGE.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Documentation
Issued 17 July 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Lifesaving
Issued 17 July 2000
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, CONDUCT A SATISFACTORY FIRE AND MAN OVERBOARD DRILL.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Documentation
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE PROOF OF QUALIFIED CAPTAIN AND CREW.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Lifesaving
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE PROOF OF ANNUAL SERVICE AND PROPER INSTALLATION OF INFLATABLE LIFERAFT.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Electrical
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF BOTH GENERATORS.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Lifesaving
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE LIFEJACKET DONNING INSTRUCTIONS FOR ALL LIFEJACKET STORAGE AREAS.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF MAIN PROPULSION SYSTEM.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPLACE BILGE DISCHARGE LINE IN WAY OF GALLEY BILGE.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Lifesaving
Issued 2 December 1999
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, DEMONSTRATE ABANDON SHIP AND FIRE DRILLS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Fire Fighting
Issued 2 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF FIREMAIN SYSTEM.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 22 October 1998
Resolved
Provide approved flame bowl for fuel filter on stbd generator.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Documentation
Issued 22 October 1998
Resolved
Provide proof of current documentation.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
Provide and post PFD Donning Instruction.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Construction/Loadline
Issued 9 September 1998
Resolved
Make plank & frame repairs to the stbd aft counter area to the satisfactionof the attending CG marine inspector & the cognizant OCMI prior to carryingpassengers.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Engineering
Issued 9 September 1998
Resolved
Make proper repairs to stbd F/O tank gauge glass and auto shutdown device.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Documentation
Issued 19 August 1997
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROPER TRAINING FOR AND DESIGNATE IN WRITING A SENIOR DECKHAND IAW NVIC 1-91.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997
Resolved
POST CERTIFICATE OF DOCUMENTATION ON VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE VALID LICENSES FOR VESSEL CREW._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF DRUG TESTING PROGRAM FOR VESSEL CREW._x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Lifesaving
Issued 19 August 1997
Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT FIRE AND ABANDON SHIP DRILLS IN THE PRESENCE OF A MARINE INSPECTOR, INCLUDING OPERATION OF THE RESCUE BOAT IN THE WATER._x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997
Resolved
VESSEL RESTRICTED TO NOT MORE THAN 1,000 FEET FROM LAND WHEN CARRYING PASSENGERS UNTIL FFC LISENCE IS POSTED ON VESSEL._x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997
Resolved
PRIOR TO CARRYING PASSENGERS, POST STABILITY LETTER ON VESSEL UPON RECEIPT FROM USCG MARINE SAFETY CENTER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Electrical
Issued 19 August 1997
Resolved
PROVIDE APPROVED PLAN FOR WIRING DIAGRAM FOR FIRE CONTROL PANEL._x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997
Resolved
SUBMIT LETTER DOCUMENTING 5 YEARS OF SIMILIAR SERVICE FOR VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 September 1997
Resolved 10 September 1997