Records in 2002. Most recent: inspection, 21 December 2002.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 23 December 2002
No resolution recorded
Reference line not indicated on the Load Line Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Certificates/Documents
Issued 23 December 2002
Resolved
Provide proof of the vessel last two (2) dry-docks. LEGACY COMPONENT DESC: Cargo Ship Safety Construction Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 23 December 2002
Resolved
Vessel to have sewage overboard valve secured and to either have all sewage pumped ashore or provide port-a-toilets for the crew. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Lifesaving › Lifeboat
Issued 23 December 2002
Resolved
Apply retro reflective tape to the underside of the lifeboats. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Resolved 27 December 2002
Lifesaving › Lifeboat
Issued 23 December 2002
Resolved
Install limit switches to both port and starboard lifeboat davits.
Action required: 705 - Other - as specified
Resolved 27 December 2002
Personnel › Certificates/Documents/Licenses
Issued 23 December 2002
Resolved
Provide proof that the crew has submitted the vessel application for endorsements to the vessel Administration. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Operations/Management › Mandatory Ship Reporting Systems
Issued 23 December 2002
Resolved
Arrival notification gave incorrect country of registry. LEGACY COMPONENT DESC: Entry Report
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2002
Resolution: Letter of Warning to be issued to Agent.
Documentation › Certificates/Documents
Issued 23 December 2002
Resolved
Provide original certificates onboard vessel for Coast Guard review.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Deck/Cargo
Issued 23 December 2002
Resolved
Remove propane bottles that are thrown in front of the tractor loaded on the t-ween deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Electrical › Electric Generation Source (emergency)
Issued 21 December 2002
Resolved
Prover proper operation of emergency generator by other than ships power. LEGACY COMPONENT DESC: Power Requirement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 December 2002
No resolution recorded
Place blank cover of hole in electrical panal as a result of mission circuit breaker in panal outside galley port side.
Condition: Improper/Lack of Maintenance
Due 27 December 2002 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service)
Issued 21 December 2002
Resolved
Properly "dead-end" all wire in the battery room. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Navigation › Collision/Grounding Avoidance
Issued 21 December 2002
Resolved
Affix ARPA lable IAW 33 CFR LEGACY COMPONENT DESC: Radar
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Lifesaving › Visual Distress Signals (General)
Issued 21 December 2002
Resolved
Purchase required signal devices IAW SOLAS LEGACY COMPONENT DESC: Missing
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Construction/Loadline
Issued 21 December 2002
Resolved
Place covers on all ballast/void spaces fwd of and aft of bow thruster. LEGACY COMPONENT DESC: Ballast/voild covers
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Electrical
Issued 21 December 2002
Resolved
Secure batteries in battery room behind bridge. LEGACY COMPONENT DESC: Emergency Battery Power Supply for Navigation Equipment
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Lifesaving › Lifeboat Equipment
Issued 21 December 2002
Resolved
Supply and install all required lifeboat equipment. LEGACY COMPONENT DESC: All
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Lifesaving › Launching Appliances
Issued 21 December 2002
Resolved
Prove proper operation of both port and stbd lifeboat davits. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Fire Fighting › Firemans Outfit
Issued 21 December 2002
Resolved
Insure all fire fighting outfits are complete at all locations. LEGACY COMPONENT DESC: Various
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Lifesaving › Lifeboat › Seating
Issued 21 December 2002
No resolution recorded
Make repairs to port lifeboat. Wood on gunwales and fwd seat is rotted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Lifesaving › Lifeboat
Issued 21 December 2002
Resolved
Prove proper operation of both port and stbd lifeboat engines. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Lifesaving › Lifeboat
Issued 21 December 2002
Resolved
Secure fuel tank for both port and stbd engine. LEGACY COMPONENT DESC: Fuel Tank
Due 27 December 2002
Resolved 27 December 2002
Lifesaving › Lifebuoys
Issued 21 December 2002
Resolved
Replace all lifebuoy lights as needed. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 December 2002
Resolved
Secure CO2 fire extinguishers in aft fire locker. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 December 2002
Resolved
Place guard on moving parts on refrigerant pump next to refers. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 21 December 2002
Resolved
Clean flame screens on "Dirty Oil" vent pipes on port side. LEGACY COMPONENT DESC: Ventilation
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 21 December 2002
Resolved
C/R diesel oil fill pipe on stbd bunker station to remove "patch". LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 27 December 2002
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 21 December 2002
No resolution recorded
Remove in-operable "red" P/V on stbd side entrance to control room. P/V appears to have been patch in the past.
Condition: Improper Installation
Due 27 December 2002 — due date passed with no resolution recorded
Fire Fighting › Fire Hoses
Issued 21 December 2002
Resolved
Replace fire hose outside of control room on stbd side. Hose is dry-rotted. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 21 December 2002
No resolution recorded
Replace missing light covers throughout engine room as needed.
Condition: Improper/Lack of Maintenance
Due 27 December 2002 — due date passed with no resolution recorded
Fire Fighting › Nozzles
Issued 21 December 2002
Resolved
Replace/repair fire hose nozzel on fire station just outside of ER control room on stbd side. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 27 December 2002
Resolved 27 December 2002
Engineering › Bilge Water Management System
Issued 21 December 2002
Resolved
Prove proper operation of bilge alarms. Only one detection device located. LEGACY COMPONENT DESC: Interface Detector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Fire Fighting › Fixed Fire Detection System
Issued 21 December 2002
Resolved
Prove proper operation of Fire Detection System throughout vessel. LEGACY COMPONENT DESC: Control Panel
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Engineering › Lubricating Oil Storage/Transfer System
Issued 21 December 2002
Resolved
Make proper repairs to the OWS. LEGACY COMPONENT DESC: OWS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 21 December 2002
Resolved
Replace all required lights on lifejackets as needed. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Operations/Management › Drills/Instruction
Issued 21 December 2002
Resolved
Conduct required fire drill and abandon ship drill in the presence of a Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Fire and Abandon ship drill
Due 27 December 2002
Resolved 23 December 2002
Resolution: Conducted fire drill in galley and lowered starboard lifeboat.
Documentation › Certificates/Documents
Issued 21 December 2002
Resolved
Have class society conduct a re-exam for certification of the Cargo Ship Safety Equipment Certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Due 23 December 2002
Resolved 27 December 2002
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 21 December 2002
No resolution recorded
Vessel is to have an external audit of the Safety Management System.
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Fire Main
Issued 21 December 2002
Resolved
Repair small leak in Fire Main on the stbd side Foc'sle. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2002
Accommodation/Occupational Safety
Issued 21 December 2002
Resolved
Remove and clean spilled fluid in battery room. LEGACY COMPONENT DESC: Spilled fluid
Due 27 December 2002