MAURY USCG vessel records Sign in
← All vessels

FUGRO EXPLORER

FUGRO EXPLORER is a 1999 research vessel. The Coast Guard has recorded 47 inspections since 2002, most recently in September 2024, along with 28 deficiencies, 11 operational controls and 1 casualty investigation in 2013.

Records from 2002 to 2024. Most recent: inspection, 13 September 2024.

Built
1999
Last inspected
13 September 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208564 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
573687
Flag
PANAMA
—
Maury page id
psix-573687

Inspections, by type

…with no type recorded11
Years with a record 15 calendar years (2002–2024)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2925 - Convention (Subpart B), Gross Ton
1981 - Dead Weight, Ton
877 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 47

13 September 2024 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7999390
2 June 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7713006
9 March 2023 PSC B
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7648167
14 February 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7636420
2 November 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7587932
2 September 2022 PSC B
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7549413
7 June 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7470846
27 January 2022 PSC B · Ballast Water Examination
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7386624
1 December 2021 PSC B · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7359990
27 May 2021 PSC B · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7208473
14 April 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7174909
2 November 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7088263
26 July 2020 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7016331
2 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6993524
31 May 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6964584
5 May 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6948450
26 March 2020 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6929489
5 March 2020 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6920334
10 February 2020 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6904868
19 September 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6808771
16 January 2018 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6338686
4 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6332317
30 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6315874
28 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6314126
10 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6230642
27 December 2010 ISPS III Exam · NPV Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3916480
12 March 2010 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3693526
26 June 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3241482
13 May 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2929187
9 April 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2904191
6 April 2007 NPV Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2903210
11 February 2007 ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2870415
3 January 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2850350
9 January 2006 PII Safety Exam · ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2563300
25 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2227114
24 July 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2143614
13 July 2004 ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2131973
12 July 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2195559
28 April 2004 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2054549
29 October 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1938185
25 October 2003 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1942946
15 July 2003 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1859527
27 May 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1802553
5 February 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1742332
30 December 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1724375
14 July 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1649001
19 June 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1631219

Deficiency record · 28

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2021 Resolved
Electricla installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. Found a spliced cable splitting into two heating elemeents servicing the hydraulic steering pumps.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2021 Resolved
Electrtical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. There is an open dead-end cable in the steering space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021 Resolved
machinery shall be so installed addequate for the service they are intended. The #4 diesel generator has a temporary putty repair on the valve cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021 Resolved
Machinery and associated piping and fittings shall be installed to reduce danger to persons on board. Port side main engine bilge well was found with an excessive amount of fuel, and there is excessive oily water in starboard bilge well.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021 Resolved
achinery and associated piping and fittings shall be so installed adequate for the service they are intended. Multiple heat exchange flange connections were missing bolts, and a dirty oil tank cover was also missing bolts.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2020 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY EQUIPMENT AND OTHER ITEMS. THE PORT SIDE PROPULSION SYSTEM IS INOPERABLE. 74SOLAS(14) I/11(b) Action taken 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2020
Resolved 27 July 2020
Resolution: Vessel made effective repairs to the propulsion system with attestation by class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 March 2020 Resolved
Rescue boat shall be capable of maneuvering at speeds up to 6 knots and maneuvering that speed for a period of at least 4 hours. Existing deficiency remains outstanding rescue boat was found with engine operating intermittently, stopping sporadically. 74 SOLAS (CONS 97) III/47.1.5 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2020
Resolved 24 April 2020
Resolution: ENGINE WAS DETERMINED TO BE OPERATING PROPERLY
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 February 2020 Resolved
Rescue boats shall be capable of manoeuvering at speeds up to 6 knots and maintaining that speed for a period of atleast 4h. Rescue boat was found with engine operating intermitently, stopping sporadically. SOLAS 74 (cons 97) III/47.1.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 25 March 2020
Resolution: Rescue boat engine was replaced with a new one and was tested satisfactorily. Pictures and video were provided by the vessel's master via email. Pictures uploaded in MISLE Documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2019 Resolved
Fire Extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed survitec CO2 high pressure system service reports (dated 25 June 2019) indicating the flexible hoses for the CO2 system for the Galley hood and ENG room were fitted/renewed in 1995/1997. Maintenance shall be in accordance with Panama Merchant Marine Circular MMC-226. SOLAS 74(1997)II-2/21 17 ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 September 2019 Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 05 minutes. PSCO observed that the ships crew could not start the rescue boat for approx. 45 minutes due to a dead battery. Furthermore the linkage for the throttle and steering initially malfunctioned when the engine did start. SOLAS 74(1997)III/14.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 20 September 2019 Resolved
Oil filtering equipment ref. to in paragraph one of this regulation shall be of a desgin approved by the administration. Inconsodering the design of such equipment the administration shall have reguard to the specificiation recommended by the organization. PSCO observed flexible hose running from ows to sludge tank. MARPOL ANNEX I/14.6 17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 20 September 2019 Resolved
Oil filtering equipment referenced to in paragraph 1 of this regulation shall be of a design approved by the administration. In considering the design of such equipment the administration shall have regard to the specification recommended by the organization. PSCO observed that the 15ppm bilge alarm does not record and store current data. Alarm was replaced May 2019 and previously recorded data was not available. MARPOL ANNEX I/14.6 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2019
Resolution: The original USB the Chief Engineer pulled data from showed the last power up of the current OWS alarm was 2/17/17 and showed data from 2010-2017. The [name withheld] retrieved another USB and was able to retrieve data as required to satisfaction of CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2019 Resolved
Doors required to be self closing shall not be fitted with hold back hooks. PSCO observed 03 doors in the main ladder well of the vessel with metal hold back hooks SOLAS 74(1997)II-2/47 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2019 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical mechanical flame-retarding and, where necessary fire-resisting properties of the cable. PSCO observed several cable joints were exposed or in disrepair in the engine room and fwd machinery space. SOLAS 74(1997) II-1/45.5.6 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2019 Resolved
Each lifejacket shall be fitted with a whistle firmly secured by a cord. 06 inflatable lifejackets on bridge did not have a whistle. SOLAS 74(1997)III/32.1.6 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2019 Resolved
Each lifejacket shall have a light. PSCO observed 05 out of 06 inflatable lifejackets on the bridge did not have a light. SOLAS 74(1997)III/32.3 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 20 September 2019 Resolved
All ships of 500 GT and upwards shall in addition to meeting the requirements of paragraph 2.3 with the exception of paragraphs 2.3.3 and 2.3.5 and the requirements of paragraph 2.4 have rudder, propeller, thrust, pitch, and operational mode indicators or other means to determine and display rudder angle, propeller revolutions the force and direction of thrust and if applicable the force and direction of lateral thrust and the pitch and operational mode all to be readable from the conning position. PSCO observed 09 rudder angle indicators on the bridge and 02 rudder angle indicators in the steering gear room did not match each other between 03-10 degrees. SOLAS 74(2014)V/19.2.5.4 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 10 August 2017 Resolved
Each administration shall ensure that each member has the appropriate endorsements for their position. The Chief Mate has not applied for a new Flag State endorsement after receiving a new certificate of competency in January 2016. STCW 1/10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Steering Gear System › Rudder
Issued 27 December 2010 Resolved
0936 Vessel is required to have a main steering gear system capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. Vessel's stbd side rudder is stuck at the midship position. Class to attest to the proper operation of the stbd rudder. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2011
Resolution: ABS tested the renewed rudders and said that they were operating properly. See attached class report.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 12 March 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2010
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Steering Gear System › Linkage
Issued 12 March 2010 Resolved
Steering gears linkage used single nut, vessel is required to make changes, i.e. double nut, locknut / washers or cotter pin NLT 12APR10.
Condition: Improper Installation
Due 12 April 2010
Resolved 18 May 2010
Resolution: Lock nuts were installed on all required equipment
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 March 2010 Resolved
Vessel OWS was upgraded from MEPC 60 to MEPC 107. No changes were made on vessel IOPP, Rectify NLT 19Mar10.
Condition: Unknown
Due 19 March 2010
Resolved 18 May 2010
Resolution: IOPP reflected changes.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 6 April 2007 Resolved
Vsl entered port & failed to submit updated NOA.
Due 6 April 2007
Resolved 6 April 2007
Lifesaving › Inflatable Liferafts › Approval
Issued 11 February 2007 Resolved
All Six liferafts expired on 16Jan07. All liferafts shall be inspected or an extension shall be issued by Administration prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2007
Resolution: All liferafts inspected satisfactory by Mobile Ship Chandlery, per Murph @ [phone withheld].
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 February 2007 Resolved
Fire Control Plan is missing EEBD symbol on every plan posted on vessel on both legend and on plan. Vessel to update Fire Control Plan and have it approved by Classification Society.
Due 12 March 2007
Resolved 18 May 2007
Resolution: Corrected plan updated and approved by admin. Fire control plan is not required to be approved by class
Fire Fighting › Fire Hoses › Condition
Issued 28 April 2004 Resolved
Procure and provide receipt of a new, approved fire hose and nozzle for fire station #18 IAW SOLAS 74 ammended, Chapter II-2, Reg 4.7.1 prior to departure from Galveston, TX.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 30 April 2004
Resolution: Vessel is provided with a hose and nozzle.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 April 2004 Resolved
Provide up to date legible fire control plans prior to 29APR04 in accordance with SOLAS 74 Ammended Chapter II-2, Reg 20.
Due 29 April 2004
Resolved 30 April 2004
Resolution: Vessel had thirteen new up to date fire control plans printed.
Personnel › Manning/Qualifications
Issued 30 December 2002 Resolved
Vessel not manned in accordance with Panamanian Safe Manning Certificate. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2003

Casualty record · 1

7 August 2013Routine · role: Acknowledged Pollution Source · activity 4677548
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.