MAURY USCG vessel records
← All vessels

FUGRO EXPLORER

FUGRO EXPLORER is a 1999 research vessel. The Coast Guard has recorded 25 inspections since 2017, most recently in September 2024, along with 18 deficiencies, 5 operational controls and 1 casualty investigation in 2013.

Records from 2013 to 2024. Most recent: inspection, 13 September 2024.

Built
1999
Last inspected
13 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 September 2024
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9208564
573687
Flag
PANAMA
Maury page id
psix-573687

Documentation record

Tonnage as PSIX records it2925 - Convention (Subpart B), Gross Ton
1981 - Dead Weight, Ton
877 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

13 September 2024 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7999390
2 June 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7713006
9 March 2023 PSC B
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7648167
14 February 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7636420
2 November 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7587932
2 September 2022 PSC B
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7549413
7 June 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7470846
27 January 2022 PSC B · Ballast Water Examination
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7386624
1 December 2021 PSC B · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7359990
27 May 2021 PSC B · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7208473
14 April 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7174909
2 November 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7088263
26 July 2020 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7016331
2 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6993524
31 May 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6964584
5 May 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6948450
26 March 2020 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6929489
5 March 2020 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6920334
10 February 2020 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6904868
19 September 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6808771
16 January 2018 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6338686
4 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6332317
30 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6315874
28 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6314126
10 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6230642

Deficiency record · 18

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2021 Resolved
Electricla installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. Found a spliced cable splitting into two heating elemeents servicing the hydraulic steering pumps.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2021 Resolved
Electrtical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. There is an open dead-end cable in the steering space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021 Resolved
machinery shall be so installed addequate for the service they are intended. The #4 diesel generator has a temporary putty repair on the valve cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021 Resolved
Machinery and associated piping and fittings shall be installed to reduce danger to persons on board. Port side main engine bilge well was found with an excessive amount of fuel, and there is excessive oily water in starboard bilge well.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 December 2021 Resolved
achinery and associated piping and fittings shall be so installed adequate for the service they are intended. Multiple heat exchange flange connections were missing bolts, and a dirty oil tank cover was also missing bolts.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2020 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY EQUIPMENT AND OTHER ITEMS. THE PORT SIDE PROPULSION SYSTEM IS INOPERABLE. 74SOLAS(14) I/11(b) Action taken 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2020
Resolved 27 July 2020
Resolution: Vessel made effective repairs to the propulsion system with attestation by class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 March 2020 Resolved
Rescue boat shall be capable of maneuvering at speeds up to 6 knots and maneuvering that speed for a period of at least 4 hours. Existing deficiency remains outstanding rescue boat was found with engine operating intermittently, stopping sporadically. 74 SOLAS (CONS 97) III/47.1.5 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2020
Resolved 24 April 2020
Resolution: ENGINE WAS DETERMINED TO BE OPERATING PROPERLY
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 February 2020 Resolved
Rescue boats shall be capable of manoeuvering at speeds up to 6 knots and maintaining that speed for a period of atleast 4h. Rescue boat was found with engine operating intermitently, stopping sporadically. SOLAS 74 (cons 97) III/47.1.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 25 March 2020
Resolution: Rescue boat engine was replaced with a new one and was tested satisfactorily. Pictures and video were provided by the vessel's master via email. Pictures uploaded in MISLE Documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2019 Resolved
Fire Extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed survitec CO2 high pressure system service reports (dated 25 June 2019) indicating the flexible hoses for the CO2 system for the Galley hood and ENG room were fitted/renewed in 1995/1997. Maintenance shall be in accordance with Panama Merchant Marine Circular MMC-226. SOLAS 74(1997)II-2/21 17 ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 September 2019 Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 05 minutes. PSCO observed that the ships crew could not start the rescue boat for approx. 45 minutes due to a dead battery. Furthermore the linkage for the throttle and steering initially malfunctioned when the engine did start. SOLAS 74(1997)III/14.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 20 September 2019 Resolved
Oil filtering equipment ref. to in paragraph one of this regulation shall be of a desgin approved by the administration. Inconsodering the design of such equipment the administration shall have reguard to the specificiation recommended by the organization. PSCO observed flexible hose running from ows to sludge tank. MARPOL ANNEX I/14.6 17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 20 September 2019 Resolved
Oil filtering equipment referenced to in paragraph 1 of this regulation shall be of a design approved by the administration. In considering the design of such equipment the administration shall have regard to the specification recommended by the organization. PSCO observed that the 15ppm bilge alarm does not record and store current data. Alarm was replaced May 2019 and previously recorded data was not available. MARPOL ANNEX I/14.6 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2019
Resolution: The original USB the Chief Engineer pulled data from showed the last power up of the current OWS alarm was 2/17/17 and showed data from 2010-2017. The [name withheld] retrieved another USB and was able to retrieve data as required to satisfaction of CG.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2019 Resolved
Doors required to be self closing shall not be fitted with hold back hooks. PSCO observed 03 doors in the main ladder well of the vessel with metal hold back hooks SOLAS 74(1997)II-2/47 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2019 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical mechanical flame-retarding and, where necessary fire-resisting properties of the cable. PSCO observed several cable joints were exposed or in disrepair in the engine room and fwd machinery space. SOLAS 74(1997) II-1/45.5.6 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2019 Resolved
Each lifejacket shall be fitted with a whistle firmly secured by a cord. 06 inflatable lifejackets on bridge did not have a whistle. SOLAS 74(1997)III/32.1.6 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2019 Resolved
Each lifejacket shall have a light. PSCO observed 05 out of 06 inflatable lifejackets on the bridge did not have a light. SOLAS 74(1997)III/32.3 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 20 September 2019 Resolved
All ships of 500 GT and upwards shall in addition to meeting the requirements of paragraph 2.3 with the exception of paragraphs 2.3.3 and 2.3.5 and the requirements of paragraph 2.4 have rudder, propeller, thrust, pitch, and operational mode indicators or other means to determine and display rudder angle, propeller revolutions the force and direction of thrust and if applicable the force and direction of lateral thrust and the pitch and operational mode all to be readable from the conning position. PSCO observed 09 rudder angle indicators on the bridge and 02 rudder angle indicators in the steering gear room did not match each other between 03-10 degrees. SOLAS 74(2014)V/19.2.5.4 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Received satisfactory class report attesting to close out of deficiency
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 10 August 2017 Resolved
Each administration shall ensure that each member has the appropriate endorsements for their position. The Chief Mate has not applied for a new Flag State endorsement after receiving a new certificate of competency in January 2016. STCW 1/10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]

Casualty record · 1

7 August 2013Routine · role: Acknowledged Pollution Source · activity 4677548
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record