Inspection history · 23
9 December 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8231951
31 October 2024
Special Consideration · COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026344
19 October 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8082820
16 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7843553
19 December 2023
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7840838
19 November 2023
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7827157
19 November 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7833524
1 November 2023
Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7757105
18 January 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7596973
18 February 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7398271
18 February 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7418825
3 January 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7333620
3 November 2021
In-Service Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7344644
4 November 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7090283
30 January 2020
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6903587
8 November 2019
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6852273
18 October 2019
In-Service Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6831453
17 April 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6684303
26 November 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6580110
22 November 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6284784
15 November 2017
Hull Examination · In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6284799
28 August 2017
Administrative Inspection · Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254128
18 October 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6015197
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 October 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessel has installed power supply ventilation system that does not shutdown when pre-engineered system is activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2024
Resolved 20 November 2024
Resolution: Electric blower wired into fireboy system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 October 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Vessels bilges were found with accumulated oil below the reduction gear and shaft hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2024
Resolved 26 November 2024
Resolution: Oil removed from bilge
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 October 2024
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel first aid kit was missing required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2024
Resolved 26 November 2024
Resolution: New first aid kit onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2024
Resolved
Vessels constructed of wood must provide bilge level alarms in all watertight compartments except small buoyancy chambers. A visual and audible alarm must be provided at the operating station to indicate a high water level in each space. Vessel is constructed of wood and does not have a high level indicator forward of the collision bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 20 November 2024
Resolution: High level indicator installed forward of collision bulkhead.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2024
Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI; On sailing vessels: Rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and connections of the standing rigging. Vessel shall provide copy of approved sail plan to MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 20 November 2024
Resolution: Copies received, uploaded into vessel file.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 31 October 2024
Resolved
On passenger decks of vessels engaged in a ferry or excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be
fitted with Bulwarks; Chain link fencing or wire mesh or equivalent. Vessel may meet new T standards: rails with openings of not more than 4 inches in diameter; or bars,slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Vessels deck rail courses are currently at intervals estimated to be 10 inches. Provide plan prior to installation to Marine Inspector for the installation of rail courses that meet the standard listed above.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2024
Resolved 11 February 2025
Resolution: Deficiency overturned. The existing rail arrangement is considered satisfactory IAW approved reconsideration request. See documents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 January 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessel was not able to perform a proper shutdown of engines using the fire suppression system. Repair fire extinguishing system prior to departure and prior to carriage of passengers to the satisfaction of an attending USCG Marine Inspector. 46 CFR 181.420 (a) (3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2024
Resolution: Witnessed proper operation of Fireboy engine shutdown.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 November 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion while getting underway from the dock due to catastrophic failure of the vessels transmission/reduction gear. Demonstrate proper operation of vessels propulsion to the satisfaction of attending CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 December 2023
Resolution: Demonstrated proper operation of propulsion system
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for dry dock exam due 01 December 2023. Vessel to complete satisfactory dry dock exam prior to carrying passengers. 46 CFR 176.600 (c) (1).
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2023
Resolved 29 December 2023
Resolution: Hull exam for credit drydock conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Sea chests, sea valves, and sea strainers must be opened for examination. On wooden vessels, fastenings may be required to be pulled for examination. Vessel is overdue
for fasteners to be pulled. Vessel must complete
satisfactory fastener pull prior to carrying passengers. 46 CFR 176.610 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2023
Resolved 29 December 2023
Resolution: Fasteners were pulled during hull exam for credit drydock.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 4 November 2020
Resolved
All oceangoing vessels 40' or more must have a garbage management plan. No plan provided. Provide a garbage plan.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 November 2020
Resolved 4 November 2020
Resolution: The master provided a written plan prior to the attending MI departing.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 October 2019
Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Racor filter is leaking red dye diesel. Make proper repair to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2019
Resolved 26 November 2019
Resolution: Installed new brass drain valves on fuel filters. No leaks found.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 18 October 2019
Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Starboard side stanchion located forward is loose. Make proper repair to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 October 2019
Resolved 18 October 2019
Resolution: Stanchion was tightened down and the deficiency was rectified on the spot.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 October 2019
Resolved
Conductors in power and lighting circuits must be No. 14 AWG or larger.
Replace 22AWG conductor for light above stove to satisfaction to attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2019
Resolved 30 October 2019
Resolution: Owner replaced installed new light with appropriate conduit size wiring.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 October 2019
Resolved
Provide plans to unstep mast to OCMI within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 22 November 2019
Resolution: Received plan to unstep mast.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 November 2018
Resolved
Aft bilge high-water alarm was found to have only visual arm and audible alarm was inoperable. Existing vessels after 1999 must have both visual and audible high-water alarms. Provide audible alarm for aft bilge highwater alarm, in addition to the visual alarm.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 November 2018
Resolved 26 November 2018
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 November 2018
Resolved
Found vessel to be missing EPIRB log. EPIRB's monthly test must be documented. Provide appropriate EPIRB log.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 November 2018
Resolved 26 November 2018
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.