MAURY USCG vessel records
← All vessels

MANITOWOC

Built
1926
Last inspected
22 October 2014
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 22 October 2014
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (1994–2014)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WF7303
Flag
UNITED STATES
Tonnage
3080 - Regulatory (Subpart C or D), Gross Ton 3080 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-57422
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

22 October 2014 Internal Structural Exam · Deficiency Check · Administrative Inspection · Load Line/Change of Employment
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5009901
2 May 2003 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1786757
15 October 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 769147
28 September 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 210584
21 October 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 862229

Deficiency record · 5

Construction/Loadline › Penetrations › Weld
Issued 22 October 2014 Resolved
Several areas on the main deck of the barge needed plates to be welded over holes to make the barge weather tight, see the attached survey report for a detailed list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 27 October 2014
Resolution: All items noted above were corrected.
Construction/Loadline › Penetrations › Pipe Flange
Issued 22 October 2014 Resolved
There were several thru penetrations that passed between transverse bulkheads that neeaded to be sealed up by welding plates over the holes prior to issuance of the SVLL permit, see the attached survey report for a complete list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 27 October 2014
Resolution: All penterations were welded up and satisfactory.
Stability › Unintentional Flooding › General
Issued 22 October 2014 Resolved
The following compartments of the barge contained 4-5' of standing water in the bilges, Compt's 5-8 needed to have the water pumped out and re-inspected to ensure the spaces were watertight.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 27 October 2014
Resolution: All spaces were free of standing water upon re-inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 October 2014 Resolved
Several compartment vents on the main deck were siezed up and would not close. All vents to be closed prior to the barge leaving port and made weathertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 27 October 2014
Resolution: All vents were secured.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 October 2014 Resolved
The legacy machinery entrance houses needed to be cut down to the 4' level from the main deck to allow passage under the bridges.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 27 October 2014
Resolution: Houses were cut down, all sat.